Search Result

1 - 10 (13)
Version:  Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 15.11.2017
 

Question:

How can I update cross-section catalogs or install country-specific cross-section catalogs in Allplan 2011 and later?



Answer:

To install and save cross-section catalogs in Allplan 2011 and later, select Tools -> Defaults -> Cross-Section Catalogs. A dialog box opens. You can find a folder symbol and a disk symbol at bottom left.

To install cross-section catalogs, use the folder symbol. Another dialog opens, where you can select the cross-section catalog file you want to install. Select the file to be installed and click "Open" to confirm. This installs the corresponding cross-section catalog, which you can now use in Allplan.
To install country-specific cross-section catalogs, select the "Ing" folder, which was created when you installed Allplan. You can find it in the Allplan installation path (e.g., c:\Nemetschek\Allplan 201x\New\Ing - more information on the Allplan installation path is provided below in the "Notes" section).
This folder includes the country-specify cross-section catalog files.

To save a custom cross-section catalog, use the disk symbol. Another dialog opens, where you can select any folder to save the cross-section catalogs currently used in Allplan.



Note:

To update cross-section catalogs, you may need administrator privileges. If necessary, log on as an administrator before you start the update.

To use the cross-section catalogs for a specific project only, set the path settings for the cross-section catalogs of this project to project before you install the cross-section catalogs. In Allplan, open the "File" menu and select "Open Project..." Click the corresponding project with the right mouse button. Select "Properties". A dialog box opens. In the "Path settings" area, set the "Bar and mesh cross-section catalogs" to "Project".

To determine the path where Allplan is installed, use the Services application and select Service -> Hotline Tools-> showcfg. The Services application window shows the path of the Allplan installation folder.

The following abbreviations are used for the country-specific cross-section catalogs in the file names (axyzqusr.txt):
aut Austria
bel Belgium
bra Brazil
bul Bulgaria
deu Germany
eng England
fra France
hol Holland
hrv Croatia
ita Italy
kor Korea
pol Poland
rum Romania
rus Russia
slk Slovakia
svn Slovenia
swi Switzerland
tch Czech Republic
ung Hungary
usa USA

Download PDF  FAQ_EN_Updating_cross-section_catalogs_(Allplan_2011...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 30.09.2020
 

Question:

How can I check out a computer and continue to work as a normal CAD user with my usual settings and permissions?



Answer:

Install the "Microsoft Loopback Adapter" driver.
This driver is necessary so that network services are running on the computer all the time.
Go to Allplan Connect for a detailed description: https://connect.allplan.com/en/faqid/000162ae.html


Sign in as the Allplan administrator to the computer.


Step 1: add the computer to workgroup manager
You must add the computer to the workgroup so that you can store data (data server) on this computer. Do the following:

Create data folders:
Create a folder - for example, “Nemdata” - on the computer and share it (full control).
Create the “Allplan” subfolder in this folder. Create two subfolders - “usr” and “prj” - in the Allplan folder.
In this example: “...\Nemdata\Allplan\prj” and “...\Nemdata\Allplan\usr”

To share a folder for the Allplan file storage

  1. Start File Explorer on the computer that you want to use for file storage and switch to the folder that you want to share (in this example, the “Nemdata” folder).
  2. Right-click the folder that you want to share and select Give access to -> Specific peopleon the shortcut menu.
  3. Select Everyoneand click Share.


Add computer:

  1. Start the Services application as the workgroup administrator.
  2. Click and select Manage computers and projects.
  3. Click the Add any computer to Allplan workgroupicon and select the computer that you want to add.
  4. Select the “Allplan” subfolder under the share and click “OK” to confirm. This computer is now listed under workgroup server.


Note:If you have problems adding the computer to workgroup manager, read the following instructions:
https://connect.allplan.com/en/faqid/20200317162849.html



Step 2: define project owner
A user can only move a project if the user is the owner of this project.
The ownership of a project can only be changed by an Allplan administrator (or the owner of the project).
Allplan -> File -> ProjectPilot ->
Go to the “Projects” node, right-click the required project and click Propertieson the shortcut menu.
Define the owner.


