Search Result

1 - 10 (15)
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 30.10.2020
4 user(s) found this FAQ helpful

Question:

  • Why can't I create elements?
  • Why can't I move a drawing?
  • Why are elements not created correctly?
  • Why does the program crash when I import a DXF file from the land registry office?
  • Why is the outline of a circumscribed area not detected correctly?
  • Why can't I calculate shadows?
  • Why are elements not displayed correctly in animation?
  • Why are parts of dimension text missing?
  • Why do the contents of the screen suddenly rotate?
  • Why can't I get a preview when I move or copy elements?
  • Why are areas not calculated correctly?




Finding the reason for these problems:

Check whether an offset is set in the project settings (File -> New Project, Open Project-> select the project and open the shortcut menu -> Properties; Allplan 2009 and earlier: Tools -> Options ->Advanced Draft -> Settings). If there are offset coordinates, clear the check box.

Select Tools -> Measure(->)Coordinates.
Click in the middle of the drawing in plan view.
If there are very large values (for example, x/y/z greater than 5000 m), you have found the reason for these problems.

The system has problems calculating and displaying data with very large coordinates. The more data you have with very large coordinates, the greater this effect.



Solution:

  • Click Tools -> Options... -> Desktop environment -> Generaland select Optimize working with large coordinates(Allplan 2009 and earlier: Tools -> Options -> Global Options -> Miscellaneous tab -> Optimize working with large coordinates). After this you must restart Allplan. Otherwise, this setting has no effect.

This is a user setting you must define separately for each user.

  • Usually, the best solution is to move the data towards the Allplan origin. Use the "Move" tool. When Allplan prompts you to specify the target point ("To point"), select Global point in the dialog line. You can find detailed information in the help for Allplan. Look for the Global pointtopic.



Note:

If the data are still not displayed correctly, do the following:
Exit Allplan -> Services application-> Service -> Hotline Tools-> cleanup -> start Allplan.

Download PDF  FAQ_EN_Large_coordinates.pdf
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 17.10.2019
5 user(s) found this FAQ helpful

Allplan from version 2011

Parts of Allplan 2011 have been reprogrammed and are completely new. Allplan uses a graphics library, which has been developed especially for CAD programs and visualization tasks. Depending on the data type and application, the display speed of Allplan is much higher than that of earlier versions, and refresh operations are considerably shorter. What's more, you can create hidden line images in real time.
This new technology is not a one-to-one implementation of the software-based solution in the previous version. Instead, a hardware-based approach is used. When it comes to data processing, the graphics card takes on much of the work. The different behavior of these two technologies that may occur in some parts is inherent. Therefore, the resulting display and refresh operations may differ slightly from what you are used to.



General graphics card requirements for Allplan

To fully exploit hardware acceleration capabilities, you require an Open GL 2.0 and DirectX10 (chip-based) compatible graphics card with 512 MB or more memory. Although Windows XP does not support DirectX10, Allplan only requires the chip-based support of the graphics card to manage the graphics library. OpenGL 2.0 is used in 2D and in visualization windows. These changes employ the latest technology in graphic display, so selecting a capable graphics card, and using the proper drivers is essential.

For more information on graphics card specifications, go to:

http://en.wikipedia.org/wiki/Comparison_of_AMD_graphics_processing_units
http://en.wikipedia.org/wiki/Comparison_of_NVIDIA_graphics_processing_units#Quadro)



