Question:

After crashing, Allplan does not start anymore. When you open license selection in the license settings, you can see the following message: "Cannot find a license for running Allplan." How to solve this problem?



Answer:

Restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



The crash causes this problem. The fact that the license is not available is a consequential error.

Note:

If Allplan crashes often,
send the following information by email to your Allplan Support:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a log file, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
Загрузка PDF  FAQ_EN_Allplan_does_not_start_after_crashing_-_canno...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 30.09.2020

Question:

Suddenly, one of the following error messages pops up: "This license is no longer available", "CmActLicense runtime system is not installed!" or "NemAll_DataResource20.dll: Start Error 102". After this, Allplan does not start anymore. How can I solve this problem?


Answer:

The local Windows service, which is used by licensing, is not running correctly.

If communication with the local Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So you need to exclude the "Codemeter" folder from virus scans.
You can find this folders in the following path:
C:\Program files (X86)\Codemeter
C:\Program files\Codemeter
C:\ProgramData\CodeMeter

Then restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



Important note:

Follow this link to find out how to configure the virus scanner in conjunction with real-time scanning. Exclude all Allplan folders with their subfolders from virus scans. You can display the paths to the Allplan folders in the Services application window.

https://connect.allplan.com/en/faqid/20091126145752.html


Загрузка PDF  FAQ_EN_Windows_service_for_licensing_is_blocked_by_v...
Версия:  Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Последнее изменение: 15.11.2017

Question:

How can I update cross-section catalogs or install country-specific cross-section catalogs in Allplan 2011 and later?



Answer:

To install and save cross-section catalogs in Allplan 2011 and later, select Tools -> Defaults -> Cross-Section Catalogs. A dialog box opens. You can find a folder symbol and a disk symbol at bottom left.

To install cross-section catalogs, use the folder symbol. Another dialog opens, where you can select the cross-section catalog file you want to install. Select the file to be installed and click "Open" to confirm. This installs the corresponding cross-section catalog, which you can now use in Allplan.
To install country-specific cross-section catalogs, select the "Ing" folder, which was created when you installed Allplan. You can find it in the Allplan installation path (e.g., c:\Nemetschek\Allplan 201x\New\Ing - more information on the Allplan installation path is provided below in the "Notes" section).
This folder includes the country-specify cross-section catalog files.

To save a custom cross-section catalog, use the disk symbol. Another dialog opens, where you can select any folder to save the cross-section catalogs currently used in Allplan.



Note:

To update cross-section catalogs, you may need administrator privileges. If necessary, log on as an administrator before you start the update.

To use the cross-section catalogs for a specific project only, set the path settings for the cross-section catalogs of this project to project before you install the cross-section catalogs. In Allplan, open the "File" menu and select "Open Project..." Click the corresponding project with the right mouse button. Select "Properties". A dialog box opens. In the "Path settings" area, set the "Bar and mesh cross-section catalogs" to "Project".

To determine the path where Allplan is installed, use the Services application and select Service -> Hotline Tools-> showcfg. The Services application window shows the path of the Allplan installation folder.

The following abbreviations are used for the country-specific cross-section catalogs in the file names (axyzqusr.txt):
aut Austria
bel Belgium
bra Brazil
bul Bulgaria
deu Germany
eng England
fra France
hol Holland
hrv Croatia
ita Italy
kor Korea
pol Poland
rum Romania
rus Russia
slk Slovakia
svn Slovenia
swi Switzerland
tch Czech Republic
ung Hungary
usa USA

Загрузка PDF  FAQ_EN_Updating_cross-section_catalogs_(Allplan_2011...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Последнее изменение: 25.11.2019

Question:

How can I permanently change the path settings presented for selection in specific tools (save, import)?



Answer:

When you save, import and export elements or files, Allplan automatically proposes a specific folder where the data is saved or taken from.
You can specify which Allplan file type is saved in which folder. These folders are automatically presented in the "Save" dialog box of the relevant file type. However, you can change them at any time.

To set this proposed folder on an individual basis, do the following:
Select the Tools menu ->Options... -> Desktop environment(Allplan 2009 and earlier: Tools -> Options... -> Global Options-> "Settings"tab).

