Question:

How can I work from home with Allplan without a direct LAN connection to a common file storage folder?



Answer:

1. Working from home with direct access to the central data


If you want to work together on projects, you can use Allplan Share, Allplan’s cloud solution, to work with Allplan without a LAN connection to the central file storage folder. This is only possible if Allplan is installed as a standalone version on a computer without access to a central file storage folder; otherwise, Allplan does not start. If the computer is part of a workgroup installation, the computer must be checked out and used outside the LAN (like a standalone workstation). Data access is via cloud services.
This is only possible if you use Allplan Share for cloud storage.

Working with Allplan Share is just as simple as working at a standalone workstation. You and several other users can access and edit a project at the same time.

To get more information on Allplan Share, use the following link or contact your sales partner:

https://www.allplan.com/de/add-ons/allplan-share/


You can also find further information on Allplan Connect; use the following link:


https://connect.allplan.com/de/forum/themen/topic/topics/cad-allgemein-1/moderierter-sammelbeitrag-zugriff-auf-allplan-projekte-aus-dem-homeoffice-via-allplan-share.html


Note:

VPN is not useful for common project storage.
Allplan exchanges many files with the data server. VPN uses advanced encryption, which considerably slows down data transfer.
A connection via VPN is not approved for Allplan because data might get damaged even if the connection is interrupted only briefly. In addition, working over the internet is extremely slow if the internet connection is not fast enough (at least 100 Mbit).
Allplan does not support a VPN connection with IPv6; Allplan detects only IPv4.
Make sure that the VPN connection does not switch to sleep mode.

Please note that we cannot provide support for this constellation.



2. Working from home without access to the central file storage (working locally):



2.1 Allplan with workgroup manager:

If workgroup manager is included in your license, you can check out a computer or laptop with projects from the workgroup environment. You can then work from home without access to the server. The projects on the computer or laptop that is checked out are locked for the CAD users on the network. These users see the comment you entered when you checked out the computer.

You can find instructions at

https://connect.allplan.com/en/faqid/20160923105251.html

When you use a license server, you can get the license via a VPN connection or borrow the license beforehand:

https://connect.allplan.com/en/faqid/20180109095437.html
https://connect.allplan.com/en/faqid/20160523165423.html




2.2 Allplan without workgroup manager:

Using the office computer
If you have neither workgroup manager nor network access, you must uninstall Allplan and install it again by specifying the local paths. To work with a project, you must back it up and then import it to the local installation.

Using a new (private) computer
If you want to use a new computer to work from home, you must return the license at the office computer and then use this license to install Allplan on the new computer.


We recommend that you do not mix data from the office computer and the private computer. Merging data later involves considerable time and effort.

Use the following link to find out how to transfer projects:

https://connect.allplan.com/en/faqid/20180507154505.html

Загрузка PDF  FAQ_EN_Working_with_Allplan_from_home.pdf
Версия:  Allplan 2021  | Последнее изменение: 16.12.2020
 

Information:

This document provides additional information on installing Allplan 2021.

Data backup/archiving:

We strongly recommend that you perform a complete data backup and archive this data before you upgrade to Allplan 2021!


Installation Instructions:


Detailed installation instructions can be found in the following places:

- If you have downloaded and unpacked Allplan 2021, you will find the file install.chm in the folder C:\Users\Public\Documents\Allplan 2021\HelpFiles\English


Please read these before installing Allplan 2021.

System requirements Allplan 2021

https://connect.allplan.com/de/faqid/20200930085615.html

Licenses when upgrading to Allplan 2021

https://connect.allplan.com/en/faqid/20200821110044.html


Extract from the installation instructions (see above)

If you want to switch from Allplan 2018/2019/2020 to Allplan 2021, you have three basic installation options.

1. New installation

Allplan 2021 is installed in a new folder. Any existing installations of Allplan (2020 or older) are not affected. No data and settings are transferred to the new installation.

The following options are available for transferring data later:

Uninstall Allplan 2021 and then upgrade Allplan 2018/2019/2020.
Integrating the data by hand (administrator knowledge required).

