Search Result

41 - 50 (123)
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 29.12.2020
 

Task:

You want to transfer a project with all its settings to a partner office for further editing.

Note:

The following description works only if both partners use the same version of Allplan (Allplan 2018-1 or later).

1. Backing up the project:

Before you back up the project, make sure that “office” or “project” is selected for the path settings of the project.
To do this, open ProjectPilot and select the project: right mouse button -> Properties-> Settings. Here, you can select the path settings.
For exchanging projects with partner offices, we recommend that you switch all project settings to “project”.
This ensures that all pen definitions and line definitions, user-defined fonts, patterns and hatching styles, bar and mesh cross-section catalogs, and layer definitions will be copied to the project and backed up together with the project.

Note:
After the backup, switch the path settings back to “office”. But do not change the paths that already had the “project” setting.

Start Allplan and select the “File” menu -> “New Project, Open Project...”.
Right-click the project that you want to back up and select "Create project backup".
(Allplan 2018: Select “Compress and export project”: )
Select the folder where you want to save the project.

2. Importing the project:

To add a compressed project to the "New Project, Open Project" dialog box

Start Allplan and select the “File” menu -> “New Project, Open Project...”.

  • Drag a compressed project (*.zip) from the desktop or from File Explorer into the "New Project, Open Project" dialog box.
  • Specify the folder and enter a name for the project; then, click OK.
  • Allplan unzips the project, adding it to the project list.


Download PDF  FAQ_EN_Transferring_projects_with_all_settings_to_pa...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 16.12.2020
 

Question:

What can I do if Allplan does not start?


Answer:


Work through the following steps:

Step 1 - run as administrator
Start Allplan with the ‘Run as administrator’ option.
To do this, right-click the Allplan icon and click ‘Run as administrator’.
If Allplan does not start, go to step 2.

Step 2 - cleanup
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanup -> OK
If Allplan does not start, go to step 3.

Step 3 - cleanstd
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanstd: reset CAD defaults -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the settings:
Services application -> Service -> Hotline Tools -> laststd: restore the last settings -> OK -> OK -> Yes -> OK
Go to step 4.

Step 4 - cleanreg
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanreg: reset CAD registry settings -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the registry settings:
Services application -> Service -> Hotline Tools -> lastreg:restore most recent CAD registry settings -> OK -> OK -> Yes -> OK
Go to step 5.

Step 5 (Allplan 2016 and later)
Restart the Wibu service:
Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.

If Allplan does not start, go to step 6.

Step 6 (Allplan 2016 and later)
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.htmlor on the Nemetschek FTP server ftp://nemhotline:ha37jvg8f@ftp.nemetschek.deat download/General/Wibu/CodemeterRuntime.exe

Start the ‘CodeMeterRuntime.exe’ file.
To do this, right-click this file and select
‘Run as administrator’.
Confirm all messages displayed and the defaults by clicking ‘Next’.
CodeMeter Control Center will be installed afterwards.
If Allplan does not start, go to step 7.

Step 7 - contact Technical Support
Send the following information by email to support.de@allplan.com:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
  5. Allplan 2016 and later -> a screenshot of the Wibu Control Center. To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.


We will contact you.

Download PDF  FAQ_EN_Allplan_does_not_start.pdf
Version:  Allplan 2020  | Last modified: 27.11.2019
 

Question:

Allplan crashes when you open the Wall dialog - what can you do?



Answer:

Since Allplan version 2020, you can also use OpenGL in Allplan if you use an onboard graphics card. Provided this card supports the OpenGL version listed in the system requirements:

System requirements Allplan 2020

In connection with outdated grafic card drivers and current Windows updates, the described crashes may occur in individual cases.

In this case, please update the drivers of your graphics card(s) first by downloading the appropriate driver from the manufacturer's homepage and then installing it:

AMD grafics driver
Intel grafics driver
NVIDIA grafics driver

Important: please do not use the Update Driver button in the Device Manager.

If the problem is not solved after the driver update, please contact your Allplan support.

Download PDF  FAQ_EN_Allplan_crash_when_opening_the_wall_dialog.pd...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Last modified: 29.12.2020
 

Question:

I want to run Allplan on a terminal server. Can I use any other terminal server than Citrix?



Answer:

Microsoft terminal server or Horizon is not approved for Allplan.
In addition, running Allplan on a terminal server requires an Allplan license server for managing the Allplan licenses.
If you have only used stand-alone licenses until now, you must purchase the additional ‘license server’ option. Should you have any questions, please contact your sales partner.