Professional graphics cards versus Consumer-Level cards

Graphic card manufacturers typically have different product lines targeted for "gamers" and "professional users". While the hardware setup is very similar in case of both cards, there are key differences in their firmware and driver. "Consumer-Level cards" (such as Nvidia GeForce and AMD/ATI Radeon) are optimized for 3D games and technologically designed for DirectX10, as speed is more important than image quality.
Typically a 3D model in a game contains a low number of polygons with textures applied to them, while in CAD applications polygon count is high, and the image quality of wireframe models or shaded models is more important than navigation speed. Also, professional cards' memory usage is optimized for using multiple application windows, while in gaming this is not relevant.
Another key difference between the two product lines is the way they are delivered and supported. Professional cards (such as Nvidia Quadro and AMD/ATI FireGL/PRO) are built according to the video chip manufacturer's references, so you can always be sure that the driver delivered by the video chip manufacturer (such as Nvidia or AMD/ATI) fits your card.
The manufacturers of Consumer-Level cards (such as ASUS, Sapphire, Gigabyte, PNY and so on) may diverge from the chip manufacturer's references, so their drivers may not be compatible with the chip manufacturer's reference driver. Also, the product life cycle and driver release cycles are much shorter in case of gaming cards, usually 6 months up to 1 year at most and a 1-year warranty period maximum.

Example: comparison of graphics cards

Consumer-Level cards
Professional graphics cards / workstation
Products
Radeon
FireMV
FireGL/Pro
Mobility FireGL/Pro
Markets
  • Private customers: desktop systems and notebook systems
  • Corporate desktop systems
  • Corporate CAD and DCC desktop systems and notebook systems
Applications
  • Home/office publishing, productivity, multimedia, games, Internet
  • Finance, clearance, logistics, airport information displays
  • CAD/CAM/CAE, AEC, DCC, GIS, MI, visual simulation, scientific research/imaging
Certification
  • WHQL certification
  • Industrial applications
  • WHQL certification
  • Professional 3D applications
  • WHQL certification
Operating
systems
  • Windows 98SE / Me / XP
  • Windows Vista,
    Windows 7
  • Windows XP, XP64,Vista, Vista 64, Windows 7, Windows 7 64
  • Linux
Drivers
  • Optimized for DirectX
  • Basic Open GL
  • Optimized and designed for DirectX
  • Optimized and advanced Open GL
Life cycle
  • Available for 1 year on average
  • Available for 2-3 years on average
Support
  • Basic, private customers
  • Direct access to dedicated support by trained technicians
Warranty
  • 1 year
  • 3 years with replacementof components




Professional graphics cards versus Consumer-Level cards

Professional graphics cards differ considerably from "Consumer-Level cards" for private users with regard to specific market segments with special requirements:

  • Extensive application tests and certifications with CAD providers
  • Optimized and advanced support for API as well as further developments
  • Longer product life cycles and availability
  • Direct product support
  • Longer warranty period


Nemetschek Allplan GmbH cooperates with Nvidia und AMD to test graphics card drivers for the Nvidia FX Quadro/ Quadro and AMD/ATI FireGL/ Fire Pro series. These product lines are tested, certified and recommended for Allplan by Nemetschek Allplan Systems GmbH.

For more information on certified graphics cards, go to:

www.nemetschek.eu/info/grafikkarten
www.nemetschek.eu/info/graphiccards

There are four different categories and areas:

Graphics cardApplicationQuality testsStatus
Gaming graphics cards3D GamesTested / not testedNot recommended
    
Professional graphics cards3D basisCertified and recommendedEnd of life
    
Professional graphics cards3D performanceCertified and recommendedEnd of life
    
Professional graphics cards3D high performanceCertified and recommendedEnd of life




Recommended graphics cards for laptops (Windows)

For reasons detailed above, we cannot recommend any specific card and driver combination for laptops. However, there are professional graphics cards available for high-end laptops such as NVidia FX Quadro & Quadro NVidia "M" or AMD/ATI FireGL & FirePro "Mobility".
These graphics cards are just as good as their desktop counterparts.
Laptops with Consumer-Level cards have been tested only briefly and cannot be recommended. We have had bad experience with on-board Intel graphics cards.



Graphics cards drivers for Apple Macintosh

Since Macs come with a default graphics card (on-board or gaming), and the drivers are bundled with system updates, we cannot recommend a specific card.
Graphics cards for MacOsX 10.6 (Leopard) or later and Boot Camp support Open GL 2.0 and DirectX10. Currently, there is only one series that is equipped with a professional graphics card: Mac Pro with NVidia FX4800 for Mac.