2. New installation with data copy from version

Allplan 2021 is installed in a new folder. Any existing installations of Allplan (2020 or older) are not affected. The office standard (\std), projects (\prj) and user data (\usr) can be automatically copied from an existing version 2018/2019/2020 to the new installation folder.
In this way, you can create a duplicate dataset if necessary: all projects, standards and resources can be used in both Allplan 2021 and 2018/2019/2020. This allows you to test the transition to the new version in real life, while the existing Allplan installation remains fully functional.
Note, however, that this method of working should avoid parallel processing of data in both installations, as the subsequent merging is time-consuming.

2a. Continuation of new installation with data copy from version

This option is available if a new installation with data copy has already been performed on another computer accessing the same data server and therefore the data has already been transferred.

3. Upgrade with data transfer from version 2018/2019/2020

Allplan 2021 is installed in an existing folder. The existing installation of Allplan 2018/2019/2020 is converted to Allplan 2021 and all important settings are transferred (see also Limitations for Data Transfer). Allplan 2018/2019/2020 is then no longer available.
Any existing installations older than Allplan 2018 are not affected.


Network Installations:

For network installations (shared 'central file storage folder'), only one main release version can be used - all workstations must be brought to Allplan 2021. Before starting the installation, make sure that all workstations have upgrade authorization. A mixed installation of different main versions is not technically approved. Complications that may arise are not covered by the maintenance contracts.

During the upgrade, no workstation may be running any version 2020, 2019 or 2018.

In case of an installation with Workgroupmanager all workstations must be checked in during the upgrade.




Data Conversion:

Data from older Allplan versions must be converted to version 2021. This happens automatically for projects opened in Allplan 2021. For instructions on how to convert all projects at once, click here:

https://connect.allplan.com/de/faqid/20090408124904.html

Загрузка PDF  FAQ_EN_Hotletter_2021.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Последнее изменение: 05.10.2020
 

Question:

I just installed an upgrade. How can I convert all the projects at once?



Answer:

Back up all the projects beforehand!

Do the following:

  • Exit Allplan on all workstations.
  • Only when working with Workgroup Manager:
    Log in as the Allplan administrator (sysadm).
  • Start the Services application.
  • Only when working with Workgroup Manager:
    Make sure all the computers where projects are located are up and running.
    To check this, select:
    Services application -> Workgroup Manager -> Information -> Display Project List(the second column displays the computer where the project is located).
  • Go to the computer where you want to convert the data and set the drawing file size to the maximum value:
    Services application->Service ->Hotline Tools->docsize ->512 (or 1024, if available) ->OK
    Note:
    After data conversion, you can set the drawing file size back to the initial value.
  • Start converting the data (use the computer where you have changed the drawing file size):
    Services application ->Service ->Hotline Tools -> datwaprjs: convert data of all projects
    If you reply "Yes" at the following two prompts, the program will convert the data of all projects.



Notes:

The time it takes to convert the data depends on various factors:

  • Number of projects
  • Size of each project
  • Performance of the computer converting the data
  • Network performance


It is possible to start data conversion from several workstations at the same time.

Загрузка PDF  FAQ_EN_Converting_all_Allplan_projects_in_a_single_o...
Версия:  Allplan 2019  | Последнее изменение: 12.11.2018
 

Information:

This document provides further information on installing Allplan 2019.

Backing up and archiving data:

We strongly recommend that you back up and archive all your data before you upgrade to Allplan 2019.


How to install


You can find detailed instructions on how to install Allplan 2019 in the following places:

- After you have downloaded and unzipped Allplan 2019, you can find the ‘install.chm’ file in the following folder: C:\Users\Public\Documents\Allplan 2019\HelpFiles\English.

- Use the following link:
https://webdrive.allplan.com/s/4LrjrymoxESzC6p and open the General\Installation help\2019 folder.


Please read these instructions before you install Allplan 2019.

System requirements for Allplan 2019

https://connect.allplan.com/en/faqid/20180608093815.html

How to handle licenses when upgrading to Allplan 2019

https://connect.allplan.com/en/faqid/20180608092654.html



Some notes on installing Allplan 2019

If you want to switch from Allplan 2016/2017/2018 to Allplan 2019, you can choose between three installation options. We recommend using the second option: first-time installation and copy data from Allplan 2016/2017/2018.