VM Ware (Horizon) or RDP is not approved for Allplan. This means that you do not get any support for this constellation.
You may not have any problems with the current Allplan version. However, future developments will not take RDP or VM Ware into account. Consequently, this functionality may be limited or not available at all in future Allplan versions.

Citrix is the only terminal server that is approved for Allplan.
You can find information at
https://www.allplan.com/de/system/systemvoraussetzungen/


Download PDF  FAQ_EN_Allplan_on_a_terminal_server.pdf
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 25.06.2019
 

Question:

What can I do if Allplan starts as a viewer only and I have to install a new hardlock driver?



Answer:

Install the latest hardlock driver.

How to install:

Use the following link to download the driver:

https://webdrive.allplan.com/s/4LrjrymoxESzC6p

The driver for Windows 7 and 8.1 is in the following folder.
/Download/Allgemein/Dongle/

If you are using Windows 10 then use the driver under the folder:
/Download/Allgemein/Dongle/Win10

Extract and save the 'haspdinst.exe' file to any folder, for example, c:\drivers. Then open the command prompt:
Right-click Start (Windows button) -> Command Prompt (Admin)
Switch to the folder where you saved the file. To do this, type in "cd c:\drivers".

To remove the old drivers, enter the following command:
haspdinst -fremove
Next, install the new driver:
haspdinst -install


Note:

If you use a parallel hardlock, read the following instructions:
https://connect.allplan.com/en/faqid/20121011092418.html

Download PDF  FAQ_EN_Installing_a_new_hardlock_driver.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Last modified: 30.12.2020
 

Question:

What can I do if Allplan no longer starts after I have upgraded and the following messages appear?
Allplan
Stop

...

After this, Quality Reporter displays an error report.



Answer:

Exit Allplan on all workstations and do the following:
Open the Services application and make a note of the path to the 'central file storage folder', which is displayed in the Services application window.
In addition, check whether the workgroup manager line is followed by 'Yes' or 'No'.

Open the central file storage folder in Windows Explorer.

If the workgroup manager line is followed by
'Yes', open the NET subfolder.
'No', open the PRJ subfolder.

Find the 'project.dat' or 'project.Dat.xm' file in the NET or PRJ folder and rename it 'project-old.dat'.

After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> OK -> Restore project management file -> OK
The program creates a new, correct project management file and you can start Allplan again.



Note:

If you come across error messages while doing this, please email the following information to support@allplan.com:

  1. Describe exactly what you did before the error or crash occurred.
  2. The error message itself (as a screenshot).
  3. The log file (trace).
    https://connect.allplan.com/en/faqid/0001a27a.html
  4. A Hotinfo support request with question 01.
    https://connect.allplan.com/en/faqid/20130823123806.html
Download PDF  FAQ_EN_Allplan_does_not_start_after_upgrade_Stop_mes...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 30.09.2020
 

Question:

I installed Allplan with Workgroup Manager on a new computer for the first time. When I start Allplan, I get the following message: The user profile "DOMAIN\user name" was not found. Temporarily, the profile of local will be used.
Therefore, I cannot access any project. What can I do?



Answer:

You have logged in to the computer with a new Windows user who does not yet exist in Workgroup Manager administration of Allplan.
You need to add this new user to Workgroup Manager. To do this, log in as the administrator to the computer or use a different computer where a user has administrator privileges for Workgroup Manager.

Services application -> Workgroup Manager -> Administrate users -> right-click -> Create user

For the "user name", you can enter any Allplan user name, which can be up to 8 characters long.
For the "Windows user name", you must enter the name the user uses for login.
Important: If the user uses a domain for login, you must add it to the "Windows user name", for example, DOMAIN\user.


There is one Allplan administrator and any number of normal Allplan users.
A Windows user with any login name becomes an Allplan administrator if you go to "User group" and
select "Administrator"on the dropdown menu. Using this approach, you can also assign administration privileges to existing users.


You must enter the email address and the password only if the user is notpart of the workgroup but needs access to online projects (Workgroup Online).


Important: Click "Apply" and then "OK" to close the dialog box and the user overview respectively.



Note:

After you have created the user as an Allplan user, do not forget to assign the relevant projects to this user. Otherwise, this user is not allowed to edit the projects.
To find out how to
make several projects available to users: https://connect.allplan.com/en/faqid/0001cbd2.html

Download PDF  FAQ_EN_The_user_profile_was_not_found_Temporarily_th...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 27.10.2020
 

Question:

I can neither check in nor check out the computer.
When I try to check in the computer, the following error message appears: “The registry entries are not correct!” How can I correct this error?


Answer:

There is a hidden file on the server. This file causes the problem, which is probably related to user rights or user account control.

You have to change the settings directly on the server, that is so say, you have to use the folder options to show all hidden folders and files.

