Результат поиска

1 - 10 (12)
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 30.09.2020
3 user(s) found this FAQ helpful

Question:

How can I work from home with Allplan without a direct LAN connection to a common file storage folder?



Answer:

1. Working from home with direct access to the central data


If you want to work together on projects, you can use Allplan Share, Allplan’s cloud solution, to work with Allplan without a LAN connection to the central file storage folder. This is only possible if Allplan is installed as a standalone version on a computer without access to a central file storage folder; otherwise, Allplan does not start. If the computer is part of a workgroup installation, the computer must be checked out and used outside the LAN (like a standalone workstation). Data access is via cloud services.
This is only possible if you use Allplan Share for cloud storage.

Working with Allplan Share is just as simple as working at a standalone workstation. You and several other users can access and edit a project at the same time.

To get more information on Allplan Share, use the following link or contact your sales partner:

https://www.allplan.com/de/add-ons/allplan-share/


You can also find further information on Allplan Connect; use the following link:


https://connect.allplan.com/de/forum/themen/topic/topics/cad-allgemein-1/moderierter-sammelbeitrag-zugriff-auf-allplan-projekte-aus-dem-homeoffice-via-allplan-share.html


Note:

VPN is not useful for common project storage.
Allplan exchanges many files with the data server. VPN uses advanced encryption, which considerably slows down data transfer.
A connection via VPN is not approved for Allplan because data might get damaged even if the connection is interrupted only briefly. In addition, working over the internet is extremely slow if the internet connection is not fast enough (at least 100 Mbit).
Allplan does not support a VPN connection with IPv6; Allplan detects only IPv4.
Make sure that the VPN connection does not switch to sleep mode.

Please note that we cannot provide support for this constellation.



2. Working from home without access to the central file storage (working locally):



2.1 Allplan with workgroup manager:

If workgroup manager is included in your license, you can check out a computer or laptop with projects from the workgroup environment. You can then work from home without access to the server. The projects on the computer or laptop that is checked out are locked for the CAD users on the network. These users see the comment you entered when you checked out the computer.

You can find instructions at

https://connect.allplan.com/en/faqid/20160923105251.html

When you use a license server, you can get the license via a VPN connection or borrow the license beforehand:

https://connect.allplan.com/en/faqid/20180109095437.html
https://connect.allplan.com/en/faqid/20160523165423.html




2.2 Allplan without workgroup manager:

Using the office computer
If you have neither workgroup manager nor network access, you must uninstall Allplan and install it again by specifying the local paths. To work with a project, you must back it up and then import it to the local installation.

Using a new (private) computer
If you want to use a new computer to work from home, you must return the license at the office computer and then use this license to install Allplan on the new computer.


We recommend that you do not mix data from the office computer and the private computer. Merging data later involves considerable time and effort.

Use the following link to find out how to transfer projects:

https://connect.allplan.com/en/faqid/20180507154505.html

Загрузка PDF  FAQ_EN_Working_with_Allplan_from_home.pdf
Версия:  Allplan 2019  | Последнее изменение: 12.11.2018
Not voted yet. Be the first to vote this FAQ as helpful!

Information:

This document provides further information on installing Allplan 2019.

Backing up and archiving data:

We strongly recommend that you back up and archive all your data before you upgrade to Allplan 2019.


How to install


You can find detailed instructions on how to install Allplan 2019 in the following places:

- After you have downloaded and unzipped Allplan 2019, you can find the ‘install.chm’ file in the following folder: C:\Users\Public\Documents\Allplan 2019\HelpFiles\English.

- Use the following link:
https://webdrive.allplan.com/s/4LrjrymoxESzC6p and open the General\Installation help\2019 folder.


Please read these instructions before you install Allplan 2019.

System requirements for Allplan 2019

https://connect.allplan.com/en/faqid/20180608093815.html

How to handle licenses when upgrading to Allplan 2019

https://connect.allplan.com/en/faqid/20180608092654.html



Some notes on installing Allplan 2019

If you want to switch from Allplan 2016/2017/2018 to Allplan 2019, you can choose between three installation options. We recommend using the second option: first-time installation and copy data from Allplan 2016/2017/2018.

