Результат поиска

1 - 6 (6)
  • 1
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 30.10.2020
4 user(s) found this FAQ helpful

Question:

  • Why can't I create elements?
  • Why can't I move a drawing?
  • Why are elements not created correctly?
  • Why does the program crash when I import a DXF file from the land registry office?
  • Why is the outline of a circumscribed area not detected correctly?
  • Why can't I calculate shadows?
  • Why are elements not displayed correctly in animation?
  • Why are parts of dimension text missing?
  • Why do the contents of the screen suddenly rotate?
  • Why can't I get a preview when I move or copy elements?
  • Why are areas not calculated correctly?




Finding the reason for these problems:

Check whether an offset is set in the project settings (File -> New Project, Open Project-> select the project and open the shortcut menu -> Properties; Allplan 2009 and earlier: Tools -> Options ->Advanced Draft -> Settings). If there are offset coordinates, clear the check box.

Select Tools -> Measure(->)Coordinates.
Click in the middle of the drawing in plan view.
If there are very large values (for example, x/y/z greater than 5000 m), you have found the reason for these problems.

The system has problems calculating and displaying data with very large coordinates. The more data you have with very large coordinates, the greater this effect.



Solution:

  • Click Tools -> Options... -> Desktop environment -> Generaland select Optimize working with large coordinates(Allplan 2009 and earlier: Tools -> Options -> Global Options -> Miscellaneous tab -> Optimize working with large coordinates). After this you must restart Allplan. Otherwise, this setting has no effect.

This is a user setting you must define separately for each user.

  • Usually, the best solution is to move the data towards the Allplan origin. Use the "Move" tool. When Allplan prompts you to specify the target point ("To point"), select Global point in the dialog line. You can find detailed information in the help for Allplan. Look for the Global pointtopic.



Note:

If the data are still not displayed correctly, do the following:
Exit Allplan -> Services application-> Service -> Hotline Tools-> cleanup -> start Allplan.

Загрузка PDF  FAQ_EN_Large_coordinates.pdf
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 06.12.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Which graphics cards are recommended for Allplan?



Answer:


Follow this link to see a list of the AMD/ATI & NVidia graphics cards manufacturers that are CERTIFIED FOR ALLPLAN.
We have tested the OpenGL functionality and the animation performance of various Allplan modules with specially prepared data with each of the cards available.
https://www.allplan.com/services/cad-software-support/grafikkarten.html

The tested drivers can be found on the homepage of the individual manufacturer. The driver versions that were used in the tests are included in the tables so that you can compare the data. However, we strongly recommend that you always installthe current driver of the manufacturer.

It is a good idea to check your system using the system tool you can find on our homepage:
https://www.allplan.com/services/cad-software-support/downloads.html



Additional information:

Allplan 2011 was revised completely for accelerated graphical representation.
To guarantee full performance support for Allplan 2011 and later, please check that your graphics cards meet the hardware requirements for DirectX 10 & OpenGL 2.0 (chip-based). In addition, you need to install the current drivers. Allplan will automatically switch to the conventional drawing method when it starts and finds old graphics cards that do not meet the requirements stated above.

For more information on graphics card specifications, go to

http://en.wikipedia.org/wiki/Comparison_of_AMD_graphics_processing_units
http://en.wikipedia.org/wiki/Comparison_of_NVIDIA_graphics_processing_units#Quadro)



Note:

We kindly ask you to understand that products of other manufacturers that are not mentioned have not been tested and therefore cannot be recommended.

Загрузка PDF  FAQ_EN_Recommended_graphics_cards_for_Allplan.pdf ...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012  | Последнее изменение: 30.01.2020
1 user(s) found this FAQ helpful

Task:

You have installed Allplan on several local workstations. Now you want to change the installation so that you can access a common network drive.



Note:

Before you switch to a network installation, it is essential that you back up all the data of all the workstations.
We strongly recommend that you take advantage of the expertise of Nemetschek’s technical support staff. We are happy to help you!



Solution:

The following description shows how to change several workstations where Allplan is installed locally and the project data is also stored locally on each computer to workstations with a common network drive without Workgroup Manager.

1st - getting ready
Choose one of the workstations where you will install all the projects and the office standard (hereinafter referred to as the main workstation).
First, move all the projects to the main workstation.