Notes for Allplan and Macintosh:

  • There is no provision for a direct installation under Macintosh.
  • Access to Windows must be straight from the Boot Camp installation.
  • For performance reasons, Parallels Desktop cannot be used in conjunction with Nemetschek Allplan.


We kindly ask you to understand that Nemetschek Allplan cannot provide support for Boot Camp installations.



Installing graphics cards drivers (Windows)

Graphics cards only work properly if they have a hardware provider supplied driver (not system built-in driver) installed correctly. It may happen that remnants of a previous installation interfere with the current driver installation. If you experience display issues with the drivers listed below, please "clean-install" the driver again. "Clean-install" means removing all previous driver files before installing a new driver. Unfortunately, a simple uninstall may not efficiently remove all components of a driver. There are tools that can do it, like ATI's cat uninstaller or third-party tools like driver cleaner or driver cleaner pro 1.5.



Graphics card drivers for laptops (Windows)

In most cases, graphic card drivers for laptops are supplied by the laptop manufacturer, and graphic card provider supplied drivers will not install on laptops. This makes it practically impossible for us to test laptop graphics cards. If you are experiencing display issues with your laptop, and your supplier does not offer you a driver update, you might try - at your own risk - to tweak a desktop driver to work on your laptop. Note that this is obviously not encouraged by your laptop supplier.

Download PDF  FAQ_EN_Graphics_cards_for_Allplan.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 23.10.2020
2 user(s) found this FAQ helpful

Problem:

Printing with Windows printer drivers is only possible in a restricted way or not possible at all.



Solution:

Resetting all the files with the default values in question involves several steps.
Work through these steps one after the other and check whether the problem is solved after each step.

Step 1

Check whether you can print a test page.
Start -> Control Panel -> Devices and Printers -> select the printer -> Printer properties -> General tab -> Print Test Page.

If you can print the test page but you still cannot print from Allplan -> step 2.

Step 2

Carry out the cleanprint hotline tool.
Exit Allplan, start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanprint -> OK

If the problem still occurs -> step 3

Step 3

Reset the plastw.dat file.
Exit Allplan, start the Services application and do the following:
Service -> Hotline Tools -> cleanstd: resets CAD defaults -> OK
Information is displayed. Confirm it by clickingOK.
question: would you like to reset all CAD settings? It is essentialthat you clickNo.
A dialog box with a list is displayed. Select the plastw.dat file and confirm by clicking OK.

Now it should be possible to print without any problem.



Note:

You can find up-to-date printer drivers provided by the printers' manufacturers on the Internet.
If you have problems with the printer, please download the current driver and install it.

Hewlett Packard: http://www.hp.com
Epson: http://www.epson.de
Océ: http://www.oce.de
Canon: http://www.canon.de
Brother: http://www.brother.de
Lexmark: http://www.lexmark.de

Download PDF  FAQ_EN_Resetting_Windows_printer_drivers_in_Allplan....
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 28.01.2020
1 user(s) found this FAQ helpful

Question:

Why is Allplan running so slow?


Answer:

Check the following points:

1. Current version
Make sure you work with the current Allplan version.

  • Do the following or ask your system administrator to do this:
    Open Allplan and click the ‘?’ icon in the upper right-hand corner. Click ‘Update Allplan’.
    Select 'Find now'. If Allplan finds updates or hotfixes, download the installation packages.
  • Deactivate the virus scanner while your are installing updates or hotfixes. This might require administrator privileges. Contact your system administrator if you have problems.
  • Right-click the Allplan icon on the desktop. A shortcut menu opens.
    Select ‘Run as administrator’ and click ‘Yes’ to confirm the following message.
    As a result, Windows security settings do not block the installation.