1. First-time installation

This option installs Allplan 2019 to a new folder without affecting any other Allplan installation (2018 or earlier). Setup does not transfer any data or settings to the new installation.

If you want to transfer data later, you have the following options:

You can uninstall Allplan 2019 and then upgrade from Allplan 2016/2017/2018.
You can integrate the data manually (requires administrative knowledge).

2. First-time installation and copy data from version

This option installs Allplan 2019 to a new folder without affecting any other Allplan installation (2018 or earlier). You can configure Setup to automatically copy the office standard (\std), projects (\prj) and user data (\usr) from Allplan 2016/2017/2018 to the new installations folder.
This duplicates the data: You can use all projects, defaults and resources both in Allplan 2018 and in Allplan 2016/2017/2016. This way, you can test the new version without losing your 'old' Allplan version.
Bear in mind, though, that you should not mix data from different versions. Merging data later involves considerable time and effort.

2a. Continue with first-time installation and copy data from version

This option is available when you have already used the second installation option to install <Product_Version> to a computer that accesses the same data server. As a result, the data are already available.

3. Upgrade and transfer data from Allplan 2016/2017/2018

This option installs Allplan 2019 to an existing folder, converting Allplan 2016/2017/2018 to Allplan 2019 and transferring all important settings. Afterwards, you can no longer work with Allplan 2016/2017/2018.
This does nor affect earlier Allplan versions (Allplan 2015 or earlier).


Installing on a network:

  • If you work in a network environment (one common central file storage folder), you must upgrade all workstations to Allplan 2019. Beforeyou start installing, make sure that all workstations can be upgraded. For technical reasons, it is not possible to mix installations of different major releases. Any related problems area not covered by service contracts.
  • During the upgrade, Allplan 2016/2017/2018 must not be running on any workstation.
  • When installing with Workgroup Manager, make sure all workstations are checked in before you start upgrading.





Converting the data:

Data from earlier Allplan versions need to be converted to version 2019. Allplan 2019 automatically converts the data of a project you open. Click here for instructions on how to convert all projects in a single operation:

https://connect.allplan.com/en/faqid/20090408124904.html


IBD 2019

Click here for instructions on how to get your activation codes for Allplan IBD:

https://connect.allplan.com/en/faqid/20110912113530.html

Загрузка PDF  FAQ_EN_Hotletter_2019.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 30.09.2020
 

Question:

How can I make several projects available to users when Workgroup Manager is installed?



Answer:

You can make several projects available to a user or define a user as the project owner of several projects.

Do the following:

First, log in as the Allplan administrator.
If necessary, set up an Allplan user for the new Windows user: Services application -> Workgroup Manager -> Configuration -> Add a user
(Allplan 2014 and later:Services application -> Workgroup Manager ->Administer users)

Start Allplan and then ProjectPilot by clicking
File -> ProjectPilot

Open the Projects folder in the area on the left.
You can see all the projects in the Contents of "Projects" area on the right.

a. Making several projects available to users:
In the area on the right, select the projects to which you want to add users or from which you want to remove users (CTRL or SHIFT key or use a selection rectangle).

Click one of the selected projects with the mouse button. On the shortcut menu, click
Add / remove authorized users...
The Add / Remove Authorized Usersdialog box opens.

Select the users you want to add to or remove from the selected projects.
Note:
The user list displayed only helps you select users. It does not list all the authorized users currently assigned to projects.

Click Addor Remove.
This adds or removes the selected users to or from the selected projects. Whether users you have already added to a project are added again is irrelevant. The same applies if you remove users you have never added to a project.

b. Defining a project owner for several projects
In the area on the right, select the projects for which you want to define the owner (CTRL or SHIFT key).

Click one of the selected projects with the mouse button. On the shortcut menu, click
Change project owner...
The Define Owner dialog box opens.

Select the user you want to define as the owner of the selected projects.
Note: The user list displayed helps you select users. You can define only one user as the owner.

