Question:

After crashing, Allplan does not start anymore. When you open license selection in the license settings, you can see the following message: "Cannot find a license for running Allplan." How to solve this problem?



Answer:

Restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



The crash causes this problem. The fact that the license is not available is a consequential error.

Note:

If Allplan crashes often,
send the following information by email to your Allplan Support:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a log file, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
Download PDF  FAQ_EN_Allplan_does_not_start_after_crashing_-_canno...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 20.11.2020
 

Question:

During installation of license server the message appears 'installation failed'. What could be the reason for it?



Answer:

Check the following points:

  • The license server must be installed in a 64 bit windows system. License server is not working on 32 bit system.
  • Make sure the license server setup is saved local on the machine and is not executed over network
  • Stop the real time check of your virus scanner or stop the virus scanner complete during installation. Optionally stop the firewall as well - attention in most cases you have to reboot the server in order to take over the settings.
  • Run the *.exe file over context menu -> run as administrator.
  • If the license server installation still fails. The reason could be NET framework. License server uses NET framework 4.6 and in newer version 4.7. If there are components missing the setup will automatically try to install them. This happens in the background. It will be connected to webpage of Microsoft http://go.microsoft.com/fwlink/?LinkId=397708 and the missing files will be downloaded and installed. If a proxy server is blocking this page the download cannot happen and the license server installation fails. In these cases you will have to configure the proxy server settings to allow the Microsoft URL. Microsoft URL has to be trustworthy. Start installation of license server again.



Addition for license server 2017 on older sever like 2008 R2 server:

If the license server installation still fails and the setup stays at 50%, then the reason is usually .NET framework.
Try to install the .NET version in advance from Microsoft Download.


Installation of. NET framework 4.6 requires at least Windows Server 2008 R2 with SP 1.
For information, also see the following link: https://www.microsoft.com/de-de/download/details.aspx?id=49982


If the installation of the new version keeps failing, try to install a slightly older license server.
It will works the same way with ALLPLAN 2017 but still is operating with .NET 4.5.2.
Use the following link:
ftp://nemhotline: ha37jvg8f @ftp.nemetschek.de/download/Allgemein/Archiv/WiBu/Lizenzserver
Download the License server until 2017-0.

Note:

After successfully installation of license server you will have to connect via internet again in order to activate the license. If using proxy allow the access of the following URLs as well.

https://lc.codemeter.com/59885/gateways/getLicenses.php

https://lc.codemeter.com/59885/gateways/getTicketInformation.php

Download PDF  FAQ_EN_License_server_installation_failed.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 12.11.2020
 

Question:

Why is Allplan running so slow?


Answer:

Check the following points:

1. Current version
Make sure you work with the current Allplan version.

  • Do the following or ask your system administrator to do this:
    Open Allplan and click the ‘?’ icon in the upper right-hand corner. Click ‘Update Allplan’.
    Select 'Find now'. If Allplan finds updates or hotfixes, download the installation packages.
  • Deactivate the virus scanner while your are installing updates or hotfixes. This might require administrator privileges. Contact your system administrator if you have problems.
  • Right-click the Allplan icon on the desktop. A shortcut menu opens.
    Select ‘Run as administrator’ and click ‘Yes’ to confirm the following message.
    As a result, Windows security settings do not block the installation.



2. System requirements:
Check the hardware and software required for your Allplan computer.

2.a)Download and run the system test.
Check the notes.
https://www.allplan.com/de/system/systemvoraussetzungen/

2.b)Check the Allplan system requirements:
https://www.allplan.com/de/system/systemvoraussetzungen/

2.c)You can find information about graphics cards at
https://connect.allplan.com/de/support/grafikkarten.html

2.d)You can find server operating systems you can use for the central file storage of Allplan at
https://connect.allplan.com/en/faqid/20140924094923.html


3. Hotline tools:
Start the Services application, open the ‘Service’ menu and select ‘Hotline Tools’. To save your settings, select the following tools.