2. System requirements:
Check the hardware and software required for your Allplan computer.

2.a)Download and run the system test.
Check the notes.
https://www.allplan.com/de/system/systemvoraussetzungen/

2.b)Check the Allplan system requirements:
https://www.allplan.com/de/system/systemvoraussetzungen/

2.c)You can find information about graphics cards at
https://connect.allplan.com/de/support/grafikkarten.html

2.d)You can find server operating systems you can use for the central file storage of Allplan at
https://connect.allplan.com/en/faqid/20140924094923.html


3. Hotline tools:
Start the Services application, open the ‘Service’ menu and select ‘Hotline Tools’. To save your settings, select the following tools.

- savestd: Saves user defaults.
- savereg: Saves CAD registry settings.

Start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:

- cleanup: Initializes the display.
- cleanstd: Resets CAD defaults.
- cleanreg: Resets CAD registry settings.

Check whether this has solved the problems.
If this is not so, restore the settings you just saved. To do this, start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:
- reststd: Restores saved user defaults.
- restreg: Restores CAD registry settings.


4. Color scheme selected in Allplan:
Start Allplan, open the ‘View’ menu, point to ‘Toolbars’ and select ‘Customize User Interface’. Open the ‘Customize’ tab and set ‘Color scheme and icon design’ to ‘Windows’.


5. Check the availability of all projects that are not online (if you use Workgroup Manager):
Start Allplan, open the ‘File’ menu and select ‘New Project, Open Project’. Deactivate ‘Check availability of all offline projects’.


6. Virus scanner
Check whether an anti-virus program is running in the background of the computer or server.
If so, reduce protection to "programs only".

Scanning "all files" can take a long time, considerably slowing down your computer when you switch between projects or exit the program.
You can exclude the Allplan installation folders from real-time scanning.When you start the Services application, you can see a list of the folders to be excluded.
You can find more information at
https://connect.allplan.com/en/faqid/20091126145752.html
Changes in the settings of the virus scanner only come into effect when you re-start the computer.


7. Aero desktop effects
Deactivate the Aero desktop effects of Windows.
To do this, open the Control Panel, select ‘Ease of Access’ and go to the ‘Make things on the screen easier to see’ area.
Select the ‘Turn off all unnecessary animations (when possible)’ option.


8. Name resolution on the network
If Allplan takes several minutes to start, name resolution on the network may not work.
To check this, do the following:
Right-click the Windows Start Button, select ‘Run’, type in ‘cmd’, click OK, type in ‘Nslookup’ and press ENTER.
Go to the line following the > character, type in the name of the Allplan data server and press ENTER.
The reply starts with the name and address of the server providing name resolution.
You can find the name and address of the Allplan data server in the second group.
If problems occur, contact your network administrator and ask him or her to configure name resolution correctly.


9. Speed of Allplan projects
Check whether some Allplan projects are slower than other Allplan projects.
Start with the empty project and check whether it is slow too.
After this, select any other Allplan project.

If it is only the current project that is slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


10. Network: checking out Allplan using Workgroup Manager
If you use Allplan with Workgroup Manager, you can check whether the problems are caused by the network. To do this, check out the workstation with the project in question and use the project on the local Allplan workstation.
You can find detailed information on checking out an Allplan workstation using Workgroup Manager in the
Services application. Open the ‘Help’ and select ‘Workgroup Manager’.

After you have checked out the workstation, Allplan no longer accesses the central file storage of the server.
If this has solved the problems, they are caused by the network. In this case, the network must be checked in detail.
Contact your network administrator and ask him or her to do this.

If the project is still slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


11. Log files and system information files
If all the points above do not solve the problems, technical support requires more system information about the computer running Allplan.