Click OK.

c. Defining a project owner for a project or making a project available to several users(also applies to earlier versions):
In ProjectPilot in the area on the right, click the relevant project with the right mouse button. On the shortcut menu, click Properties.
The Properties for <project name>dialog box opens. Switch to the Security tab and define the owner and the authorized users.



Note:

You can add or remove project users or define the project owner only if the projects in question are in the current Allplan format.

Загрузка PDF  FAQ_EN_Making_several_projects_available_to_users.pd...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012  | Последнее изменение: 30.01.2020
 

Task:

You have installed Allplan on several local workstations. Now you want to change the installation so that you can access a common network drive.



Note:

Before you switch to a network installation, it is essential that you back up all the data of all the workstations.
We strongly recommend that you take advantage of the expertise of Nemetschek’s technical support staff. We are happy to help you!



Solution:

The following description shows how to change several workstations where Allplan is installed locally and the project data is also stored locally on each computer to workstations with a common network drive without Workgroup Manager.

1st - getting ready
Choose one of the workstations where you will install all the projects and the office standard (hereinafter referred to as the main workstation).
First, move all the projects to the main workstation.

1.a: copying resources into projects
To make sure that the projects in your office have a uniform appearance, change the path settings for the projects&apos; resources to &apos;Project&apos;.
Make the following setting for each project:
Allplan -> File menu -> ProjectPilot - Admin -> select the individual projects one after the other -> right mouse button -> Properties -> Settings tab
Set the path settings for &apos;Pen and line definitions&apos;, &apos;Fonts&apos;, &apos;Patterns, hatching styles, area styles&apos;, &apos;Bar and mesh cross-section catalogs&apos;, &apos;Layer structures, line styles, drawing types&apos; and &apos;Attributes proposed&apos; from &apos;Office&apos; to &apos;Project&apos;, if necessary.
The corresponding elements are copied from the office standard directly to the project. This ensures that the project settings stay the same even when you copy the project to the new server with the new office standard.

1.b: same folder name as project name
Open the &apos;General&apos; tab and select the &apos;Same folder name as project name&apos; setting if you want to proceed as described in 2b.

1.c: pen color ("Color stands for pen")
The pen color for the "Color stands for pen" setting is a user-specific setting that is not saved in the project but in the user folder (...\Usr).

2.a: backing up projects of the individual workstations and importing them to the main workstation (recommended method):
Back up the individual projects. To do this, open the Services application and select Data Backup -> Create -> Entire folders -> Projects.
You can back up several projects in a single operation.
Before you start, specify the backup folder on the network or on the local hard disk: Services application -> Configuration -> Backup path ->Browse for Folder.

The next step is to import the saved projects to the main workstation.To do this, open theServices application -> Data Backup -> Import -> Projects Before you import the individual projects, you can create new Allplan projects at the main computer. As an alternative, you can also create a new project during the import.

2.b: backing up projects of the individual workstations and importing them to the main workstation (special approach):
This approach should only be used with good reason for exceptional cases as it requires in-depth knowledge of Windows.
With this method, Windows Explorer is used to import the projects to the main workstation.
If some project names exist twice, you need to rename these projects before you back them up.

You can then rename the existing &apos;project.dat&apos; file in the Prj folder of the main workstation.
Next, select the Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.
The system creates a new project administration file (project.dat), which should list all projects with names.

Now the main workstation contains the latest version of all the projects of the office.

3rd - merging project defaults
Open ProjectPilot at the individual workstations and copy the elements you want to transfer (symbols, smart symbols, lists, schedules, and so on) to the external path. Of course, you can set the external path to a common network folder that can be accessed by all workstations.
Next, open ProjectPilot at the main workstation and copy the contents of the external path to the office standard.

4th - data backup

  • Back up the projects, office standard and user settings at the main workstation:
    You can also copy the ..\prj (projects), ..\std (office standard) and ..\usr (user folder) paths to a backup folder (Nemsic, for example) on the hard disk.
  • In addition, you need to back up the ..\usr\local folder at every stand-alone computer.
  • Export the user interface setting of each user to a file: Allplan -> Tools - > Customize .... -> Export...


5th - uninstalling
Remove Allplan from all workstations.