1.a: copying resources into projects
To make sure that the projects in your office have a uniform appearance, change the path settings for the projects' resources to 'Project'.
Make the following setting for each project:
Allplan -> File menu -> ProjectPilot - Admin -> select the individual projects one after the other -> right mouse button -> Properties -> Settings tab
Set the path settings for 'Pen and line definitions', 'Fonts', 'Patterns, hatching styles, area styles', 'Bar and mesh cross-section catalogs', 'Layer structures, line styles, drawing types' and 'Attributes proposed' from 'Office' to 'Project', if necessary.
The corresponding elements are copied from the office standard directly to the project. This ensures that the project settings stay the same even when you copy the project to the new server with the new office standard.

1.b: same folder name as project name
Open the 'General' tab and select the 'Same folder name as project name' setting if you want to proceed as described in 2b.

1.c: pen color ("Color stands for pen")
The pen color for the "Color stands for pen" setting is a user-specific setting that is not saved in the project but in the user folder (...\Usr).

2.a: backing up projects of the individual workstations and importing them to the main workstation (recommended method):
Back up the individual projects. To do this, open the Services application and select Data Backup -> Create -> Entire folders -> Projects.
You can back up several projects in a single operation.
Before you start, specify the backup folder on the network or on the local hard disk: Services application -> Configuration -> Backup path ->Browse for Folder.

The next step is to import the saved projects to the main workstation.To do this, open theServices application -> Data Backup -> Import -> Projects Before you import the individual projects, you can create new Allplan projects at the main computer. As an alternative, you can also create a new project during the import.

2.b: backing up projects of the individual workstations and importing them to the main workstation (special approach):
This approach should only be used with good reason for exceptional cases as it requires in-depth knowledge of Windows.
With this method, Windows Explorer is used to import the projects to the main workstation.
If some project names exist twice, you need to rename these projects before you back them up.

You can then rename the existing 'project.dat' file in the Prj folder of the main workstation.
Next, select the Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.
The system creates a new project administration file (project.dat), which should list all projects with names.

Now the main workstation contains the latest version of all the projects of the office.

3rd - merging project defaults
Open ProjectPilot at the individual workstations and copy the elements you want to transfer (symbols, smart symbols, lists, schedules, and so on) to the external path. Of course, you can set the external path to a common network folder that can be accessed by all workstations.
Next, open ProjectPilot at the main workstation and copy the contents of the external path to the office standard.

4th - data backup

  • Back up the projects, office standard and user settings at the main workstation:
    You can also copy the ..\prj (projects), ..\std (office standard) and ..\usr (user folder) paths to a backup folder (Nemsic, for example) on the hard disk.
  • In addition, you need to back up the ..\usr\local folder at every stand-alone computer.
  • Export the user interface setting of each user to a file: Allplan -> Tools - > Customize .... -> Export...


5th - uninstalling
Remove Allplan from all workstations.

6th - reinstalling
Before you install the same version again, create and share a folder (Nemdata, for example) on the future data server. Create a subfolder - Allplan - in this folder.

The next step is to reinstall the same version on all the workstations.

Specify the following installation paths:
Program folder:
local (C:\Programs\Nemetschek\Allplan, for example)
Central file storage folder:
Browse -> Network...
Find the sharedNemdata folder and select the Allplan folder.

After this, start installing.

7th - testing the start and restoring the backup
After the installation (check whether Allplan starts), copy the ..\prj and ..\std folders you backed up from the main workstation to the new ...\Nemdata\Allplan server folder.

Next, use Windows Explorer to copy the contents of the former user folder (…\usr\local) of the stand-alone workstation to the new user folder of the computer you just installed.

8th - updating the project administration file
Go to the project.datfile in the ...\Nemdata\Allplan\Prjfolder and rename itproject.alt.After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.

9th - summary
Now all the workstations access a common network drive with the same project pool and office standard.
With this type of installation, only one user can access a project at any one time. If several users are to work on a project at the same time, you need to install Workgroup Manager.

Загрузка PDF  FAQ_EN_Switching_from_single_installation_to_network...
Версия:  Allplan 2014 / Allplan 2013 / Allplan 2012  | Последнее изменение: 04.01.2018
5 user(s) found this FAQ helpful

Question:

After I have updated the driver of a graphics card from the Nvidia Quadro or GeForce series, I cannot start Allplan anymore.
I can see numerous error messages. What can I do?



Answer:

Allplan no longer starts after you have installed a current driver of the Nvidia GeForce or Nvidia Quadro WHQL series.