  • So, we would be grateful if you could send us a support request (Allplan Hotinfo with Allplan logging).
    To create a support request, start the Services application, open the ‘Service’ menu and select ‘Create support request (Hotinfo)’.
    Several dialog boxes open. Select ‘Technical Support Allplan’ and ‘Enquiry with Allplan logging’. Enter all the data required. Finally, click ‘Finish’.
    Another dialog box opens, prompting you to start Allplan. Click the ‘Start Allplan’ button.
    Allplan starts, logging all processes.
    Try to reproduce the problem as exactly as possible.
    Exit Allplan as soon as possible, reducing the data in the log file to a minimum.
    Then click ‘Next’ to generate the support request with the log file.
    You can find more information about Hotinfo at
    https://connect.allplan.com/en/faqid/20140528094911.html
  • To analyze the Windows system environment, we would ask you to send us the logs created by Windows Event Viewer of your computer.
    To start Windows Event Viewer, right-click the Windows Start Button, select ‘Run’ and type in ‘eventvwr.msc’.
    You can also type in ‘Event Viewer’ in the search box of Windows. This displays the link file to the Windows event logs.
    Using Event Viewer, create *.evtx files for the application log and the system log in the ‘Windows Logs’ area and for the ‘Administrative Events’ log in the ‘Custom Views’ area.


Please send us the files.

Download PDF  FAQ_EN_Allplan_is_running_slow.pdf
Version:  Allplan  | Last modified: 24.02.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I fix bugs in Microsoft .NET Framework components?


Note:

This is a Windows problem. The procedure described is not supported by Allplan. You do this at your own risk.
If you are not sure, give these instructions to your system administrator.


Answer:

Online repairing of .NET Framework up to and including version 4.8

Open the support site of Microsoft:

https://support.microsoft.com/de-de/help/2698555/microsoft-net-framework-repair-tool-is-available

Microsoft provides a repair tool for fixing .NET Framework up to and including version 4.8.

Download the “NetFxRepairTool.exe” file and save it to any folder on the hard drive of your computer; for example, C:\Repair_NetFramework.
Run the repair tool by right-clicking the “NetFxRepairTool.exe” file and selecting “Run as administrator” on the shortcut menu. By doing this, you can bypass Windows User Account Control.
Click “Yes” at the following prompts.
Follow the instructions of the repair tool.

After the repair routine is complete, a log shows you whether fixing .NET Framework has been successful.


Offline repairing of .NET Framework up to and including version 4.8

Download the “NetFxRepairTool.exe” file from

https://support.microsoft.com/de-de/help/2698555/microsoft-net-framework-repair-tool-is-available

In addition, download the necessary resources for fixing .NET Framework.
You can download these files from the support site of Microsoft; go to "Offline support".

Download the two files and save them to any new folder on the hard drive of your computer; for example, C:\Repair_NetFramework.




Open the Command Prompt window as an administrator.

Enter the following commands one after another. Confirm each command by selecting Enter.

cd\ [Enter]

cd Repair_NetFramework [Enter]

NetfxRepairTool.exe /addsource C:\Repair_NetFramework [Enter]




The tool repairs .NET Framework.

After the repair routine is complete, a log shows you whether fixing .NET Framework has been successful.


If this does not repair .NET Framework on your computer, try the .NET Framework cleanup tool on the support site of Microsoft.

Download the .NET Framework cleanup tool from
https://blogs.msdn.microsoft.com/astebner/2008/08/28/net-framework-cleanup-tool-users-guide/

After running the .NET Framework cleanup tool, you must reinstall the .NET Framework components removed by the cleanup tool.



Download PDF  FAQ_EN_Repairing_NET_Framework_up_to_and_including_v...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 25.11.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

What can I do if Allplan does not start?


Answer:


Work through the following steps:

Step 1 - run as administrator
Start Allplan with the ‘Run as administrator’ option.
To do this, right-click the Allplan icon and click ‘Run as administrator’.
If Allplan does not start, go to step 2.

Step 2 - cleanup
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanup -> OK
If Allplan does not start, go to step 3.

Step 3 - cleanstd
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanstd: reset CAD defaults -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the settings:
Services application -> Service -> Hotline Tools -> laststd: restore the last settings -> OK -> OK -> Yes -> OK
Go to step 4.