- savestd: Saves user defaults.
- savereg: Saves CAD registry settings.

Start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:

- cleanup: Initializes the display.
- cleanstd: Resets CAD defaults.
- cleanreg: Resets CAD registry settings.

Check whether this has solved the problems.
If this is not so, restore the settings you just saved. To do this, start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:
- reststd: Restores saved user defaults.
- restreg: Restores CAD registry settings.


4. Color scheme selected in Allplan:
Start Allplan, open the ‘View’ menu, point to ‘Toolbars’ and select ‘Customize User Interface’. Open the ‘Customize’ tab and set ‘Color scheme and icon design’ to ‘Windows’.


5. Check the availability of all projects that are not online (if you use Workgroup Manager):
Start Allplan, open the ‘File’ menu and select ‘New Project, Open Project’. Deactivate ‘Check availability of all offline projects’.


6. Virus scanner
Check whether an anti-virus program is running in the background of the computer or server.
If so, reduce protection to "programs only".

Scanning "all files" can take a long time, considerably slowing down your computer when you switch between projects or exit the program.
You can exclude the Allplan installation folders from real-time scanning.When you start the Services application, you can see a list of the folders to be excluded.
You can find more information at
https://connect.allplan.com/en/faqid/20091126145752.html
Changes in the settings of the virus scanner only come into effect when you re-start the computer.


7. Aero desktop effects
Deactivate the Aero desktop effects of Windows.
To do this, open the Control Panel, select ‘Ease of Access’ and go to the ‘Make things on the screen easier to see’ area.
Select the ‘Turn off all unnecessary animations (when possible)’ option.


8. Name resolution on the network
If Allplan takes several minutes to start, name resolution on the network may not work.
To check this, do the following:
Right-click the Windows Start Button, select ‘Run’, type in ‘cmd’, click OK, type in ‘Nslookup’ and press ENTER.
Go to the line following the > character, type in the name of the Allplan data server and press ENTER.
The reply starts with the name and address of the server providing name resolution.
You can find the name and address of the Allplan data server in the second group.
If problems occur, contact your network administrator and ask him or her to configure name resolution correctly.


9. Speed of Allplan projects
Check whether some Allplan projects are slower than other Allplan projects.
Start with the empty project and check whether it is slow too.
After this, select any other Allplan project.

If it is only the current project that is slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


10. Network: checking out Allplan using Workgroup Manager
If you use Allplan with Workgroup Manager, you can check whether the problems are caused by the network. To do this, check out the workstation with the project in question and use the project on the local Allplan workstation.
You can find detailed information on checking out an Allplan workstation using Workgroup Manager in the
Services application. Open the ‘Help’ and select ‘Workgroup Manager’.

After you have checked out the workstation, Allplan no longer accesses the central file storage of the server.
If this has solved the problems, they are caused by the network. In this case, the network must be checked in detail.
Contact your network administrator and ask him or her to do this.

If the project is still slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


11. Log files and system information files
If all the points above do not solve the problems, technical support requires more system information about the computer running Allplan.

  • So, we would be grateful if you could send us a support request (Allplan Hotinfo with Allplan logging).
    To create a support request, start the Services application, open the ‘Service’ menu and select ‘Create support request (Hotinfo)’.
    Several dialog boxes open. Select ‘Technical Support Allplan’ and ‘Enquiry with Allplan logging’. Enter all the data required. Finally, click ‘Finish’.
    Another dialog box opens, prompting you to start Allplan. Click the ‘Start Allplan’ button.
    Allplan starts, logging all processes.
    Try to reproduce the problem as exactly as possible.
    Exit Allplan as soon as possible, reducing the data in the log file to a minimum.
    Then click ‘Next’ to generate the support request with the log file.
    You can find more information about Hotinfo at
    https://connect.allplan.com/en/faqid/20140528094911.html
  • To analyze the Windows system environment, we would ask you to send us the logs created by Windows Event Viewer of your computer.
    To start Windows Event Viewer, right-click the Windows Start Button, select ‘Run’ and type in ‘eventvwr.msc’.
    You can also type in ‘Event Viewer’ in the search box of Windows. This displays the link file to the Windows event logs.
    Using Event Viewer, create *.evtx files for the application log and the system log in the ‘Windows Logs’ area and for the ‘Administrative Events’ log in the ‘Custom Views’ area.