Step 3: move projects
Sign in as the user who wants to check out the computer.
Select the Services application -> Workgroup Manager -> Manage computers and projects.
Click the main server and select the project that you want to move.
Drag the projects one after the other to the computer to be checked out.

Important note: You can take projects with you in several ways.

1. You move the project to the computer.
Move project: Drag the project to the destination computer, or open the shortcut menu of the project and click “Cut”. After this, open the shortcut menu of the destination computer and click “Paste”.
After you have checked in the computer, move the project back to the server so that it is available to all and included in backups again.

2. You copy projects. Click a project, select and hold the Ctrl key and drag the project to the destination computer. Or: Open the shortcut menu of the project and click “Copy”. After this, open the shortcut menu of the destination computer and click “Paste”.

You can continue in two ways: Lock the original project on the server to protect it from changes. Consequently, nobody in the office can work on this project, but it is still on the server. When you check in the computer again, you unlock the project on the server, delete the project and copy your copy back to the server if you have changed the project.
Alternatively, both projects remain active. Consequently, both the project copied and the original on the server can be worked on. In this case, however, you must adjust the data manually when you are back in the office by copying the changed drawing files of the projects by using ProjectPilot.




Step 4: check out the computer
Select the Services application -> Workgroup Manager -> Manage computers and projects.
Click your computer and then click Check outin the lower-right area.
Confirm the message that tells you that there are still user folders on the computer to be checked out.
Enter a comment and click OK. Users in the office see this comment when they try to access a project that is on the computer that is checked out.
Specify the parts of the office standard you want to copy to the computer and click OK to confirm.
The first time you check out the computer, you must copy the office standard once so that the entire STD folder is on this computer. This is no longer necessary when you check out the computer afterward because the contents of the STD folder do not change very often.


Conclusion:

You can now remove the computer from the network and work on your projects when you are out of the office. To make sure that the projects are not changed in the office in the meantime, the projects that are on the computer checked out are locked for the CAD users on the network. These users see the comment you entered when you checked out the computer.



Notes:


Download PDF  FAQ_EN_Workgroup_Manager_checking_out_computer_and_w...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 30.09.2020
 

Question:

I have used the "Check out" tool to check out the computer from the network and remove the network connection.
Why is Workgroup Manager no longer working?



Answer:

Windows disables network functionality as soon as you remove the network connection (unplug the network cable).
Running Allplan, however, requires specific network protocols (even if the computer is checked out).



Solution:

To make sure that the operating system's network functionality is not interrupted, you can install a virtual network interface card.
Microsoft provides a driver for this (loopback adapter).

How to install:

Windows 8/10:
Right-click the Windows Start button -> select "Run".
Type in "hdwwiz" in the search field. Right-click the program found -> select "Run as admin".
Click Next -> select the required hardware manually in a list and install it -> click "Next".
Select "Network adapter" in the list -> click "Next".
Select "Microsoft" in the list on the left -> "Microsoft loopback adapter for KM TEST" is presented for selection on the right -> click "Next" -> click "Next".

Windows 7:
Click the Windows Start button -> type in "hdwwiz" in the search field. Right-click the program found -> select "Run as administrator".
Click Next -> select the required hardware manually in a list and install it -> click "Next".
Select "Network adapter" in the list -> click "Next".
Select "Microsoft" in the list on the left -> "Microsoft loopback adapter" is presented for selection on the right -> click "Next" -> click "Next".

Windows Vista:
Start the "Hardware Wizard" by selecting
Start -> Control Panel -> Hardware and clicking Continue -> Next.
Select "Install the hardware that I manually select from a list (advanced)" in the box and choose "Network adapter" in the list that follows.
This selects and installs the "Microsoft loopback adapter".

Download PDF  FAQ_EN_Installing_loopback_adapter_for_a_stand-alone...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 12.11.2020
 

Question:

How can I change the cache path for Allplan Share?

Note:

You do this at your own risk.
We strongly recommend that you clarify all issues in advance.
Always copy a file before you change it.
Before you change registry entries, back up the registry key that you want to modify. To do this, export the key by selecting File - Export in the Registry Editor.