You can click thePAah setting sbutton to the right of Folders for savingto define defaults. You can choose Project, Private, Custom or Last for the path setting:

  • Project: the file type is saved in the current project (not available for NDW and NPL files).
  • Private: the file type is saved in the user's private project.
  • Custom: you can specify any folder for the file type. To select the folder, click the path displayed in the Folder column and enter a new path or click ... in the Browse column and select the path in a dialog box.
  • Last: the file type is saved in the path you selected last.
Загрузка PDF  FAQ_EN_Default_path_settings.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 12.11.2020

Question:

Why is Allplan running so slow?


Answer:

Check the following points:

1. Current version
Make sure you work with the current Allplan version.

  • Do the following or ask your system administrator to do this:
    Open Allplan and click the ‘?’ icon in the upper right-hand corner. Click ‘Update Allplan’.
    Select 'Find now'. If Allplan finds updates or hotfixes, download the installation packages.
  • Deactivate the virus scanner while your are installing updates or hotfixes. This might require administrator privileges. Contact your system administrator if you have problems.
  • Right-click the Allplan icon on the desktop. A shortcut menu opens.
    Select ‘Run as administrator’ and click ‘Yes’ to confirm the following message.
    As a result, Windows security settings do not block the installation.



2. System requirements:
Check the hardware and software required for your Allplan computer.

2.a)Download and run the system test.
Check the notes.
https://www.allplan.com/de/system/systemvoraussetzungen/

2.b)Check the Allplan system requirements:
https://www.allplan.com/de/system/systemvoraussetzungen/

2.c)You can find information about graphics cards at
https://connect.allplan.com/de/support/grafikkarten.html

2.d)You can find server operating systems you can use for the central file storage of Allplan at
https://connect.allplan.com/en/faqid/20140924094923.html


3. Hotline tools:
Start the Services application, open the ‘Service’ menu and select ‘Hotline Tools’. To save your settings, select the following tools.

- savestd: Saves user defaults.
- savereg: Saves CAD registry settings.

Start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:

- cleanup: Initializes the display.
- cleanstd: Resets CAD defaults.
- cleanreg: Resets CAD registry settings.

Check whether this has solved the problems.
If this is not so, restore the settings you just saved. To do this, start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:
- reststd: Restores saved user defaults.
- restreg: Restores CAD registry settings.


4. Color scheme selected in Allplan:
Start Allplan, open the ‘View’ menu, point to ‘Toolbars’ and select ‘Customize User Interface’. Open the ‘Customize’ tab and set ‘Color scheme and icon design’ to ‘Windows’.


5. Check the availability of all projects that are not online (if you use Workgroup Manager):
Start Allplan, open the ‘File’ menu and select ‘New Project, Open Project’. Deactivate ‘Check availability of all offline projects’.


6. Virus scanner
Check whether an anti-virus program is running in the background of the computer or server.
If so, reduce protection to "programs only".

Scanning "all files" can take a long time, considerably slowing down your computer when you switch between projects or exit the program.
You can exclude the Allplan installation folders from real-time scanning.When you start the Services application, you can see a list of the folders to be excluded.
You can find more information at
https://connect.allplan.com/en/faqid/20091126145752.html
Changes in the settings of the virus scanner only come into effect when you re-start the computer.


7. Aero desktop effects
Deactivate the Aero desktop effects of Windows.
To do this, open the Control Panel, select ‘Ease of Access’ and go to the ‘Make things on the screen easier to see’ area.
Select the ‘Turn off all unnecessary animations (when possible)’ option.


8. Name resolution on the network
If Allplan takes several minutes to start, name resolution on the network may not work.
To check this, do the following:
Right-click the Windows Start Button, select ‘Run’, type in ‘cmd’, click OK, type in ‘Nslookup’ and press ENTER.
Go to the line following the > character, type in the name of the Allplan data server and press ENTER.
The reply starts with the name and address of the server providing name resolution.
You can find the name and address of the Allplan data server in the second group.
If problems occur, contact your network administrator and ask him or her to configure name resolution correctly.


9. Speed of Allplan projects
Check whether some Allplan projects are slower than other Allplan projects.
Start with the empty project and check whether it is slow too.
After this, select any other Allplan project.