Please send us the files.

Download PDF  FAQ_EN_Allplan_is_running_slow.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Last modified: 01.12.2020
 

Note:

You can help the technical support team to process your request by generating a support request with the Hotinfo program and sending it to us.

The generated support request will help to avoid unnecessary questions and delays, as it automatically contains all necessary information pertinent to the problem in question.


Procedure:

The Hotinfo program is installed along with Allplan; you can start it over the following ways:
1. Start -> All Programs -> Nemetschek -> Allplan [version number] -> Hotinfo [version number].
2. Allplan -> ? -> Generate support request (Hotinfo)
3. Allmenu/Services -> Service -> Create Support request (Hotinfo)


Select the team with whom you wish to communicate:
Choose the relevant entry, for example, Technical Support Allplan. The email address of the selected team is entered automatically.

Select the areas on which you have questions:
Please select the question that is pertinent to your support request.
You only need to select question 2 when Allplan support is requesting it from you.

01. General inquiry
02. Inquiry with Allplan logging

Note on question 02:
If you have selected question "02. Inquiry with Allplan logging", you can start Allplan straight form the Hotinfo after the questions.
This will generate and attach a log (trace).
Start Allplan by clicking on the button “Start Allplan”
Carefully reproduce the problem – for example, perform the steps that lead to the failure.
Then click "Next" to generate the support request with the trace.
You can click the "Take screenshot" button at any time while Allplan is running in logging mode. This way, you can quickly and easily save any error messages that may be displayed.

Enter your contact address:
Please enter your name, telephone number and email address
so that the technical support team can contact you.

Please describe the problem:
Describe the problem in detail (for example, include the exact wording of error messages).

Select the files you want to attach to the email:
You can include additional files with important information such as damaged drawing files, NID files or other files.

Note:
These files are only attached to the email when you send the Hotinfo by clicking “Finish” -> Option “Start email program…" or send it to us over File -> Send Message...".
See note further down.

Create the screenshots you want to attach to the email:
You can use the "New screenshot" button to take screenshots of the entire screen and send them as a file attachment to the Hotinfo.

Note:
These files are only attached to the email when you send the Hotinfo by clicking “Finish” -> Option “Start email program…" or send it to us over File -> Send Message...".
See note further down

Finish
Here you have the possibility over the pre-selected option "Start Email program..." to start your email program with the created Hotinfo, the generated files as a file attachment and the correct destination address. You only need to press 'Send'.

Over option "Open Hotinfo file to save it..."you can open the support request, save, and send as an email attachment to support.de (please no spam) @ (please no spam) allplan.com, if no e-mail program is installed locally.
In this case, make sure to attach in addition to the support request all additional files also. Attach the "attached files" and "generated screenshots" independently as attachment to your email.

Download PDF  FAQ_EN_Generating_a_support_request_using_Hotinfo.pd...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 30.09.2020
 

Question:

How can I check out a computer and continue to work as a normal CAD user with my usual settings and permissions?



Answer:

Install the "Microsoft Loopback Adapter" driver.
This driver is necessary so that network services are running on the computer all the time.
Go to Allplan Connect for a detailed description: https://connect.allplan.com/en/faqid/000162ae.html


Sign in as the Allplan administrator to the computer.


Step 1: add the computer to workgroup manager
You must add the computer to the workgroup so that you can store data (data server) on this computer. Do the following:

Create data folders:
Create a folder - for example, “Nemdata” - on the computer and share it (full control).
Create the “Allplan” subfolder in this folder. Create two subfolders - “usr” and “prj” - in the Allplan folder.
In this example: “...\Nemdata\Allplan\prj” and “...\Nemdata\Allplan\usr”

To share a folder for the Allplan file storage

  1. Start File Explorer on the computer that you want to use for file storage and switch to the folder that you want to share (in this example, the “Nemdata” folder).
  2. Right-click the folder that you want to share and select Give access to -> Specific peopleon the shortcut menu.
  3. Select Everyoneand click Share.