Answer:

Allplan Share temporarily saves the project data in the path of the local file storage, which you defined when you installed Allplan.
You can see the path of the local file storage folder in the Services application.
If this folder is centrally on a server for all Allplan workstations:
To avoid replication conflicts that might occur when several users work on the same project data, you must change the path settings for each user so that this folder is locally on the user’s computer running Allplan.

Before you start, close Allplan, making sure that you do not lose any data.

  1. Go to a local drive (C or D) of the computer running Allplan and create the new "Local data” folder with the "Allplan” subfolder (for example, C:\Local data\Allplan).
  2. Start the Windows Registry Editor as the administrator (start - run - regedit).
  3. Go to the left column of Registry Editor and open the following key: HKEY_LOCAL_MACHINE\SOFTWARE\Nemetschek\Allplan\2018.0\InstallRoot. If Allplan 2019 or a newer Allplan version is installed, “2019.0“ or the newer version replaces “2018.0” in the path.
  4. Go to the right column of Registry Editor and double-click theLocalDataDrivekey. Specify the drive that you selected for local file storage (for example, C:). Then click OK to confirm the change. This applies the change.
  5. Then, go to the right column of Registry Editor again and double-click theLocalDataPathkey. Specify the path that you defined for local file storage (for example,\Local Data\Allplan). Then click OK to confirm the change. This applies the change. The result should look like this:
  6. Close the Registry Editor. Allplan now uses the new path for the cache of Allplan Share.
  7. Start Allplan and select the Allplan Share project to load the necessary project data into the new cache.



Download PDF  FAQ_EN_Adjusting_the_local_file_storage_folder_for_A...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 30.09.2020
 

Question:

How can I make several projects available to users when Workgroup Manager is installed?



Answer:

You can make several projects available to a user or define a user as the project owner of several projects.

Do the following:

First, log in as the Allplan administrator.
If necessary, set up an Allplan user for the new Windows user: Services application -> Workgroup Manager -> Configuration -> Add a user
(Allplan 2014 and later:Services application -> Workgroup Manager ->Administer users)

Start Allplan and then ProjectPilot by clicking
File -> ProjectPilot

Open the Projects folder in the area on the left.
You can see all the projects in the Contents of "Projects" area on the right.

a. Making several projects available to users:
In the area on the right, select the projects to which you want to add users or from which you want to remove users (CTRL or SHIFT key or use a selection rectangle).

Click one of the selected projects with the mouse button. On the shortcut menu, click
Add / remove authorized users...
The Add / Remove Authorized Usersdialog box opens.

Select the users you want to add to or remove from the selected projects.
Note:
The user list displayed only helps you select users. It does not list all the authorized users currently assigned to projects.

Click Addor Remove.
This adds or removes the selected users to or from the selected projects. Whether users you have already added to a project are added again is irrelevant. The same applies if you remove users you have never added to a project.

b. Defining a project owner for several projects
In the area on the right, select the projects for which you want to define the owner (CTRL or SHIFT key).

Click one of the selected projects with the mouse button. On the shortcut menu, click
Change project owner...
The Define Owner dialog box opens.

Select the user you want to define as the owner of the selected projects.
Note: The user list displayed helps you select users. You can define only one user as the owner.

Click OK.

c. Defining a project owner for a project or making a project available to several users(also applies to earlier versions):
In ProjectPilot in the area on the right, click the relevant project with the right mouse button. On the shortcut menu, click Properties.
The Properties for <project name>dialog box opens. Switch to the Security tab and define the owner and the authorized users.



Note:

You can add or remove project users or define the project owner only if the projects in question are in the current Allplan format.

Download PDF  FAQ_EN_Making_several_projects_available_to_users.pd...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 25.11.2020
 

Questions:

Why can’t I see anything in a project or why are elements missing from drawing files?
Why are layers not visible?
Why is it not possible to select a privilege set in layer selection?



Answer:

Probably, you have not yet been assigned any privilege sets or the layers are frozen in the privilege set in question. First, check whether you can select another privilege set.