1. Open the central file storage folder on the server. There is a subordinate folder called
NET. This folder contains the computer_name.out file. Here, computer_name is the name of the computer that is checked out.
Delete this file.

2. Open the shared folder (for example, C:\Nemdata\Allplan) on the computer that is checked out.
Allplan 2015 and earlier: Delete the Net.ChkOutfolder.
Allplan 2016 and later: Delete the NETfolder.

Now the computer is checked in again. Consequently, you can move projects to this computer
or check it out once more.


Note:

If the computer or the projects are still red, you have to fix the projects.

To fix the projects:
Services application -> Workgroup Manager -> Administer projects and computers

Do the following:

Ctrl + right-click computer
-> can be checked in
Ctrl + right-click project-> can be unlocked

Repeat this step to unlock every project on the computer.
When you have finished, close the dialog box and open it again to update it.
Now everything should be correct.

Download PDF  FAQ_EN_Workgroup_Manager_Problems_when_checking_in_o...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.10.2020
 

Question:

I have installed a Windows update. Now the license is no longer available.
When I start Allplan, I can see the following error message: "This license is no longer available" or "CmActLicense runtime system is not installed!" How can I restore the license?




Answer:

CodeMeter Control Center always saves the license to a container with the number Allplan GmbH 128-XXXXXXX on your computer.

Start CodeMeter Control Center:
Open the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.
Check the Licenses area to see whether there is the following container: Allplan GmbH 128-XXXXXXX.
The container must have a blue-green symbol and not a red symbol


Work through the following steps:

Step 1 Restart CodeMeterService
The local Windows service, which is used by licensing, must be running.

Restart this service:
CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.

Now check whether the Allplan GmbH 128-XXXXXXX container is displayed.

If this has solved your problem, all you need to do is exclude Codemeter from virus scans as described in the following document: https://connect.allplan.com/en/faqid/20151209133620.html

If the container is still not visible, go to step 2.


Step 2 Contact Support
Send the following information for analysis by e-mail to support.de@allplan.com:
If the container is not displayed, or is still displayed with a red symbol, please send us

1. a screenshot of the Codemeter Control Center. License tab.
Either found in the Windows Start menu via CodeMeter -> CodeMeter Control Center. Or enter Codemeter in the search bar on the start page.

2. the computer name from which the screenshot was taken. (can be found on the start page of the Allmenu->second line "Computer Name")

3. the license/workstation number, or the product key used

Download PDF  FAQ_EN_No_valid_license_available.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.10.2020
 

Question:

Does Allplan create backup files (*.bak)?
How can I use these files?



Answer:

Allplan creates backup files when you do the following:

  1. Copy, Move Elements between Documents …
    Allplan creates a backup file of the destination drawing file or layout.
  2. Deleting drawing files and layoutsin the "Open on a project-specific basis" dialog box
    If you have selected "Create backup copies of drawing files", Allplan creates a backup file of the drawing file or layout.
  3. Importing data to drawing files
    If you have selected "Create backup copies of drawing files", Allplan creates a backup file of the drawing file.


Note on points 2 and 3:

To select the "Create backup copies of drawing files" option, click
Tools -> Options -> Desktop environment -> Save/load area (until V2009 Global Options -> Miscellaneous -> Autosave, Backup)->Create backup copies of drawing files.


Restoring:

If need be, you can restore the original drawing file or layout.
Make a note of the drawing file number or layout number and determine the corresponding project folder as follows:
Services application -> Service -> Hotline Tools -> wopro

Open this folder in Windows Explorer.

Rename the corresponding drawing file "tb000001.ndw" "tb000001.ndw.old" or the corresponding layout "pb000001.000" "pb000001.000.old.", for example.
Delete the bak extension from the corresponding bak file.

Example 1:

You have inadvertently copied the wrong elements to drawing file 4711.
1st step: exit the project in Allplan.
2nd step: delete file tb004711.ndw or rename it tb004711.ndw.old.
3rd step: find file tb004711.ndw.bak and rename it tb004711.ndw.

Example 2:

You have inadvertently copied the wrong elements to layout 815.
1st step: exit the project in Allplan.
2nd step: delete file pb000815.000 or rename it pb000815.000.old.
3rd step: find file pb000815.000.bak and rename it pb000815.000.



Note:

These backup files can considerably increase the volume of data to be backed up. So it is a good idea to delete the .bak files you no longer require before you start backing up data. To delete the .bak files, you can select the Services application and click Utilities -> Delete temporary files.

You can also find this information in the help for Allplan. Please refer to the topic "Using bak files".

Download PDF  FAQ_EN_Using_bak_files.pdf