Add computer:

  1. Start the Services application as the workgroup administrator.
  2. Click and select Manage computers and projects.
  3. Click the Add any computer to Allplan workgroupicon and select the computer that you want to add.
  4. Select the “Allplan” subfolder under the share and click “OK” to confirm. This computer is now listed under workgroup server.


Note:If you have problems adding the computer to workgroup manager, read the following instructions:
https://connect.allplan.com/en/faqid/20200317162849.html



Step 2: define project owner
A user can only move a project if the user is the owner of this project.
The ownership of a project can only be changed by an Allplan administrator (or the owner of the project).
Allplan -> File -> ProjectPilot ->
Go to the “Projects” node, right-click the required project and click Propertieson the shortcut menu.
Define the owner.


Step 3: move projects
Sign in as the user who wants to check out the computer.
Select the Services application -> Workgroup Manager -> Manage computers and projects.
Click the main server and select the project that you want to move.
Drag the projects one after the other to the computer to be checked out.

Important note: You can take projects with you in several ways.

1. You move the project to the computer.
Move project: Drag the project to the destination computer, or open the shortcut menu of the project and click “Cut”. After this, open the shortcut menu of the destination computer and click “Paste”.
After you have checked in the computer, move the project back to the server so that it is available to all and included in backups again.

2. You copy projects. Click a project, select and hold the Ctrl key and drag the project to the destination computer. Or: Open the shortcut menu of the project and click “Copy”. After this, open the shortcut menu of the destination computer and click “Paste”.

You can continue in two ways: Lock the original project on the server to protect it from changes. Consequently, nobody in the office can work on this project, but it is still on the server. When you check in the computer again, you unlock the project on the server, delete the project and copy your copy back to the server if you have changed the project.
Alternatively, both projects remain active. Consequently, both the project copied and the original on the server can be worked on. In this case, however, you must adjust the data manually when you are back in the office by copying the changed drawing files of the projects by using ProjectPilot.




Step 4: check out the computer
Select the Services application -> Workgroup Manager -> Manage computers and projects.
Click your computer and then click Check outin the lower-right area.
Confirm the message that tells you that there are still user folders on the computer to be checked out.
Enter a comment and click OK. Users in the office see this comment when they try to access a project that is on the computer that is checked out.
Specify the parts of the office standard you want to copy to the computer and click OK to confirm.
The first time you check out the computer, you must copy the office standard once so that the entire STD folder is on this computer. This is no longer necessary when you check out the computer afterward because the contents of the STD folder do not change very often.


Conclusion:

You can now remove the computer from the network and work on your projects when you are out of the office. To make sure that the projects are not changed in the office in the meantime, the projects that are on the computer checked out are locked for the CAD users on the network. These users see the comment you entered when you checked out the computer.



Notes:


Download PDF  FAQ_EN_Workgroup_Manager_checking_out_computer_and_w...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 16.12.2020
 

Question:

What can I do if Allplan does not start?


Answer:


Work through the following steps:

Step 1 - run as administrator
Start Allplan with the ‘Run as administrator’ option.
To do this, right-click the Allplan icon and click ‘Run as administrator’.
If Allplan does not start, go to step 2.

Step 2 - cleanup
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanup -> OK
If Allplan does not start, go to step 3.

Step 3 - cleanstd
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanstd: reset CAD defaults -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the settings:
Services application -> Service -> Hotline Tools -> laststd: restore the last settings -> OK -> OK -> Yes -> OK
Go to step 4.

Step 4 - cleanreg
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanreg: reset CAD registry settings -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the registry settings:
Services application -> Service -> Hotline Tools -> lastreg:restore most recent CAD registry settings -> OK -> OK -> Yes -> OK
Go to step 5.

