Search Result

1 - 6 (6)
  • 1
Version:  Allplan 2021  | Last modified: 24.08.2021
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

What does this error message mean and how can I fix it? How can I change the path and switch from server to local?

Response:

For the use of Allplan Share, a defined path for the "LocaldataPath" is used for the temporary storage of the project data to be edited. In Allplan 2021, a default setting was made so that the LocaldataPath should always be in the Windows user folder. However, for customers who place their users on the server, this causes the problem that 80 characters are exceeded.
Since hotfix 2021-0-3 there is a possibility to change this path to local by creating a registry entry.


Note:

The procedure described below is done at your own risk.
Questions about this should be clarified before the practical implementation.
Always make a copy of a file before making any changes to it.
Before changing registry entries, create a backup of the registry key to be modified by exporting the key in the registry editor under File->export.
We recommend that you have this work done by an experienced technician.


After you have installed at least version 2021-0-3 of Allplan, proceed as follows:

Be sure to exit Allplan before making the change to prevent data loss and errors.

  1. On a local C: or D: drive of the computer used for Allplan, create a new folder with the name "Local data" and the subfolder "Allplan" (e.g. C:\Local data\Allplan) .
  2. In Windows, as an administrator, start the Windows Registry Editor (Start-> Run-> Regedit) .
  3. In the registry, in the left column, open the key: HKEY_LOCAL_MACHINE\SOFTWARE\Nemetschek\Allplan\2021.0\InstallRoot.
  4. In the right window, right-click and select New -> String Value. Create a string value with the names LocalDataDrive and a string value with the name LocalDataPath.
  5. Now activate the edit mode for the "LocalDataDrive" key in the right column of the registry editor by double-clicking the left mouse button and enter here only the drive you have chosen for the local file storage (e.g. C: ) and confirm the change with "OK". Thus the change is taken over in the registration editor.
  6. Then activate the edit mode for the "LocalDataPath" key in the right column of the registry editor by double-clicking the left mouse button and enter the additional path defined for the local file storage (e.g. \LocalDataPath ) and confirm the change with "OK". The change will be applied to the registry editor. The result should look as follows:


  7. Close the registration editor. Allplan now uses the newly defined path for the Allplan Share cache.

Restart the Allmenu and you will see the local path displayed there.


Download PDF  FAQ_EN_Error_message_LocalDataPath_exceeds_maximum_l...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 17.06.2021 11:15
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I change the cache path for Allplan Share?

Note:

You do this at your own risk.
We strongly recommend that you clarify all issues in advance.
Always copy a file before you change it.
Before you change registry entries, back up the registry key that you want to modify. To do this, export the key by selecting File - Export in the Registry Editor.

Answer:

Allplan Share temporarily saves the project data in the path of the local file storage, which you defined when you installed Allplan.
You can see the path of the local file storage folder in the Services application.
If this folder is centrally on a server for all Allplan workstations:
To avoid replication conflicts that might occur when several users work on the same project data, you must change the path settings for each user so that this folder is locally on the user’s computer running Allplan.

Before you start, close Allplan, making sure that you do not lose any data.

  1. Go to a local drive (C or D) of the computer running Allplan and create the new "Local data” folder with the "Allplan” subfolder (for example, C:\Local data\Allplan).
  2. Start the Windows Registry Editor as the administrator (start - run - regedit).
  3. Go to the left column of Registry Editor and open the following key: HKEY_LOCAL_MACHINE\SOFTWARE\Nemetschek\Allplan\2018.0\InstallRoot. If Allplan 2019 or a newer Allplan version is installed, “2019.0“ or the newer version replaces “2018.0” in the path.
  4. Go to the right column of Registry Editor and double-click theLocalDataDrivekey. Specify the drive that you selected for local file storage (for example, C:). Then click OK to confirm the change. This applies the change.
  5. Then, go to the right column of Registry Editor again and double-click theLocalDataPathkey. Specify the path that you defined for local file storage (for example,\Local Data\Allplan). Then click OK to confirm the change. This applies the change. The result should look like this:
  6. Close the Registry Editor. Allplan now uses the new path for the cache of Allplan Share.
  7. Start Allplan and select the Allplan Share project to load the necessary project data into the new cache.



Download PDF  FAQ_EN_Adjusting_the_local_file_storage_folder_for_A...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 17.06.2021 11:20
Not voted yet. Be the first to vote this FAQ as helpful!

Questions:

Why can’t I see anything in a project or why are elements missing from drawing files?
Why are layers not visible?
Why is it not possible to select a privilege set in layer selection?



Answer:

Probably, you have not yet been assigned any privilege sets or the layers are frozen in the privilege set in question. First, check whether you can select another privilege set.