1. First-time installation

This option installs Allplan 2019 to a new folder without affecting any other Allplan installation (2018 or earlier). Setup does not transfer any data or settings to the new installation.

If you want to transfer data later, you have the following options:

You can uninstall Allplan 2019 and then upgrade from Allplan 2016/2017/2018.
You can integrate the data manually (requires administrative knowledge).

2. First-time installation and copy data from version

This option installs Allplan 2019 to a new folder without affecting any other Allplan installation (2018 or earlier). You can configure Setup to automatically copy the office standard (\std), projects (\prj) and user data (\usr) from Allplan 2016/2017/2018 to the new installations folder.
This duplicates the data: You can use all projects, defaults and resources both in Allplan 2018 and in Allplan 2016/2017/2016. This way, you can test the new version without losing your 'old' Allplan version.
Bear in mind, though, that you should not mix data from different versions. Merging data later involves considerable time and effort.

2a. Continue with first-time installation and copy data from version

This option is available when you have already used the second installation option to install <Product_Version> to a computer that accesses the same data server. As a result, the data are already available.

3. Upgrade and transfer data from Allplan 2016/2017/2018

This option installs Allplan 2019 to an existing folder, converting Allplan 2016/2017/2018 to Allplan 2019 and transferring all important settings. Afterwards, you can no longer work with Allplan 2016/2017/2018.
This does nor affect earlier Allplan versions (Allplan 2015 or earlier).


Installing on a network:

  • If you work in a network environment (one common central file storage folder), you must upgrade all workstations to Allplan 2019. Beforeyou start installing, make sure that all workstations can be upgraded. For technical reasons, it is not possible to mix installations of different major releases. Any related problems area not covered by service contracts.
  • During the upgrade, Allplan 2016/2017/2018 must not be running on any workstation.
  • When installing with Workgroup Manager, make sure all workstations are checked in before you start upgrading.





Converting the data:

Data from earlier Allplan versions need to be converted to version 2019. Allplan 2019 automatically converts the data of a project you open. Click here for instructions on how to convert all projects in a single operation:

https://connect.allplan.com/en/faqid/20090408124904.html


IBD 2019

Click here for instructions on how to get your activation codes for Allplan IBD:

https://connect.allplan.com/en/faqid/20110912113530.html

Загрузка PDF  FAQ_EN_Hotletter_2019.pdf
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Последнее изменение: 17.10.2019
5 user(s) found this FAQ helpful

Allplan from version 2011

Parts of Allplan 2011 have been reprogrammed and are completely new. Allplan uses a graphics library, which has been developed especially for CAD programs and visualization tasks. Depending on the data type and application, the display speed of Allplan is much higher than that of earlier versions, and refresh operations are considerably shorter. What's more, you can create hidden line images in real time.
This new technology is not a one-to-one implementation of the software-based solution in the previous version. Instead, a hardware-based approach is used. When it comes to data processing, the graphics card takes on much of the work. The different behavior of these two technologies that may occur in some parts is inherent. Therefore, the resulting display and refresh operations may differ slightly from what you are used to.



General graphics card requirements for Allplan

To fully exploit hardware acceleration capabilities, you require an Open GL 2.0 and DirectX10 (chip-based) compatible graphics card with 512 MB or more memory. Although Windows XP does not support DirectX10, Allplan only requires the chip-based support of the graphics card to manage the graphics library. OpenGL 2.0 is used in 2D and in visualization windows. These changes employ the latest technology in graphic display, so selecting a capable graphics card, and using the proper drivers is essential.

For more information on graphics card specifications, go to:

http://en.wikipedia.org/wiki/Comparison_of_AMD_graphics_processing_units
http://en.wikipedia.org/wiki/Comparison_of_NVIDIA_graphics_processing_units#Quadro)