1. Selecting another privilege set

To do this, select the project in question and open the layer settings(Format -> Select, Set Layers). Go to the “Privilege set in list box” area at the top on the right and check whether you can select another privilege set (for example, ALLPLAN).
By default, all layers have full access rights in the predefined ALLPLAN privilege set.

If there is no privilege set with full access rights, you should assign the privilege sets correctly.
This can only be done by a user with administrator privilegesor, in the case of a project-specific layer structure, by the project owner.

Thus, log on as a user with administrator privileges and do the following:


2. Assigning a privilege set

Select the project with the frozen layers.

Open the layer settings(Format -> Select, Set Layers). Switch to the "Privilege Set" tab and click Define, modify privilege set.

Select the relevant user and assign the privilege set using the arrows.

Click OKto confirm.


3. Adjusting layers’ access rights in the privilege set

Finally, check the access rights of the layers in the privilege set assigned.
Go to the "Privilege set in list box" area at the top on the right and select the relevant privilege set (for example, ALLPLAN).

Check the area on the left to see whether there are frozen layers (gray or white). To change this, select these layers or simply select all layers using CTRL+A. Then click the Full access right (modifiable)icon in the “Change rights” area.
Click OKto confirm.

The next time you open this project, you can select this privilege set in the layer settings. You can then see all layers and set them to modifiable.

Do the same with print sets.


Alternative:

Since version 2006, the administrator has been able to select Show all users all print sets and privilege setsin the “Administrator options” group on the “Privilege Set” tab (“Design group” in version 2006). Thus, you do not need to assign new users to privilege sets. This option applies to all projects.

However, as soon as a user has been given a privilege set or print set, this option no longer applies to this user.



Note:

As a project can have its own layer structure, it is essential that you check the privilege set in the correct project.
To find out whether a project has its own layer structure, click
File -> New Project, Open Project-> right-click the relevant project -> Properties. Check whether the path settings for Layerstructuresare set to Officeor Project.

Download PDF  FAQ_EN_Enabling_privilege_set_for_user.pdf
Version:  Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Last modified: 22.02.2018
 

Question:

How can I copy bar reinforcement including views and sections created with the tools in the "Associative Views" module if, for example, I want to use slab reinforcement for another floor?
I want to place the copied reinforcement and the views in new, separate drawing files and then adjust the reinforcement, keeping the layout of the copied sections. Only the changes in the copied reinforcement should automatically be added to the sections.


Answer:

First, open ProjectPilot (File -> ProjectPilot) and copy the drawing files with the reinforcement and the drawing file with the associative views and sections to new drawing files. ProjectPilot asks you whether you want to copy the linked drawing files as well. Click No.

If there are views or sections containing only data you do not want to move (for example, only model data), select Create -> Engineering Views, Details -> Associative Views -> Add to Viewand add the data you want to move (for example, reinforcement) to these views or sections. You can remove the data later.


The copied drawing files still reference the original drawing files. The next step is to delete those references.

To do this, open the drawing files you just copied. Select Change -> Engineering Views, Details -> Associative Views -> Manage Reference Drawing Filesand remove the references to the source drawing files.



When you have removed all links to drawing files you do not want to move, select the new drawing files with the views and the reinforcement.


Select all data by pressing <CTRL>+A and move the data as you need.
You can move the data in the X, Y and Z directions in plan or define any spatial displacement in isometric view.

You can then add the associated model data to the views and adjust the reinforcement.

Note:

Once deleted, you cannot restore any references to drawing files. Therefore, make sure you delete the right references. Allplan deletes empty views or sections automatically.

Download PDF  FAQ_EN_Copying_reinforcement_with_associative_views_...
Version:  Allplan 2021  | Last modified: 14.12.2020 14:33
 

The original FAQ contains pictures. Use the PDF link to get the complete presentation.

Question:

What does this error message mean and how can I fix it? How can I change the
path and switch from server to local?

Response:

For the use of Allplan Share, a defined path for the "LocaldataPath" is used
for the temporary storage of the project data to be edited. In Allplan 2021, a
default setting was made so that the LocaldataPath should always be in the
Windows user folder. However, for customers who place their users on the
server, this causes the problem that 80 characters are exceeded.
Since hotfix 2021-0-3 there is a possibility to change this path to local by
creating a registry entry.