6th - reinstalling
Before you install the same version again, create and share a folder (Nemdata, for example) on the future data server. Create a subfolder - Allplan - in this folder.

The next step is to reinstall the same version on all the workstations.

Specify the following installation paths:
Program folder:
local (C:\Programs\Nemetschek\Allplan, for example)
Central file storage folder:
Browse -> Network...
Find the sharedNemdata folder and select the Allplan folder.

After this, start installing.

7th - testing the start and restoring the backup
After the installation (check whether Allplan starts), copy the ..\prj and ..\std folders you backed up from the main workstation to the new ...\Nemdata\Allplan server folder.

Next, use Windows Explorer to copy the contents of the former user folder (…\usr\local) of the stand-alone workstation to the new user folder of the computer you just installed.

8th - updating the project administration file
Go to the project.datfile in the ...\Nemdata\Allplan\Prjfolder and rename itproject.alt.After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.

9th - summary
Now all the workstations access a common network drive with the same project pool and office standard.
With this type of installation, only one user can access a project at any one time. If several users are to work on a project at the same time, you need to install Workgroup Manager.

Загрузка PDF  FAQ_EN_Switching_from_single_installation_to_network...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Последнее изменение: 30.09.2020
 

Task:

Several users require Allplan administrator privileges in an installation with Workgroup Manager.



Note:

There are normal users and Allplan administrators in Allplan installations with Workgroup Manager.
Allplan administrators are:

  • Windows users with any login name who are granted administrative rights in the Workgroup Manager administration.

In other words, a Windows user with Windows administrator privileges does not necessarily have to be an Allplan administrator at the same time.

We do not recommend that several users work with Allplan administrator privileges at the same time, making it difficult to manage and protect the office standard, that is, the global settings. See solution 1.

However, if it is essential that several users are Allplan administrators, see solution 2.


Solution 1:

There is one Allplan administrator and normal Allplan users.

As the owner of a project has advanced rights in this project, you can define a user as the owner in a project and set the required resources to &apos;project&apos;.
File -> New Project, Open Project... -> right-click the project you need -> Properties ... -> Path settings
Set the required resources to project.
You can also make these settings when you create a project or in ProjectPilot.

In addition to the Allplan administrator, another user (the owner of the project) can now define settings in the project.

Notes:

  • There are two standards for the definitions set to project: office and project.
  • It is only the Allplan administrator who can make changes in the office standard.



Solution 2:

Windows users with any login name are set up as Allplan administrators.


First, set up the Windows user as an Allplan user.
Services application -> Workgroup Manager -> Administrate users -> right-click->Create user

For the "user name", you can enter any Allplan user name, which can be up to 8 characters long.
For the "Windows user name", you must enter the name the user uses for login.
Important: If the user uses a domain for login, you must add it to the "Windows user name", for example, DOMAIN\user.

Grant the administration privilege to the "user group":
select "Administrator"on the dropdown menu. Using this approach, you can also assign the administration privilege to existing users.

Important: Click "Apply" and then "OK" to close the dialog box and the user overview, respectively.

Загрузка PDF  FAQ_EN_Several_users_with_Allplan_administrator_priv...
Версия:  Allplan 2017  | Последнее изменение: 09.10.2017
 

Information:

This document provides further information on installing Allplan 2017.

Backing up and archiving data:

We strongly recommend that you back up and archive all your data before you upgrade to Allplan 2017.


How to install:


You can find detailed instructions on how to install Allplan 2017 in the following places:

- After you have downloaded Allplan 2017, you can find the install.chm file in the Helpfiles\English folder.
- You can find the install.chm file on the Allplan 2017 DVD in the following folder: <DVD>:\programs\x64\Allplan\Helpfiles\English.

Please read these instructions before you install Allplan 2017.

Some notes on installing Allplan 2017

If you want to switch from Allplan 2014/2015/2016 to Allplan 2017, you can choose between three installation options. We recommend using the second option: first-time installation and copy data from Allplan 2014/2015/2016.

1. First-time installation

This option installs Allplan 2017 to a new folder without affecting any other Allplan installation (2016 or earlier). Setup does transfer neither data nor settings to the new installation.