1. Selecting another privilege set

To do this, select the project in question and open the layer settings(Format -> Select, Set Layers). Go to the “Privilege set in list box” area at the top on the right and check whether you can select another privilege set (for example, ALLPLAN).
By default, all layers have full access rights in the predefined ALLPLAN privilege set.

If there is no privilege set with full access rights, you should assign the privilege sets correctly.
This can only be done by a user with administrator privilegesor, in the case of a project-specific layer structure, by the project owner.

Thus, log on as a user with administrator privileges and do the following:


2. Assigning a privilege set

Select the project with the frozen layers.

Open the layer settings(Format -> Select, Set Layers). Switch to the "Privilege Set" tab and click Define, modify privilege set.

Select the relevant user and assign the privilege set using the arrows.

Click OKto confirm.


3. Adjusting layers’ access rights in the privilege set

Finally, check the access rights of the layers in the privilege set assigned.
Go to the "Privilege set in list box" area at the top on the right and select the relevant privilege set (for example, ALLPLAN).

Check the area on the left to see whether there are frozen layers (gray or white). To change this, select these layers or simply select all layers using CTRL+A. Then click the Full access right (modifiable)icon in the “Change rights” area.
Click OKto confirm.

The next time you open this project, you can select this privilege set in the layer settings. You can then see all layers and set them to modifiable.

Do the same with print sets.


Alternative:

Since version 2006, the administrator has been able to select Show all users all print sets and privilege setsin the “Administrator options” group on the “Privilege Set” tab (“Design group” in version 2006). Thus, you do not need to assign new users to privilege sets. This option applies to all projects.

However, as soon as a user has been given a privilege set or print set, this option no longer applies to this user.



Note:

As a project can have its own layer structure, it is essential that you check the privilege set in the correct project.
To find out whether a project has its own layer structure, click
File -> New Project, Open Project-> right-click the relevant project -> Properties. Check whether the path settings for Layerstructuresare set to Officeor Project.

Download PDF  FAQ_EN_Enabling_privilege_set_for_user.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 17.06.2021 11:08
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Why does ProjectPilot open with the following error message:
"Unable to create ProjectPilot control. Is the registry correct?"



Answer:

The reason for this is usually an "external path" that no longer exists. When you start ProjectPilot,
the program tries to access the "external path", which is stored in the Windows Registry.
If this path no longer exists, you will see the above error message.

To correct this error, please do the following:

  • Services application
  • Service menu
  • Windows Explorer - CAD program folder
  • The path to the "User folder" is displayed in the window of the Services application. Open it in Windows Explorer.
  • Find the "extern.cfg"file in this user folder and delete this file.


Now try to start ProjectPilotagain. If the problem still occurs, please do the following:

Start the services application -> Service -> Windows Explorer -> CAD program folder.
Open the "PRG" folder.
Find the following file: "NemProjectPilot10.exe"
Right-click this file -> select "Run as administrator" on the shortcut menu.
ProjectPilot should now start.

Try to start ProjectPilotstraight from Allplan. If the problem is still not solved, please do the following:

  • Services application
  • Service menu
  • Windows Explorer - CAD program folder
  • The Allplan program folder opens.
  • Rename the "PRG" subfolder "PRG_OLD".
  • Start installing the program from the current Allplan DVD.
  • Select "Update installation".
  • Select "Current license file".
  • Set the setup type to "Minimum".


After installation try to start ProjectPilotagain.

Download PDF  FAQ_EN_Error_message_when_ProjectPilot_starts_Unable...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Last modified: 17.06.2021 11:24
1 user(s) found this FAQ helpful

Question:

ProjectPilot does not open, displaying the following error message:
“Unable to create ProjectPilot control. Is the registry correct?” What can I do?



Answer:

Step 1
Start the Services application -> Service -> Windows Explorer -> CAD program folder.
Open the "PRG" folder.
Find the following file: "NemProjectPilot10.exe"
Right-click this file -> select "Run as administrator" on the shortcut menu.
Try to start ProjectPilot from Allplan.
If ProjectPilot does still not start, go to step 2.


Step 2
Check whether updating the software of the virus scanner solves the problem.
If it doesn't, configure the real-time scanner of the virus scanner so that
it no longer scans the program folder and data folder of Allplan.
Start the Services application: Make a note of the following paths displayed in the Services application window:
Program folder
General program data
Central file storage folder
Define these folders as exemptions in your virus scanner.
If ProjectPilot does still not start, go to step 3.



Step 3
This problem is often caused by an "external path" that no longer exists. When you start ProjectPilot,
the program tries to access the "external path", which is stored in the Windows Registry.
If this path no longer exists, you will see the above error message.