Step 4 - cleanreg
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanreg: reset CAD registry settings -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the registry settings:
Services application -> Service -> Hotline Tools -> lastreg:restore most recent CAD registry settings -> OK -> OK -> Yes -> OK
Go to step 5.

Step 5 (Allplan 2016 and later)
Restart the Wibu service:
Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.

If Allplan does not start, go to step 6.

Step 6 (Allplan 2016 and later)
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.htmlor on the Nemetschek FTP server ftp://nemhotline:ha37jvg8f@ftp.nemetschek.deat download/General/Wibu/CodemeterRuntime.exe

Start the ‘CodeMeterRuntime.exe’ file.
To do this, right-click this file and select
‘Run as administrator’.
Confirm all messages displayed and the defaults by clicking ‘Next’.
CodeMeter Control Center will be installed afterwards.
If Allplan does not start, go to step 7.

Step 7 - contact Technical Support
Send the following information by email to support.de@allplan.com:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
  5. Allplan 2016 and later -> a screenshot of the Wibu Control Center. To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.


We will contact you.

Download PDF  FAQ_EN_Allplan_does_not_start.pdf
Version:  Allplan 2019 / Allplan 2018  | Last modified: 05.05.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I set up Allplan Share? What are the requirements?


Answer:

1)System requirementsfor Allplan Share

Software required

Allplan Version 2018 or higher

Network infrastructure required

Minimum requirements:

A 20-Mbit/s Internet connection for downloading and uploading data

Recommended setup:

At least a 50-Mbit/s Internet connection for downloading and uploading data

2) Licensing

You have two options to buy the Allplan Share option.

1. You can visit the Allplan Shop at ‘shop.allplan.com’.

Allplan Options -> Allplan Share

a. Specify how many licenses you want to buy and add the Allplan Share option to the cart.

b. Follow the instructions displayed and buy the Allplan Share option.

After you have bought the Allplan Share option, the licenses will be assigned to your Bimplus team. You can manage these licenses using ‘My Account’ - ‘Subscriptions and Users’.

2. You can contact the Allplan sales partner in your area.

3) Assigning licenses

Regardless of how you buy the Allplan Share option, you can manage the Allplan Share licenses in the Allplan Shop. Go to the ‘Subscriptions and Users’ area. As an alternative, you can also manage the licenses on the Bimplus portal. Here, go to the ‘Team members’ area.

Allplan Shop - ‘Subscriptions and Users’

1. Log in to the Allplan Shop and open ‘My Account’.

2. Click ‘Subscriptions and Users’ to see your licenses.

3. Select the Allplan Share option on the tab.

4. You can assign one or more Allplan Share licenses to team members. To do this, select the user in the list and assign the license by selecting the check box. You can remove the license at any time by clearing the check box.

If the list does not include the user to whom you want to assign a license, click ‘Invite new Bimplus team member’, enter the email address of the new team member and select a role.

As soon as the new team member has accepted the invitation, you can find this person in the list.

4) Using Allplan Share

To use the Allplan Share option, you require Allplan 2018. The Workgroup Manager option is not necessary.

Starting a project

You have three options to start an Allplan Share project:

1. You can create a new project and save it on Bimplus by setting the location to BIMPLUS. To create a Bimplus project with Allplan Share content, you require ‘Bimplus team owner’ or ‘Bimplus team admin’ privileges.

2. You can copy an existing Allplan project to Bimplus by selecting ‘Copy to’. You can then share this project with other project partners. This does not affect the source project.

3. You can move an existing Allplan project to Bimplus by selecting ‘Move to’. This moves the source project to Bimplus. As a result, this project is no longer available on the local computer or local network.

5) Managing users and assigning users to the project

Allplan Share is a cloud-based solution. Therefore, Allplan Share uses the Bimplus user management for project collaboration. As a result, Allplan Share is independent of local user management systems like Workgroup Manager.