Step 5 (Allplan 2016 and later)
Restart the Wibu service:
Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.

If Allplan does not start, go to step 6.

Step 6 (Allplan 2016 and later)
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.htmlor on the Nemetschek FTP server ftp://nemhotline:ha37jvg8f@ftp.nemetschek.deat download/General/Wibu/CodemeterRuntime.exe

Start the ‘CodeMeterRuntime.exe’ file.
To do this, right-click this file and select
‘Run as administrator’.
Confirm all messages displayed and the defaults by clicking ‘Next’.
CodeMeter Control Center will be installed afterwards.
If Allplan does not start, go to step 7.

Step 7 - contact Technical Support
Send the following information by email to support.de@allplan.com:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
  5. Allplan 2016 and later -> a screenshot of the Wibu Control Center. To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.


We will contact you.

Download PDF  FAQ_EN_Allplan_does_not_start.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Last modified: 30.12.2020
 

Question:

What can I do if Allplan no longer starts after I have upgraded and the following messages appear?
Allplan
Stop

...

After this, Quality Reporter displays an error report.



Answer:

Exit Allplan on all workstations and do the following:
Open the Services application and make a note of the path to the 'central file storage folder', which is displayed in the Services application window.
In addition, check whether the workgroup manager line is followed by 'Yes' or 'No'.

Open the central file storage folder in Windows Explorer.

If the workgroup manager line is followed by
'Yes', open the NET subfolder.
'No', open the PRJ subfolder.

Find the 'project.dat' or 'project.Dat.xm' file in the NET or PRJ folder and rename it 'project-old.dat'.

After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> OK -> Restore project management file -> OK
The program creates a new, correct project management file and you can start Allplan again.



Note:

If you come across error messages while doing this, please email the following information to support@allplan.com:

  1. Describe exactly what you did before the error or crash occurred.
  2. The error message itself (as a screenshot).
  3. The log file (trace).
    https://connect.allplan.com/en/faqid/0001a27a.html
  4. A Hotinfo support request with question 01.
    https://connect.allplan.com/en/faqid/20130823123806.html
Download PDF  FAQ_EN_Allplan_does_not_start_after_upgrade_Stop_mes...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Last modified: 20.01.2021
 

Question:

You would like to know which colleague has borrowed a license from the license server and for what period of time it was borrowed?


Answer:

Prerequisite:
Please make sure that at least Codemeter version 6.60b is installed on the license server.
To do so, start the CodeMeter Control Center on the server
Either in the Windows Start menu via CodeMeter -> CodeMeter Control Center. Or enter Codemeter in the search bar of the start page and press ENTER. Under Help-> About you can see the installed Codemeter version. If a version lower than 6.60b appears here, install the latest version of the Control Center released by Allplan. Instructions on how to do this can be found at the following link https://connect.allplan.com/de/faqid/20160113131406.html


Application:
The administration of the license server is done via the CodeMeter WebAdmin application on the server itself.
Start the CodeMeter Control Center at the license server on the server
Either in the Windows Start menu via CodeMeter -> CodeMeter Control Center. Or in the search bar of the start page enter Codemeter
and press ENTER, then click WebAdmin in the dialog box at the bottom right.

Or:
Type Localhost:22350 in the address bar of your browser.

In WebAdmin go to Container -> All Containers -> here select your Allplan Cm6 in which your license/s have been stored -> select the desired license by clicking on the Product Code 999 in front of it. -> Now scroll down to the end, to the License Transfer History area.

Here you can see exactly when the license was borrowed, for how long and by which user.


Hints:
If you want to see which users are currently in the network pulling licenses from the license server, you can also see this. To do this, go to License Monitor-> Sessions in WebAdmin.

Borrowed licenses are currently only displayed with the container number under License Monitor-> Sessions, only under License Transfer History the user is also visible.

Since under License Transfer History it is a complete history, all license loans are listed, even those that have already been terminated, i.e. the license has been returned to the license server in the meantime.