Professional graphics cards versus Consumer-Level cards

Graphic card manufacturers typically have different product lines targeted for "gamers" and "professional users". While the hardware setup is very similar in case of both cards, there are key differences in their firmware and driver. "Consumer-Level cards" (such as Nvidia GeForce and AMD/ATI Radeon) are optimized for 3D games and technologically designed for DirectX10, as speed is more important than image quality.
Typically a 3D model in a game contains a low number of polygons with textures applied to them, while in CAD applications polygon count is high, and the image quality of wireframe models or shaded models is more important than navigation speed. Also, professional cards' memory usage is optimized for using multiple application windows, while in gaming this is not relevant.
Another key difference between the two product lines is the way they are delivered and supported. Professional cards (such as Nvidia Quadro and AMD/ATI FireGL/PRO) are built according to the video chip manufacturer's references, so you can always be sure that the driver delivered by the video chip manufacturer (such as Nvidia or AMD/ATI) fits your card.
The manufacturers of Consumer-Level cards (such as ASUS, Sapphire, Gigabyte, PNY and so on) may diverge from the chip manufacturer's references, so their drivers may not be compatible with the chip manufacturer's reference driver. Also, the product life cycle and driver release cycles are much shorter in case of gaming cards, usually 6 months up to 1 year at most and a 1-year warranty period maximum.

Example: comparison of graphics cards

Consumer-Level cards
Professional graphics cards / workstation
Products
Radeon
FireMV
FireGL/Pro
Mobility FireGL/Pro
Markets
  • Private customers: desktop systems and notebook systems
  • Corporate desktop systems
  • Corporate CAD and DCC desktop systems and notebook systems
Applications
  • Home/office publishing, productivity, multimedia, games, Internet
  • Finance, clearance, logistics, airport information displays
  • CAD/CAM/CAE, AEC, DCC, GIS, MI, visual simulation, scientific research/imaging
Certification
  • WHQL certification
  • Industrial applications
  • WHQL certification
  • Professional 3D applications
  • WHQL certification
Operating
systems
  • Windows 98SE / Me / XP
  • Windows Vista,
    Windows 7
  • Windows XP, XP64,Vista, Vista 64, Windows 7, Windows 7 64
  • Linux
Drivers
  • Optimized for DirectX
  • Basic Open GL
  • Optimized and designed for DirectX
  • Optimized and advanced Open GL
Life cycle
  • Available for 1 year on average
  • Available for 2-3 years on average
Support
  • Basic, private customers
  • Direct access to dedicated support by trained technicians
Warranty
  • 1 year
  • 3 years with replacementof components




Professional graphics cards versus Consumer-Level cards

Professional graphics cards differ considerably from "Consumer-Level cards" for private users with regard to specific market segments with special requirements:

  • Extensive application tests and certifications with CAD providers
  • Optimized and advanced support for API as well as further developments
  • Longer product life cycles and availability
  • Direct product support
  • Longer warranty period


Nemetschek Allplan GmbH cooperates with Nvidia und AMD to test graphics card drivers for the Nvidia FX Quadro/ Quadro and AMD/ATI FireGL/ Fire Pro series. These product lines are tested, certified and recommended for Allplan by Nemetschek Allplan Systems GmbH.

For more information on certified graphics cards, go to:

www.nemetschek.eu/info/grafikkarten
www.nemetschek.eu/info/graphiccards

There are four different categories and areas:

Graphics cardApplicationQuality testsStatus
Gaming graphics cards3D GamesTested / not testedNot recommended
    
Professional graphics cards3D basisCertified and recommendedEnd of life
    
Professional graphics cards3D performanceCertified and recommendedEnd of life
    
Professional graphics cards3D high performanceCertified and recommendedEnd of life




Recommended graphics cards for laptops (Windows)

For reasons detailed above, we cannot recommend any specific card and driver combination for laptops. However, there are professional graphics cards available for high-end laptops such as NVidia FX Quadro & Quadro NVidia "M" or AMD/ATI FireGL & FirePro "Mobility".
These graphics cards are just as good as their desktop counterparts.
Laptops with Consumer-Level cards have been tested only briefly and cannot be recommended. We have had bad experience with on-board Intel graphics cards.



Graphics cards drivers for Apple Macintosh

Since Macs come with a default graphics card (on-board or gaming), and the drivers are bundled with system updates, we cannot recommend a specific card.
Graphics cards for MacOsX 10.6 (Leopard) or later and Boot Camp support Open GL 2.0 and DirectX10. Currently, there is only one series that is equipped with a professional graphics card: Mac Pro with NVidia FX4800 for Mac.