After you have copied or moved an existing Allplan project to Bimplus, you must reassign the users to this project. Otherwise, they cannot access this project.

To define the project members, use the Bimplus project administration. In addition, you must invite new project members to the Bimplus project.

If these Bimplus project members are to use the Allplan Share option too, you must assign an Allplan Share license to each member in advance (as described in ‘3) Assigning licenses’).


Download PDF  FAQ_EN_Allplan_Share.pdf
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 17.12.2015
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I move NemSLock Server to a new server?



Answer:

Reinstalling NemSLock Server

  • Select one of the temporary license files for NemSLock server (for example, 1234567a_001_psd.nslsrv). These licenses are valid for 30 days. However, each license includes only one seat of each configuration purchased. The full number of seats purchased will be available to you as soon as you have installed the registered licenses (see below). If you purchased a configuration for one seat only, you will, of course, receive only one temporary license.
  • When you opt for the “Custom” setup type, you can choose between the following program features:
    Console
    You can use this program to administer NemSLock Server. The console can be installed on several workstations. This way, you can administer the server from a number of different locations. However, you can only connect one console to the server at any one time.
    Server
    The actual license server.
    Logviewer
    This tool analyzes the log files of NemSLock Server.
    User List Generator
    You can use this tool to create the users for NemSLock Server from a text file or based on a server.
    By default, Setup installs all these features.
  • If your license includes configurations for several seats, you need to install the additional temporary license files for NemSLock server after the installation (see below).


Transferring the user administration from the old server (if users are available)

  • You can find the user administration in the program folder of the license server. Copy the "users.mcf" file to the program folder of the new license server.
  • Stop the license server service on the new server before you copy the file. To do this, start the "stopService.bat" program, which is also in the program folder of the license server.
  • After copying, start the license server service again. To do this, use the "startService.bat" program.


Returning the registered licenses

  • Open NemSLock 2006 Server Console on the old server by clicking the icon on the desktop or Start -> (All) Programs -> NemSLock 2006 Server -> NemSLock 2006 Server Console.
  • Click "Stop server".
  • Click "Modules".
  • Click "Transfer license permanently".
  • Confirm the following dialog boxes. Click “Browse”.Windows Explorer starts and opens the folder with the hcws-format file. Now you can use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer with Internet access and so on.Send this file by email to register@nemetschek.de.
  • We will send you an email, confirming that we have received the licenses.
  • You always have to return all licenses.
  • After you have done this, they are only valid for two more days.


Registering the license(s) on the new server

  • Open NemSLock 2006 Server Console on the new license server.
  • Click "Modules" on the left.
  • Select the seat you want to register. If your license contains configurations for several seats, read the notes further down.
  • Click "Registration request (register.txt)".
  • Click "Edit".
  • Fill out all fields marked with an asterisk (*). Make sure you enter your email address correctly, because the registered license file will be sent to this address (and not to the address of the person who sent the registration request!). Click OK to confirm.
  • Click "Create registration request".Windows Explorer starts and opens the folder with the "register.txt" file. Now you can use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer with Internet access and so on.Send the registration request by email to register@nemetschek.de.


If your license includes configurations for several seats, you must send a separate registration request for each seat. You will then receive a registered license file for each seat. You must install each file.

How to install licenses

  • Open NemSLock 2006 Server Console.
  • Click "Stop server" on the left.
  • Click "Modules" on the left.
  • Click ”Browse” to navigate to the registered license file.
  • Click "Install license file".
  • After this, you can start the server again by clicking "Start server".


Configuring the clients

  • Now you need to change each client to the new license server.
  • Click Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager.
  • If the license server window is hidden, click "Configure NemSLock Server"at the bottom. It is a good idea to lock this window. All you need to do is click the drawing pin icon.
  • Enter the computer name or IP address of the license server in the empty box. Then click the "Update” icon to the right.
  • Now the user can select one of the seats provided. Click "Close" to complete the configuration. Now you can start Allplan.
  • After having successfully connected to the license server, clear the check boxes for the trial licenses in the area at the top.