You can solve the problem as follows:

For customers running Allplan 2014:
Install at least version 2014-1-3. This version works with the drivers mentioned above.

For customers running Allplan 2013 or an earlier version:
Start the Services application.
Select Service -> Windows Explorer -> General program data.
(Allplan 2012: Services application -> Service -> Windows Explorer (program folder))
Open the ETC folder and then the "Shaders" folder, for example, C:\ProgramData\Nemetschek\Allplan\2013\Etc\Shaders.
Find the "Postprocess.frag" file and rename it "Postprocess.OLD".
Copy the "Postprocess.frag" file, which you can find attached to this FAQ, into the "Shaders" folder.

A note on Allplan 2014-1-3:
Download this version from Allplan Connect or from the FTP server.

Allplan Connect:
https://connect.allplan.com/de/support/downloads.html

FTP server:
ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de/download/Allplan/2014/CD/
Copy this link and paste it into the address bar of Windows Explorer. Then press ENTER.
This opens the folder on our FTP server.
Select the appropriate file (for example, 'DoWn-allplan2014-1-3_x64-cad.zip' for 64-bit systems) and select Edit -> Copy (Ctrl+C). (If you run the Windows 32-bit system, download the other file.)
Switch to a folder on your computer and select Edit -> Paste (Ctrl+V).
After having downloaded the file, you can decompress it and start installing it by double-clicking the exe file.
To download large files, you can also use a download client, such as Filezilla (http://filezilla-project.org/).

Загрузка PDF  FAQ_EN_Allplan_does_not_start_after_update_of_graphi... Загрузка Postprocess.frag
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Последнее изменение: 30.09.2020
1 user(s) found this FAQ helpful

Task:

Several users require Allplan administrator privileges in an installation with Workgroup Manager.



Note:

There are normal users and Allplan administrators in Allplan installations with Workgroup Manager.
Allplan administrators are:

  • Windows users with any login name who are granted administrative rights in the Workgroup Manager administration.

In other words, a Windows user with Windows administrator privileges does not necessarily have to be an Allplan administrator at the same time.

We do not recommend that several users work with Allplan administrator privileges at the same time, making it difficult to manage and protect the office standard, that is, the global settings. See solution 1.

However, if it is essential that several users are Allplan administrators, see solution 2.


Solution 1:

There is one Allplan administrator and normal Allplan users.

As the owner of a project has advanced rights in this project, you can define a user as the owner in a project and set the required resources to 'project'.
File -> New Project, Open Project... -> right-click the project you need -> Properties ... -> Path settings
Set the required resources to project.
You can also make these settings when you create a project or in ProjectPilot.

In addition to the Allplan administrator, another user (the owner of the project) can now define settings in the project.

Notes:

  • There are two standards for the definitions set to project: office and project.
  • It is only the Allplan administrator who can make changes in the office standard.



Solution 2:

Windows users with any login name are set up as Allplan administrators.


First, set up the Windows user as an Allplan user.
Services application -> Workgroup Manager -> Administrate users -> right-click->Create user

For the "user name", you can enter any Allplan user name, which can be up to 8 characters long.
For the "Windows user name", you must enter the name the user uses for login.
Important: If the user uses a domain for login, you must add it to the "Windows user name", for example, DOMAIN\user.

Grant the administration privilege to the "user group":
select "Administrator"on the dropdown menu. Using this approach, you can also assign the administration privilege to existing users.

Important: Click "Apply" and then "OK" to close the dialog box and the user overview, respectively.

Загрузка PDF  FAQ_EN_Several_users_with_Allplan_administrator_priv...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 23.09.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Why is it not possible to clear the check box for 'Find license server automatically' and why can't I enter an additional server name? These functions are grayed out.


Answer:

This problem is caused by Windows access rights. Only administrators can change these options.

Installing Allplan:
If this problem occurs during Setup and you cannot select a license, start by installing Allplan as a viewer.

Granting permissions later:
Assign full control to the users.
Local permissions prevent them from accessing the following file: Lic3LM.ini

Check whether the users have full control of the following folder:
Click folder with the right mouse button -> Properties -> Security -> Edit -> select the user - > grant full control

C:\ProgramData\Nemetschek(hidden file)

Open the 'License settings' dialog box: Services application -> Utilities -> License settingsYou should now be able to clear the check box and enter additional server names.