Notes for Allplan and Macintosh:

  • There is no provision for a direct installation under Macintosh.
  • Access to Windows must be straight from the Boot Camp installation.
  • For performance reasons, Parallels Desktop cannot be used in conjunction with Nemetschek Allplan.


We kindly ask you to understand that Nemetschek Allplan cannot provide support for Boot Camp installations.



Installing graphics cards drivers (Windows)

Graphics cards only work properly if they have a hardware provider supplied driver (not system built-in driver) installed correctly. It may happen that remnants of a previous installation interfere with the current driver installation. If you experience display issues with the drivers listed below, please "clean-install" the driver again. "Clean-install" means removing all previous driver files before installing a new driver. Unfortunately, a simple uninstall may not efficiently remove all components of a driver. There are tools that can do it, like ATI's cat uninstaller or third-party tools like driver cleaner or driver cleaner pro 1.5.



Graphics card drivers for laptops (Windows)

In most cases, graphic card drivers for laptops are supplied by the laptop manufacturer, and graphic card provider supplied drivers will not install on laptops. This makes it practically impossible for us to test laptop graphics cards. If you are experiencing display issues with your laptop, and your supplier does not offer you a driver update, you might try - at your own risk - to tweak a desktop driver to work on your laptop. Note that this is obviously not encouraged by your laptop supplier.

Загрузка PDF  FAQ_EN_Graphics_cards_for_Allplan.pdf
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012  | Последнее изменение: 30.01.2020
1 user(s) found this FAQ helpful

Task:

You have installed Allplan on several local workstations. Now you want to change the installation so that you can access a common network drive.



Note:

Before you switch to a network installation, it is essential that you back up all the data of all the workstations.
We strongly recommend that you take advantage of the expertise of Nemetschek’s technical support staff. We are happy to help you!



Solution:

The following description shows how to change several workstations where Allplan is installed locally and the project data is also stored locally on each computer to workstations with a common network drive without Workgroup Manager.

1st - getting ready
Choose one of the workstations where you will install all the projects and the office standard (hereinafter referred to as the main workstation).
First, move all the projects to the main workstation.

1.a: copying resources into projects
To make sure that the projects in your office have a uniform appearance, change the path settings for the projects' resources to 'Project'.
Make the following setting for each project:
Allplan -> File menu -> ProjectPilot - Admin -> select the individual projects one after the other -> right mouse button -> Properties -> Settings tab
Set the path settings for 'Pen and line definitions', 'Fonts', 'Patterns, hatching styles, area styles', 'Bar and mesh cross-section catalogs', 'Layer structures, line styles, drawing types' and 'Attributes proposed' from 'Office' to 'Project', if necessary.
The corresponding elements are copied from the office standard directly to the project. This ensures that the project settings stay the same even when you copy the project to the new server with the new office standard.

1.b: same folder name as project name
Open the 'General' tab and select the 'Same folder name as project name' setting if you want to proceed as described in 2b.

1.c: pen color ("Color stands for pen")
The pen color for the "Color stands for pen" setting is a user-specific setting that is not saved in the project but in the user folder (...\Usr).

2.a: backing up projects of the individual workstations and importing them to the main workstation (recommended method):
Back up the individual projects. To do this, open the Services application and select Data Backup -> Create -> Entire folders -> Projects.
You can back up several projects in a single operation.
Before you start, specify the backup folder on the network or on the local hard disk: Services application -> Configuration -> Backup path ->Browse for Folder.

The next step is to import the saved projects to the main workstation.To do this, open theServices application -> Data Backup -> Import -> Projects Before you import the individual projects, you can create new Allplan projects at the main computer. As an alternative, you can also create a new project during the import.

2.b: backing up projects of the individual workstations and importing them to the main workstation (special approach):
This approach should only be used with good reason for exceptional cases as it requires in-depth knowledge of Windows.
With this method, Windows Explorer is used to import the projects to the main workstation.
If some project names exist twice, you need to rename these projects before you back them up.

You can then rename the existing 'project.dat' file in the Prj folder of the main workstation.
Next, select the Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.
The system creates a new project administration file (project.dat), which should list all projects with names.

Now the main workstation contains the latest version of all the projects of the office.