Download PDF  FAQ_EN_License_server_-_license_borrowing_tracking_w...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 30.09.2020
 

Question:

You want to include a computer in the Allmenu via Workgroupmanager, but no network environment is displayed and no result appears when you enter the computer name in Search. How can the computer still be included?



Answer:

All computers included in the Workgroupmanager are stored in the data.cfg on the server in the central file storage request.
The Allmenu window shows the exact path of the "central file storage folder".

e.g. \\SERVER\data\Allplan
Go via Windows Explorer to the central file storage folder in the NET folder and open the file data.cfg (e.g. with the editor)

The content of the file looks like this
SERVER \data\Allplan

(So far no computer has been included and therefore there are no further entries in this example)

Here you can enter the new path of the computer to be recorded
Simply enter the computer name, spacebar, shared folder, subfolder as a new line.
Enter only your simple host name here, not the FQDN name (first name only, without periods and other additions)

Please make sure that all entries are flush with each other. Please do not remove the space bars in existing entries and also insert a space bar after the host name when entering, these are important.

So it looks like this

SERVER \data\Allplan
COMPUTERNAME \Nemdata\Allplan

Save the file.

As a result, the computers in the workgroup are displayed in the Allmenu/Services application under Workgroupmanager - > Administer projects and computers and can now be checked out.

Download PDF  FAQ_EN_Workgroupmanager_Adding_the_computer_is_not_p...
Version:  Allplan 2021  | Last modified: 14.12.2020 14:33
 

The original FAQ contains pictures. Use the PDF link to get the complete presentation.

Question:

What does this error message mean and how can I fix it? How can I change the
path and switch from server to local?

Response:

For the use of Allplan Share, a defined path for the "LocaldataPath" is used
for the temporary storage of the project data to be edited. In Allplan 2021, a
default setting was made so that the LocaldataPath should always be in the
Windows user folder. However, for customers who place their users on the
server, this causes the problem that 80 characters are exceeded.
Since hotfix 2021-0-3 there is a possibility to change this path to local by
creating a registry entry.


Note:

The procedure described below is done at your own risk.
Questions about this should be clarified before the practical implementation.
Always make a copy of a file before making any changes to it.
Before changing registry entries, create a backup of the registry key to be
modified by exporting the key in the registry editor under File->export.
We recommend that you have this work done by an experienced technician.


After you have installed at least version 2021-0-3 of Allplan, proceed as
follows:

Be sure to exit Allplan before making the change to prevent data loss and
errors.

On a local C: or D: drive of the computer used for Allplan, create a new folder
with the name "Local data" and the subfolder "Allplan" (e.g. C:\Local
data\Allplan) .
In Windows, as an administrator, start the Windows Registry Editor (Start->
Run-> Regedit) .
In the registry, in the left column, open the key:
HKEY_LOCAL_MACHINE\SOFTWARE\Nemetschek\Allplan\2021.0\InstallRoot.
In the right window, right-click and select New -> String Value. Create a
string value with the names LocalDataDrive and a string value with the name
LocalDataPath.
Now activate the edit mode for the "LocalDataDrive" key in the right column of
the registry editor by double-clicking the left mouse button and enter here
only the drive you have chosen for the local file storage (e.g. C: ) and
confirm the change with "OK". Thus the change is taken over in the registration
editor.
Then activate the edit mode for the "LocalDataPath" key in the right column of
the registry editor by double-clicking the left mouse button and enter the
additional path defined for the local file storage (e.g. \LocalDataPath ) and
confirm the change with "OK". The change will be applied to the registry
editor. The result should look as follows:



Close the registration editor. Allplan now uses the newly defined path for the
Allplan Share cache.
Restart the Allmenu and you will see the local path displayed there.

Download PDF  FAQ_EN_Error_message_LocalDataPath_exceeds_maximum_l...
1 - 10 (14)
https://connect.allplan.com/ uses cookies  -  More information

Accept