To correct this error, do the following:

  • Start the Services application -> Service -> Windows Explorer -> My own CAD documents (USR).
  • Find the "extern.cfg"file in the user folder and delete this file.


If ProjectPilot does still not start, go to step 4.



Step 4 (Windows 10 or later)
Open the PRG folder of Allplan in Windows Explorer (for example, C:\Programs\Allplan\Allplan 2018\prg).
Start the Services application. The folder you selected for the Allplan program during installation is displayed directly in the Services application window.
Right-click the "NemProjectPilot10.exe" file in the Allplan program folder. A shortcut menu opens. Click “Properties”.
Open the “Compatibility” tab and select the “Disable fullscreen optimizations” option. After having selected this check box, click “Apply” at bottom right.




If several users with different user profiles use Allplan on this computer, click the “Change settings for all users” button first. Then, disable fullscreen optimizations as described above.




If ProjectPilot does still not start, go to step 5.



Step 5
Fix Allplan.
To find out how, go to
https://connect.allplan.com/en/faqid/20120917082945.html
After installation, try to start ProjectPilot.
If ProjectPilot does still not start, go to step 6.



Step 6
If ProjectPilot does still not start, the most likely cause of this problem is security software such as the virus scanner.
Remove, that is, uninstall the local virus scanner with all its services from the Allplan computer having these problems.
After this, ProjectPilot will start.
To reinstall the security software or virus scanner with its appropriate settings,
contact the support service of the software provider.

Download PDF  FAQ_EN_ProjectPilot_does_not_start.pdf
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 14.07.2021
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

What are the reasons why I cannot modify the format properties (pen thickness, color, ...) of elements in a DWG/DXF file I have just imported?



Answer:

There are four reasons why these elements cannot be modified.

1st -the elements are smart symbols:

  • To retain the smart symbols but still be able to modify the elements, select Modify -> Bonus Tools -> Smart Symbols -> Modify Smart Symbol(until V2006: Modify -> Bonus Tools -> Smart Symbols -> Modify Display Parameters) and click the relevant element. Now you can modify it (using Modify Format Properties, for example). For more detailed information on how to modify smart symbols, please contact us.
  • If you do not want to retain the smart symbol, you can also resolve it: Modify -> Bonus Tools -> Smart Symbols -> Unlink Smart Symbol, select the smart symbol(s) you want to resolve and click the right mouse button to confirm.
  • To resolve the smart symbols during import, select the file to be imported, click the"Options..."button,open the "Advanced Settings" tab (until Allplan 2008 "Advanced Transfer Settings")and select the"Smart symbol"check box in the"Explode elements" area. To confirm the dialog box, click OKand open the file.


2nd - theelements are composite elements:

  • To explode a composite element, select Modify -> Advanced Draft -> Explode Composite Element. Select the composite element(s).
  • To resolve the composite elements during import, select the file to be imported, click the "Options..." button, open the"Advanced Settings" tab" (until Allplan 2008: "Advanced Transfer Settings") andselect the "Composite elements"check box in the"Explode compounds" area. To confirm the dialog box, click OKand open the file.


3rd - the elements are on frozen layers:

  • To modify these elements, you first have to set the corresponding layers to modifiable. Open the layer selection by clickingFormat -> Select, Set Layers.On theSelect Layer/Visibilitytab, set all the layers to modifiable.


4th - the elements have the "from layer" format property:

  • To find this out, click an element with the right mouse button and selectFormat Propertieson the shortcut menu: pen thickness, line type or line color is not available for elements with the "from layer" format property.
  • To modify the format properties of the layer, select Format -> Select, Set Layers and open the'Format Definition' tab. Check that the''Match from layer based on line style, pen, line, color assigned (fixed setting)"optionis selected in the"Layers' format properties" area. Next, select the layer on which the element resides and change its format properties.
  • To remove this property, clickEdit -> Modify Format Properties, select the"Change 'from layer' for pen, line and color" option(pen thickness, line type and line color must not be selected) and select the elements.
  • To resolve the "from layer" property during import, select the file to be imported, click the "Options..." button, open the"Advanced Settings" tab" (until Allplan 2008: "Advanced Transfer Settings") andselect the "From layer"check box in the"Explode compounds" area. To confirm the dialog box, click OKand open the file.




Note:

If you have any further questions regarding data exchange, this topic is described in detail in the online Help. All you need to do is press the F1 key. Open the Index tab and selectInterfaces.

Download PDF  FAQ_EN_Elements_cannot_be_modified_after_import.pdf ...
1 - 6 (6)
  • 1