3rd - merging project defaults
Open ProjectPilot at the individual workstations and copy the elements you want to transfer (symbols, smart symbols, lists, schedules, and so on) to the external path. Of course, you can set the external path to a common network folder that can be accessed by all workstations.
Next, open ProjectPilot at the main workstation and copy the contents of the external path to the office standard.

4th - data backup

  • Back up the projects, office standard and user settings at the main workstation:
    You can also copy the ..\prj (projects), ..\std (office standard) and ..\usr (user folder) paths to a backup folder (Nemsic, for example) on the hard disk.
  • In addition, you need to back up the ..\usr\local folder at every stand-alone computer.
  • Export the user interface setting of each user to a file: Allplan -> Tools - > Customize .... -> Export...


5th - uninstalling
Remove Allplan from all workstations.

6th - reinstalling
Before you install the same version again, create and share a folder (Nemdata, for example) on the future data server. Create a subfolder - Allplan - in this folder.

The next step is to reinstall the same version on all the workstations.

Specify the following installation paths:
Program folder:
local (C:\Programs\Nemetschek\Allplan, for example)
Central file storage folder:
Browse -> Network...
Find the sharedNemdata folder and select the Allplan folder.

After this, start installing.

7th - testing the start and restoring the backup
After the installation (check whether Allplan starts), copy the ..\prj and ..\std folders you backed up from the main workstation to the new ...\Nemdata\Allplan server folder.

Next, use Windows Explorer to copy the contents of the former user folder (…\usr\local) of the stand-alone workstation to the new user folder of the computer you just installed.

8th - updating the project administration file
Go to the project.datfile in the ...\Nemdata\Allplan\Prjfolder and rename itproject.alt.After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.

9th - summary
Now all the workstations access a common network drive with the same project pool and office standard.
With this type of installation, only one user can access a project at any one time. If several users are to work on a project at the same time, you need to install Workgroup Manager.

Загрузка PDF  FAQ_EN_Switching_from_single_installation_to_network...
Версия:  Allplan 2021  | Последнее изменение: 06.10.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Information:

This document provides additional information on installing Allplan 2021.

Data backup/archiving:

We strongly recommend that you perform a complete data backup and archive this data before you upgrade to Allplan 2021!


Installation Instructions:


Detailed installation instructions can be found in the following places:

- If you have downloaded and unpacked Allplan 2021, you will find the file install.chm in the folder C:\Users\Public\Documents\Allplan 2021\HelpFiles\English


Please read these before installing Allplan 2021.

System requirements Allplan 2021

https://connect.allplan.com/de/faqid/20200930085615.html

Licenses when upgrading to Allplan 2021

https://connect.allplan.com/en/faqid/20200821110044.html


Extract from the installation instructions (see above)

If you want to switch from Allplan 2018/2019/2020 to Allplan 2021, you have three basic installation options.

1. New installation

Allplan 2021 is installed in a new folder. Any existing installations of Allplan (2020 or older) are not affected. No data and settings are transferred to the new installation.

The following options are available for transferring data later:

Uninstall Allplan 2021 and then upgrade Allplan 2018/2019/2020.
Integrating the data by hand (administrator knowledge required).

2. New installation with data copy from version

Allplan 2021 is installed in a new folder. Any existing installations of Allplan (2020 or older) are not affected. The office standard (\std), projects (\prj) and user data (\usr) can be automatically copied from an existing version 2018/2019/2020 to the new installation folder.
In this way, you can create a duplicate dataset if necessary: all projects, standards and resources can be used in both Allplan 2021 and 2018/2019/2020. This allows you to test the transition to the new version in real life, while the existing Allplan installation remains fully functional.
Note, however, that this method of working should avoid parallel processing of data in both installations, as the subsequent merging is time-consuming.

2a. Continuation of new installation with data copy from version

This option is available if a new installation with data copy has already been performed on another computer accessing the same data server and therefore the data has already been transferred.

3. Upgrade with data transfer from version 2018/2019/2020

Allplan 2021 is installed in an existing folder. The existing installation of Allplan 2018/2019/2020 is converted to Allplan 2021 and all important settings are transferred (see also Limitations for Data Transfer). Allplan 2018/2019/2020 is then no longer available.
Any existing installations older than Allplan 2018 are not affected.