Note:

The procedure described below is done at your own risk.
Questions about this should be clarified before the practical implementation.
Always make a copy of a file before making any changes to it.
Before changing registry entries, create a backup of the registry key to be
modified by exporting the key in the registry editor under File->export.
We recommend that you have this work done by an experienced technician.


After you have installed at least version 2021-0-3 of Allplan, proceed as
follows:

Be sure to exit Allplan before making the change to prevent data loss and
errors.

On a local C: or D: drive of the computer used for Allplan, create a new folder
with the name "Local data" and the subfolder "Allplan" (e.g. C:\Local
data\Allplan) .
In Windows, as an administrator, start the Windows Registry Editor (Start->
Run-> Regedit) .
In the registry, in the left column, open the key:
HKEY_LOCAL_MACHINE\SOFTWARE\Nemetschek\Allplan\2021.0\InstallRoot.
In the right window, right-click and select New -> String Value. Create a
string value with the names LocalDataDrive and a string value with the name
LocalDataPath.
Now activate the edit mode for the "LocalDataDrive" key in the right column of
the registry editor by double-clicking the left mouse button and enter here
only the drive you have chosen for the local file storage (e.g. C: ) and
confirm the change with "OK". Thus the change is taken over in the registration
editor.
Then activate the edit mode for the "LocalDataPath" key in the right column of
the registry editor by double-clicking the left mouse button and enter the
additional path defined for the local file storage (e.g. \LocalDataPath ) and
confirm the change with "OK". The change will be applied to the registry
editor. The result should look as follows:



Close the registration editor. Allplan now uses the newly defined path for the
Allplan Share cache.
Restart the Allmenu and you will see the local path displayed there.

Download PDF  FAQ_EN_Error_message_LocalDataPath_exceeds_maximum_l...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 30.11.2017 17:22
 

Question:

How to install and run NemSLock Server?



Answer:

Before installing, check whether the package you received includes the following items:

  • Temporary licenses for NemSLock Server, e.g. 1234567a_001_psd.nslsrv
  • Temporary licenses for clients, e.g. 1234567a_001_psd_client.nslock



How to install NemSLock Server

  • Start the Setup program for NemSLock Server. You can find the latest Setup program on our FTP server:

ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de/download/Allplan/Lizenzserver/2014/allplan2014-nemslock-lizenz.zip

  • Select one of the temporary license files for NemSLock Server. These licenses are valid for 30 days. However, each license includes only one seat of each configuration purchased. The full number of seats purchased will be available to you as soon as you have installed the registered licenses (see below). If you purchased a configuration for one seat only, you will, of course, receive only one temporary license.
  • When you opt for the “Custom” setup type, you can choose between the following program features:
    Console
    You can use this program to administer NemSLock Server. You can also install the console on more workstations so that you can administer the server from a number of different locations. However, you can only connect one console to the server at any one time.
    Server
    The actual license server.
    Logviewer
    This tool analyzes the log files of NemSLock Server.

By default, Setup installs all these features.
If you have several temporary licenses for NemSLock Server, use the server console to install the remaining licenses after the installation. The procedure is described in the section "How to install licenses".


How to register licenses

  • Open NemSLock 2006 Server Console by clicking the corresponding icon on the desktop or by selecting Start -> All Programs -> NemSLock 2006 Server -> NemSLock 2006 Server Console.
  • Click "Modules" on the left.
  • Select the seat you want to register. If your license includes configurations for several seats, you must send a separate registration request for each seat. You will then receive a registered license file for each seat. You must install each file.
  • Click the "Registration request (register.txt)" button.
  • Click "Edit".
  • You must fill out all fields marked with an asterisk (*). Make sure you enter your email address correctly, because the registered license file will be sent to this address (and not to the address of the person who sent the registration request!). Click OK to confirm.
  • Click "Create registration request". Windows Explorer opens and shows the register.txt file. If this window is closed, you can find this file in the program folder of NemSLock Server. If you installed the program to the path proposed, the path is:
    C:\Program Files (x86)\Nemetschek\NemSLock Server 2006\Programs\License
  • Now you can use all the options provided by Windows Explorer to copy the registration file to a computer with Internet access on the network. Alternatively, you can also use an USB stick. You can then email this file to us.
  • Send the email with the registration request to register@nemetschek.de



How to install licenses

  • Open NemSLock 2006 Server Console.
  • Click "Stop server" on the left.
  • Click "Modules" on the left.
  • Click "Browse" to navigate to the registered license file.
  • Click "Install license file".
  • After this, you can start the server again by clicking "Start server".