If you want to transfer data later, you have the following options:

You can uninstall Allplan 2017 and then upgrade from Allplan 2014/2015/2016.
You can integrate the data manually (requires administrative knowledge).

2. First-time installation and copy data from Allplan 2014/2015/2016

This option installs Allplan 2017 to a new folder without affecting any other Allplan installation (2016 or earlier). You can configure the program to automatically copy the office standard (\std), projects (\prj) and user data (\usr) from Allplan 2014/2015/2016 to the new installations folder.
This duplicates the data: you can use all projects, defaults and resources both in Allplan 2016 and in Allplan 2014/2015/2016. This way, you can test the new version without losing your &apos;old&apos; Allplan version.
Bear in mind, though, that you should not mix data from different versions, as merging data later involves considerable time and effort.

2a. Continue with first-time installation and copy data from version

This option is available when you have already installed <Product_Version> and copied the data to a different computer that accesses the same data server. As a result, the data have already been transferred.

3. Upgrade and transfer data from Allplan 2014/2015/2016

This option installs Allplan 2017 to an existing folder, converting Allplan 2014/2015/2016 to Allplan 2017 and transferring all important settings. Afterwards, you can no longer work with Allplan 2014/2015/2016.
This does nor affect earlier Allplan versions (Allplan 2013 or earlier).



Installing on a network:

  • If you work in a network environment (one common central file storage folder), you must upgrade all workstations to Allplan 2017. Therefore, make sure you can upgrade all workstations (deadline for Serviceplus agreement: July 1, 2016) beforeyou start installing.
  • During the upgrade, Allplan 2014/2015/2016 must not be running on any workstation.
  • When installing with Workgroup Manager, make sure all workstations are checked in before you start upgrading.



Converting data:

IBD 2017

IBD 2017 is expected to be released with the Allplan 2017-0-1 Hotfix at the end of July 2016.
https://connect.allplan.com/en/faqid/20160707142752.html


Загрузка PDF  FAQ_EN_Hotletter_2017.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Последнее изменение: 16.10.2020
 

Question:

How can I install additional Allplan workstations on an existing network (with or without Workgroup Manager)?



Answer:

Before you install the additional workstations, find out the path to the central file storage folder on a computer where Allplan has already been installed. Open the Services application on this computer. The Services application window shows the path to the central file storage folder.

Enter this path when Setup prompts you to specify the central file storage folder.
Select "Minimum" for the Setup type.



Notes:

  • Make sure the version you are installing is the same as the one installed on the other workstations.
  • In addition, make sure all workstations are running either with Workgroup Manager or without Workgroup Manager. To find out whether Workgroup Manager is installed or not, open the Services application and check the menus: if you can see the Workgroup Manager menu, Workgroup Manager is installed.
  • Installing additional workstations does not affect the data (projects, ...) in the central file storage folder.
  • If you add new users to a new Allplan workstation, do not forget to add them to the Workgroup Manager, too.
  • Version 2014 and earlier: if one of the computers also serves as the Allplan server, you cannot use the approach described above to find out the path to the central file storage folder.
    In this case, you will see the path to a local folder instead of the central file storage folder.
    Use a different computer to find out the path to the central file storage folder.
Загрузка PDF  FAQ_EN_Installing_Allplan_on_a_network_later.pdf ...
Версия:  Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Последнее изменение: 08.05.2019
 

Question:

I have installed Allplan using the temporary Softlock license ("customer#_seat_psd.nslock") and "Trial" is displayed for its status in the License Manager.
How can I register this license?



Answer:

You use License Manager to create a registration request and send it by email to register@nemetschek.de.
In response, you get a final license file. Installing this license removes the lime limit.
Below is a description of the necessary steps.



Notes:

  • Using the temporary license, you can start Allplan as a trial version. You can work with Allplan without any restrictions for 30 days.
    After expiration of this period, Allplan starts as a viewer only. However, you can still request and install the final license.
  • When running Windows Vista, start Nemetschek License Manager as the administrator:
    Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager
    Click "License Manager" with the right mouse button and choose "Run as administrator" on the shortcut menu.