Network Installations:

For network installations (shared 'central file storage folder'), only one main release version can be used - all workstations must be brought to Allplan 2021. Before starting the installation, make sure that all workstations have upgrade authorization. A mixed installation of different main versions is not technically approved. Complications that may arise are not covered by the maintenance contracts.

During the upgrade, no workstation may be running any version 2020, 2019 or 2018.

In case of an installation with Workgroupmanager all workstations must be checked in during the upgrade.




Data Conversion:

Data from older Allplan versions must be converted to version 2021. This happens automatically for projects opened in Allplan 2021. For instructions on how to convert all projects at once, click here:

https://connect.allplan.com/de/faqid/20090408124904.html

Загрузка PDF  FAQ_EN_Hotletter_2021.pdf
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 24.10.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

The licensing service crashes regularly or does not start at all. Afterwards, no license is available. How can I solve this problem?



Answer:

Problems with the licensing service may have various causes.

If this problem occurs with specific clients only, you can find the cause on these clients. If this problem occurs with all clients, you can find the cause on the server.
Check the following points:


1. Virus scanner
The Codemeter Runtime Server service is running both on the client and on the server.

If the service is blocked on the client, this is often caused by the virus scanner.
However, this may also happen on the server.

If communication with the Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So, you need to exclude the "Codemeter" folder from virus scans. You can find this folder in the virus scanner in the following path: C:\Program files (X86)\Codemeteror C:\Programs (x86)\Codemeter. You can find the “Codemeter” folder in the following path:C:\Program files\Codemeteror C:\Programs\Codemeter.

Restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



2. Update the CodeMeter program
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.html

Start the "CodeMeterRuntime.exe" file.
To do this, right-click this file and select
"Run as administrator".
Confirm all messages displayed and the defaults by clicking “Next”.
CodeMeter Control Center will be installed afterwards.



3. Other causes
Open the “C:\Windows\System32\drivers\” or “C:\Windows\SysNative\drivers\” folder and check whether this folder includes a file called "Multikey.sys". You must delete this file.
Before you delete this file, open Windows Device Manager (Control Panel) and check whether a driver called "Virtual USB Multikey X64" is installed.
If this driver is installed, uninstall it
before you delete the "Multikey.sys” file.
If this driver is not installed, delete the "Multikey.sys” file straightaway.

Note:
Sometimes, the system uses the "Multikey.sys” file in the c:\windows\system32\drivers\ folder to emulate a dongle.
This file is blacklisted by Wibu, as it interferes with the Wibu license system.

Sometimes, you can even find the "Virtual USB Multikey x64" device driver when you open Windows Device Manager.
If this driver exists, the "Multikey.sys” file will also exist.



4. Windows
The license server is based on .Net Framework. Allplan uses .NET 4.6. (Allplan 2019 and later will use .NET 4.7). Like any other Windows service, the Codemeter Windows service running on the license server depends on Windows components such as WMI. WMI depends on RPC, and RPC depends on COM distribution.

There may be a bug in Net. Framework of the operating system.
Fixing Net. Framework may solve the problem.

Check Windows Event Viewer and system information for .Net or WMI errors.
.Net may not be installed correctly,
Control Panel -> Administrative Tools -> Event Viewer -> Windows Logs
Check the application, installation and system.
Windows Event Viewer -> Windows Logs -> Application may include an application error in Allplan licensing. This error may be connected with .Net Framework.
Event ID = 1026 This ID indicates an error which you may fix by repairing the installation of .Net Framework.

Fixing Net. Framework may solve the problem.
Go to the Microsoft Support website at https://support.microsoft.com/de-de/help/2698555/microsoft-.net-framework-repair-tool-is-available.
There you can find a repair tool for fixing errors in .Net Framework.


Check Windows Event Viewer and system information for .Net or WMI errors.
.Net may not be installed correctly,
Control Panel -> Administrative Tools -> Event Viewer -> Windows Logs
Check the application, installation and system.




Note:
Do you have a second server? Test the license server on this sever. Install the license server on this server and activate the license there. Use the description at
https://connect.allplan.com/en/faqid/20150618134224.html
Has this solved the problems?

Загрузка PDF  FAQ_EN_Licensing_service_is_not_running.pdf
Версия:  Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 13.05.2020
1 user(s) found this FAQ helpful

Question:

The windows for options and the window for IFC import and export are closed immediately when opened. How can this issue be solved?