How to set up users (optional)

  • predefined user ALLis created automatically. If there is no other user, each user is given the privileges of the user ALL. By default, this user can use all licenses but cannot check out any licenses. By double-clicking the user, you can change the user&apos;s privileges.
  • predefined user ALLallows all users to use licenses. In order to do this, the users must be able to access the server. You do not need to create individual user profiles until you want to assign specific rights to individual users or limit access to selected users. predefined user ALL. If you want to work only with individual users, you should deactivate the predefined user ALL by revoking the user&apos;s right to use licenses.
  • predefined user ALL has administrator privileges unless another user is created and appointed as the administrator. As soon as you have appointed an administrator, ALL no longer has administrator privileges.
  • You can enter users in the “Users.mcf” file. predefined user ALL has administrator privileges again. In addition, each user can once again administer the license server using the console.
  • The administrator user is not a special user. If there are several administrator users, only one administrator user can start the console for this license server at any one time.
  • If you are setting up users without giving administrator privileges to anyone, the program will ask you whether you want to appoint yourself as the administrator.


You can also specify a domain (user authentication for Windows server). However, this is not mandatory. If you do not specify a domain, the program uses the Windows user name for each user.

The program writes the user accounts and the associated access rights as ASCII text to the users.mcf file.

You can find this file in the \Programs folder of the NemSLock Server installation. You cannot rename, delete or move this file. If the program can no longer connect to this file, you must exit NemSLock Server, restart it and enter all users again from scratch. predefined user ALLis retained.

Note:
Experienced administrators can use the PowerShell script NemGenUsers.ps1. This file is in the \Programs folder of the NemSLock Server installation or you can find it as an FAQ in Allplan Connect:

connect.allplan.com/en/faqid/20120907161911.html



How to install and configure clients

  • Use one of the nslock license files you received to install the clients. Do not use the trial license or the license server license. It is irrelevant which of the client licenses you use, as the actual license will come from the license server later.
  • You do not need to register the clients.
  • When switching from Hardlock to NemSLock (server), you need to update the client using a nslock license file.


After having installed the client, you need to switch to the license server:

  • Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager
  • If the license server window is not visible, select "Configure NemSLock Server" at the bottom. Lock this window. All you need to do is click the drawing pin icon.
  • Enter the computer name or IP address of the license server in the empty box. Then click the "Update” icon to the right.
  • Now the user can select one of the seats provided.
  • After having successfully connected to the license server, clear the check boxes for the trial licenses in the area at the top.
  • Click "Close" to complete the configuration. Now you can start Allplan.



Notes:

  • If a user selects several configurations for a seat and starts Allplan, the license server will provide the required licenses; in other words, starting Allplan once might require two licenses. Consequently, fewer licenses are available to other users.
  • 2014-1 and later: If the latest version of License Manager is installed (file version 1. 0. 26. 153 or later, see License Manager- Options- System), you can also select several licenses. If one of the selected licenses is currently being used by someone else, the program will automatically select the next available license.
  • Clients communicate with the server by TCP/IP via port 10977. So you need to configure the firewall accordingly.
  • The license server and the licenses are downward compatible; they can be used in conjunction with older Allplan versions.
Download PDF  FAQ_EN_Installing_and_configuring_NemSLock_Server.pd...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 17.12.2015
 

Question:

How can I move NemSLock Server to a new server?