Notes:

  • If a user selects several configurations for a seat and starts Allplan, the license server will provide the required licenses; in other words, starting Allplan once might require two licenses. Consequently, fewer licenses are available to other users.
  • 2014-1 and later: If the latest version of License Manager is installed (file version 1. 0. 26. 153 or later, see License Manager- Options- System), you can also select several licenses. If one of the selected licenses is currently being used by someone else, the program will automatically select the next available license.
  • Clients communicate with the server by TCP/IP via port 10977. So you need to configure the firewall accordingly.
  • The license server and the licenses are downward compatible; they can be used in conjunction with older Allplan versions.
Download PDF  FAQ_EN_Moving_NemSLock_Server_to_a_new_server.pdf ...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011 / Allplan 2009  | Last modified: 22.01.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I remove NemSLock completely from a computer?



Answer:

Do the following:

  1. Uninstall Softlock 2006 by clicking Start -> Control Panel -> Programs and Features.

  2. Select "Nemetschek SoftLock 2006" and then click "Uninstall/Change". Select "Remove" -> Next -> Yes.
  3. Extract the "NSLFixer2006.zip" file attached and copy it to any folder on your computer. If your email provider or firewall software has blocked this file, you can also download it from our webdrive. Use this link:

    https://webdrive.allplan.com/index.php/s/4LrjrymoxESzC6p

    The tool "NSLFixer2006.exe" is under Allgemein/Nemslock

    (click on the right hand side next to file size on the three dots and chose 'herunterladen')

  4. Start NSLFixer2006.exe by double-clicking it.
    Important note:
    If you are running Windows Vista or a newer operating system, click the program with the right mouse button and select "Run as administrator". Confirm the following message.
  5. Create the key by clicking "Generate/Enter a key" (1).

  6. Select the line to the right of "Generate/Enter a key" (2), "1F02E74917D3F6E7348C1F02E74917D35E2599A254864A233C549A25ADD2EDFD", for example, and press "Ctrl+C". Paste this key into an email and send it to "support.de@allplan.com".
  7. We will send you another key. Please copy this key to the second line (3). If you need to restart the program, paste the key you created into the first line (see step 3, do not click "Generate/Enter a key" again!). Then click "Validate twin key" (4). After you have done this, you should see the following message: "System cleaned. Reinstall NemSLock".
  8. Update your current Allplan version. Use the temporary license file ("psd" can be found in its file name). You can also find your current temporary licenses at www.connect.allplan.com. Go to "Profile -> License administration".
    Students should use the Allplan Setup program which they can download from Allplan Campus (http://www.allplan-campus.com -> log on -> select "Software" at the top -> download Allplan). Use the trial license provided by Setup.



After this, request a new license by sending a new registration request (Services application -> Utilities -> License -> License Manager). Select the license entry for your seat and click "Request license".
If you work with a license server, reconnect the client with the server.

Download PDF  FAQ_EN_Removing_NemSLock_completely.pdf Download NSLFixer2006_EN.zip
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 23.09.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Why is it not possible to clear the check box for 'Find license server automatically' and why can't I enter an additional server name? These functions are grayed out.


Answer:

This problem is caused by Windows access rights. Only administrators can change these options.

Installing Allplan:
If this problem occurs during Setup and you cannot select a license, start by installing Allplan as a viewer.

Granting permissions later:
Assign full control to the users.
Local permissions prevent them from accessing the following file: Lic3LM.ini

Check whether the users have full control of the following folder:
Click folder with the right mouse button -> Properties -> Security -> Edit -> select the user - > grant full control

C:\ProgramData\Nemetschek(hidden file)

Open the 'License settings' dialog box: Services application -> Utilities -> License settingsYou should now be able to clear the check box and enter additional server names.

Download PDF  FAQ_EN_Finding_license_server_automatically_or_enter...