Answer:


1. HP computer

If you are using an HP (Hewlett-Packard) computer, please take these steps. Otherwise proceed to number 2.

Check whether the security software "HP ProtectTools" is installed on this computer. If yes, then uninstall "HP ProtectTools". This software suite consists of several progams. In most cases, these programs are:

  • HP ProtectTools Device Access Manager
  • Embedded Security for HP
  • Face Recognition for HP ProtectTools
  • File Sanitizer For HP ProtectTools
  • Privacy Manager for HP ProtectTools
  • Theft Recovery
  • Drive Encryption for HP ProtectTools
  • HP ProtectTools Security Manager



It is possible that more or less HP software than the listed is installed. When you uninstall the "HP ProtectTools Security Manager", no other dependent software should be listed during uninstallation.

If there is dependent software listed during uninstallation, please uninstall these programs first. As the last step, "HP ProtectTools Security Manager" should be uninstalled.

An example message, listing dependent software which is still installed:




Important notice: Please restart the computer to complete uninstalling the software.




2. Dell computer

If you are using a Dell computer, please take these steps. Otherwise contact the Allplan support.

Check whether the security software "Dell Data Protection" is installed on this computer. If yes, then uninstall "Dell Data Protection". This software suite consists of several progams. In most cases, these programs are:

  • Dell Data Protection | Security Tools Authentication
  • Dell Data Protection | Security Tools


It is possible that more or less Dell software than the listed is installed. When you uninstall the "Dell Data Protection", no other dependent software should be listed during uninstallation.

If there is dependent software listed during uninstallation, please uninstall these programs first. As the last step, "Dell Data Protection" should be uninstalled.

An example message, listing dependent software which is still installed:




Important notice: Please restart the computer to complete uninstalling the software.




Notes:

HP ProtectTools Security Suite was developed by McAfee in cooperation with HP. It is pre-installed on most HP business notebooks and on some HP desktop computers.

HP ProtectTools are using Full Volume Encryption (FVE) by McAfee Safeboot, which changes the Win32 API behaviour. This causes problems in Allplan.

Also Dell is using similar mechanisms for the Dell Data Protection Suite. They have the same influence on Allplan.

Please note that these programs in either case have negative effects on stability and functionality of Allplan, even if you might not notice it (example: working options and IFC windows in different Allplan version).


Загрузка PDF  FAQ_EN_Options_window_IFC_window_closed_immediately_...
Версия:  Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011 / Allplan 2009  | Последнее изменение: 22.01.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I remove NemSLock completely from a computer?



Answer:

Do the following:

  1. Uninstall Softlock 2006 by clicking Start -> Control Panel -> Programs and Features.

  2. Select "Nemetschek SoftLock 2006" and then click "Uninstall/Change". Select "Remove" -> Next -> Yes.
  3. Extract the "NSLFixer2006.zip" file attached and copy it to any folder on your computer. If your email provider or firewall software has blocked this file, you can also download it from our webdrive. Use this link:

    https://webdrive.allplan.com/index.php/s/4LrjrymoxESzC6p

    The tool "NSLFixer2006.exe" is under Allgemein/Nemslock

    (click on the right hand side next to file size on the three dots and chose 'herunterladen')

  4. Start NSLFixer2006.exe by double-clicking it.
    Important note:
    If you are running Windows Vista or a newer operating system, click the program with the right mouse button and select "Run as administrator". Confirm the following message.
  5. Create the key by clicking "Generate/Enter a key" (1).

  6. Select the line to the right of "Generate/Enter a key" (2), "1F02E74917D3F6E7348C1F02E74917D35E2599A254864A233C549A25ADD2EDFD", for example, and press "Ctrl+C". Paste this key into an email and send it to "support.de@allplan.com".
  7. We will send you another key. Please copy this key to the second line (3). If you need to restart the program, paste the key you created into the first line (see step 3, do not click "Generate/Enter a key" again!). Then click "Validate twin key" (4). After you have done this, you should see the following message: "System cleaned. Reinstall NemSLock".
  8. Update your current Allplan version. Use the temporary license file ("psd" can be found in its file name). You can also find your current temporary licenses at www.connect.allplan.com. Go to "Profile -> License administration".
    Students should use the Allplan Setup program which they can download from Allplan Campus (http://www.allplan-campus.com -> log on -> select "Software" at the top -> download Allplan). Use the trial license provided by Setup.