Answer:

Reinstalling NemSLock Server

  • Select one of the temporary license files for NemSLock server (for example, 1234567a_001_psd.nslsrv). These licenses are valid for 30 days. However, each license includes only one seat of each configuration purchased. The full number of seats purchased will be available to you as soon as you have installed the registered licenses (see below). If you purchased a configuration for one seat only, you will, of course, receive only one temporary license.
  • When you opt for the “Custom” setup type, you can choose between the following program features:
    Console
    You can use this program to administer NemSLock Server. The console can be installed on several workstations. This way, you can administer the server from a number of different locations. However, you can only connect one console to the server at any one time.
    Server
    The actual license server.
    Logviewer
    This tool analyzes the log files of NemSLock Server.
    User List Generator
    You can use this tool to create the users for NemSLock Server from a text file or based on a server.
    By default, Setup installs all these features.
  • If your license includes configurations for several seats, you need to install the additional temporary license files for NemSLock server after the installation (see below).


Transferring the user administration from the old server (if users are available)

  • You can find the user administration in the program folder of the license server. Copy the "users.mcf" file to the program folder of the new license server.
  • Stop the license server service on the new server before you copy the file. To do this, start the "stopService.bat" program, which is also in the program folder of the license server.
  • After copying, start the license server service again. To do this, use the "startService.bat" program.


Returning the registered licenses

  • Open NemSLock 2006 Server Console on the old server by clicking the icon on the desktop or Start -> (All) Programs -> NemSLock 2006 Server -> NemSLock 2006 Server Console.
  • Click "Stop server".
  • Click "Modules".
  • Click "Transfer license permanently".
  • Confirm the following dialog boxes. Click “Browse”.Windows Explorer starts and opens the folder with the hcws-format file. Now you can use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer with Internet access and so on.Send this file by email to register@nemetschek.de.
  • We will send you an email, confirming that we have received the licenses.
  • You always have to return all licenses.
  • After you have done this, they are only valid for two more days.


Registering the license(s) on the new server

  • Open NemSLock 2006 Server Console on the new license server.
  • Click "Modules" on the left.
  • Select the seat you want to register. If your license contains configurations for several seats, read the notes further down.
  • Click "Registration request (register.txt)".
  • Click "Edit".
  • Fill out all fields marked with an asterisk (*). Make sure you enter your email address correctly, because the registered license file will be sent to this address (and not to the address of the person who sent the registration request!). Click OK to confirm.
  • Click "Create registration request".Windows Explorer starts and opens the folder with the "register.txt" file. Now you can use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer with Internet access and so on.Send the registration request by email to register@nemetschek.de.


If your license includes configurations for several seats, you must send a separate registration request for each seat. You will then receive a registered license file for each seat. You must install each file.

How to install licenses

  • Open NemSLock 2006 Server Console.
  • Click "Stop server" on the left.
  • Click "Modules" on the left.
  • Click ”Browse” to navigate to the registered license file.
  • Click "Install license file".
  • After this, you can start the server again by clicking "Start server".


Configuring the clients

  • Now you need to change each client to the new license server.
  • Click Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager.
  • If the license server window is hidden, click "Configure NemSLock Server"at the bottom. It is a good idea to lock this window. All you need to do is click the drawing pin icon.
  • Enter the computer name or IP address of the license server in the empty box. Then click the "Update” icon to the right.
  • Now the user can select one of the seats provided. Click "Close" to complete the configuration. Now you can start Allplan.
  • After having successfully connected to the license server, clear the check boxes for the trial licenses in the area at the top.


Notes:

  • If a user selects several configurations for a seat and starts Allplan, the license server will provide the required licenses; in other words, starting Allplan once might require two licenses. Consequently, fewer licenses are available to other users.
  • 2014-1 and later: If the latest version of License Manager is installed (file version 1. 0. 26. 153 or later, see License Manager- Options- System), you can also select several licenses. If one of the selected licenses is currently being used by someone else, the program will automatically select the next available license.
  • Clients communicate with the server by TCP/IP via port 10977. So you need to configure the firewall accordingly.
  • The license server and the licenses are downward compatible; they can be used in conjunction with older Allplan versions.
Download PDF  FAQ_EN_Moving_NemSLock_Server_to_a_new_server.pdf ...
1 - 10 (13)
https://connect.allplan.com/ uses cookies  -  More information

Accept