How to proceed:

1. Request a license registered for your computer

  1. On the Windows taskbar, click Start - (All) Programs - Nemetschek - Nemetschek Softlock 2006 - License Manager(or Services application -> Utilities -> License -> License Manager (NemSLock)).

    When running Windows Vista, start License Manager as the system administrator: click Start - (All) Programs - Nemetschek - Nemetschek Softlock 2006 - License Manager.
    Click License Managerwith the right mouse button. On the shortcut menu, click Run as administrator.
  2. Select the seat you want to register so that it is highlighted in blue.

    Note:You can only register seats you have purchased. If you can see only seats with numbers between 90 and 99 (= trial licenses for temporary use), you first need to install the personal license for temporary use.
  3. Click License requestat top left.

    The License Request Wizardstarts. The Welcome to the license request wizarddialog box provides information on the steps that follow.
  4. Click Next >.
    The Customer detailsdialog box opens.

    Note: Editing customer details requires administrator privileges. If you do not have these privileges, you will see a corresponding message. Cancel NemSLock License Manager and start again by selecting the Run as administrator option on the shortcut menu.
  5. Enter the necessary details:

    - If the Client IDhas eight zeros (00000000) and the CD Keyhas eight capital F&apos;s (FFFFFFFF), you selected the Trial license for temporary useoption when you installed Allplan.
    In this case, install the personal license for temporary use before you create the registration request.

    - If Client IDand CD Keydo not match the numbers printed on your delivery note (for example, typing errors, small letters and capital letters mixed up), you can enter Client ID and CD Key manually.

    - Fill out all the fields.

    Make sure you enter your email address correctly, because registered licenses and replies to status queries of license will be sent to the address you specify here.

    Note:Check the entries for Client ID(customer number) and CD Key , making sure these numbers are the same as those printed on the delivery note you received from Allplan. The CD Keyusually consists of the numbers 0 to 9 and the capital letters A to F.

    Tip: You can also find these numbers in the personal license file for temporary use (*_psd.nslock). Open the license file in an editor and scroll down to the end of the file. You can then copy the license codes displayed after CUSTOMERand CDKEYto the Clipboard and paste them into the appropriate boxes.
  6. Click Next >.
  7. Select the Program, Versionand Seatand click Next >.

    Note: If the Client IDis invalid (for example, when you use a trial license) you cannot confirm the dialog box by clicking OK. Instead, you will see a corresponding message.
  8. Specify how to send the registration file and click Next >.

    Start email program ...
    The program creates and saves the register.txt file before it opens your default email program. The program automatically attaches the registration file to the email and enters register (please no spam) @ (please no spam) nemetschek.defor the address.

    Save the registration file ...
    The program creates and saves the register.txt file before it opens the folder with the registration file in Windows Explorer. Now you can use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer with Internet access and so on.

    In addition, you can see the data that were written to the registration file.
  9. Click Finish.
  10. Click Close to exit NemSLock License Manager.


You will receive a reply by email within a few minutes. This email provides information on the registration process and usually includes the registered license file.

Note: The registered license file is generated by an automated system. Consequently, any additional comments in incoming emails are not read. If you have any questions or need more information, please contact Allplan directly.



2. Install the license file

Shortly after you sent the registration request to &apos;register@nemetschek.de&apos; as described in step 1, the final license file will be sent to the email address you specified in the registration request.
Install this license file as follows:

  • Save the license file to any folder on the hard disk.
    If the license comes as a zip file, extract it.
  • Next, install the license file by double-clicking it ("customer#_seat.nslock").
    Confirm the dialog box.
  • As an alternative, you can also use License Manager to install the license file (Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager).
    Click "Install - Install license" at top left in Nemetschek SoftLock License Manager and select the license by clicking "Browse...".
    Click "Finish" to complete the installation process.


Note:

Do not use the same computer to register several license files for different seats. This would connect the seats. You cannot separate the seats again without the help of technical support.

Загрузка PDF  FAQ_EN_Nemetschek_Softlock_-_first_steps.pdf
1 - 10 (11)
https://connect.allplan.com/ uses cookies  -  More information

Accept