After this, request a new license by sending a new registration request (Services application -> Utilities -> License -> License Manager). Select the license entry for your seat and click "Request license".
If you work with a license server, reconnect the client with the server.

Загрузка PDF  FAQ_EN_Removing_NemSLock_completely.pdf Загрузка NSLFixer2006_EN.zip
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Последнее изменение: 25.11.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

During installation I get an error message saying that SetupSchedTaks.exe does not work anymore.

When I try to start Allplan or the Services application, the following message appears:
The program cannot start; api-ms-win-crt-runtime-l1-1-0.dll is missing.



Answer:

This problem is caused by missing DLl files, which are required by Allplan. These DLL files usually come with the operating system. You will only see these messages if the operating system is not up-to-date. These messages are not caused by Allplan.
Instead, this problem is caused by the KB2999226 or KB2918614 (Universal CRT) Windows updates, which contain parts of Visual C++ Redistributable for Visual Studio 2015. Sometimes you cannot install these updates or they are defective.

If you have not yet installed these updates, install them now. In addition, install all available updates.

If you have already installed these two updates, try to install them again.
If the operating system is configured to automatically install Windows updates, some clients report errors during installation of the KB2918614 or KB29992226 package. These errors are caused by Windows, which blocks installation of files of the Visual Redistributable 2015 package. In this case, you must uninstall or delete the updates. After this, try to install the updates again.


If you cannot install the updates, do the following:
1. Deactivate automatic updates
2. Start -> Control Panel -> Windows Update -> change the settings -> never check for updates
3. Restart the computer
4. Download and install missing updates
5. Activate automatic Windows updates again


If you still cannot install the updates, run Windows diagnostics to check your system for update problems.

You can also install the updates manually. Use the following links:

KB2918614:
https://www.microsoft.com/de-DE/download/details.aspx?id=43759

KB2999226:
https://www.microsoft.com/de-de/download/details.aspx?id=49093


Try this if you still cannot install the updates:
https://www.smartftp.com/support/kb/the-program-cant-start-because-api-ms-win-crt-runtime-l1-1-0dll-is-missing-f2702.html



Note:

Regarding this error message, we cannot fix anything on the part of Allplan. These DLL files, which are required by Allplan, are an integral part of the Windows operating system.

Загрузка PDF  FAQ_EN_Missing_api-ms-win-crt-runtime-l1-1-0dll_prev...
Версия:  Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Последнее изменение: 19.03.2018
1 user(s) found this FAQ helpful

Question:

What effects do Windows 8.1 updates have on Allplan versions?


Answer:

Allplan versions 2014-0-2 and later are running on Windows 8.1.
To make sure that Allplan runs smoothly after you have updated to Windows 8.1, you need to do the following:

1st step: backing up and restoring Allplan user settings

Prior to installing the Windows update, select
Services application -> Data Backup -> Create -> Entire folders -> Private settings -> Full
to back up your own Allplan user settings.

If you find out that some settings are missing after you have updated to Windows 8.1, you can select
Services application -> Data Backup -> Import -> Entire folders -> Private settings -> Full
to restore these settings.

In addition, you are strongly advised to back up and archive all the data before you update the operating system!



2nd step: restoring Allplan licensing

Depending on the licensing system you use, there are different issues to bear in mind.

NemSLock
After the Windows update you need to fix Nemetschek Softlock License Manager as described in the following document:
https://connect.allplan.com/de/faqid/20131024085525.html


Hardlock
Uninstall the hardlock driver (Sentinel runtime driver) during the update to Windows 8.1 as described below:
https://connect.allplan.com/de/faqid/20131028131634.html

Install the latest hardlock driver after the Windows update. You can find the driver and the instructions using the following link:
https://connect.allplan.com/de/faqid/20131028125253.html

Загрузка PDF  FAQ_EN_Windows_81_update.pdf
1 - 10 (12)
https://connect.allplan.com/ uses cookies  -  More information

Accept