If it is only the current project that is slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


10. Network: checking out Allplan using Workgroup Manager
If you use Allplan with Workgroup Manager, you can check whether the problems are caused by the network. To do this, check out the workstation with the project in question and use the project on the local Allplan workstation.
You can find detailed information on checking out an Allplan workstation using Workgroup Manager in the
Services application. Open the ‘Help’ and select ‘Workgroup Manager’.

After you have checked out the workstation, Allplan no longer accesses the central file storage of the server.
If this has solved the problems, they are caused by the network. In this case, the network must be checked in detail.
Contact your network administrator and ask him or her to do this.

If the project is still slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


11. Log files and system information files
If all the points above do not solve the problems, technical support requires more system information about the computer running Allplan.

  • So, we would be grateful if you could send us a support request (Allplan Hotinfo with Allplan logging).
    To create a support request, start the Services application, open the ‘Service’ menu and select ‘Create support request (Hotinfo)’.
    Several dialog boxes open. Select ‘Technical Support Allplan’ and ‘Enquiry with Allplan logging’. Enter all the data required. Finally, click ‘Finish’.
    Another dialog box opens, prompting you to start Allplan. Click the ‘Start Allplan’ button.
    Allplan starts, logging all processes.
    Try to reproduce the problem as exactly as possible.
    Exit Allplan as soon as possible, reducing the data in the log file to a minimum.
    Then click ‘Next’ to generate the support request with the log file.
    You can find more information about Hotinfo at
    https://connect.allplan.com/en/faqid/20140528094911.html
  • To analyze the Windows system environment, we would ask you to send us the logs created by Windows Event Viewer of your computer.
    To start Windows Event Viewer, right-click the Windows Start Button, select ‘Run’ and type in ‘eventvwr.msc’.
    You can also type in ‘Event Viewer’ in the search box of Windows. This displays the link file to the Windows event logs.
    Using Event Viewer, create *.evtx files for the application log and the system log in the ‘Windows Logs’ area and for the ‘Administrative Events’ log in the ‘Custom Views’ area.


Please send us the files.

Загрузка PDF  FAQ_EN_Allplan_is_running_slow.pdf
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 12.11.2020

Question:

How can I change the cache path for Allplan Share?

Note:

You do this at your own risk.
We strongly recommend that you clarify all issues in advance.
Always copy a file before you change it.
Before you change registry entries, back up the registry key that you want to modify. To do this, export the key by selecting File - Export in the Registry Editor.

Answer:

Allplan Share temporarily saves the project data in the path of the local file storage, which you defined when you installed Allplan.
You can see the path of the local file storage folder in the Services application.
If this folder is centrally on a server for all Allplan workstations:
To avoid replication conflicts that might occur when several users work on the same project data, you must change the path settings for each user so that this folder is locally on the user’s computer running Allplan.

Before you start, close Allplan, making sure that you do not lose any data.

  1. Go to a local drive (C or D) of the computer running Allplan and create the new "Local data” folder with the "Allplan” subfolder (for example, C:\Local data\Allplan).
  2. Start the Windows Registry Editor as the administrator (start - run - regedit).
  3. Go to the left column of Registry Editor and open the following key: HKEY_LOCAL_MACHINE\SOFTWARE\Nemetschek\Allplan\2018.0\InstallRoot. If Allplan 2019 or a newer Allplan version is installed, “2019.0“ or the newer version replaces “2018.0” in the path.
  4. Go to the right column of Registry Editor and double-click theLocalDataDrivekey. Specify the drive that you selected for local file storage (for example, C:). Then click OK to confirm the change. This applies the change.
  5. Then, go to the right column of Registry Editor again and double-click theLocalDataPathkey. Specify the path that you defined for local file storage (for example,\Local Data\Allplan). Then click OK to confirm the change. This applies the change. The result should look like this:
  6. Close the Registry Editor. Allplan now uses the new path for the cache of Allplan Share.
  7. Start Allplan and select the Allplan Share project to load the necessary project data into the new cache.



Загрузка PDF  FAQ_EN_Adjusting_the_local_file_storage_folder_for_A...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 16.12.2020

Question:

What can I do if Allplan does not start?


Answer:


Work through the following steps:

Step 1 - run as administrator
Start Allplan with the ‘Run as administrator’ option.
To do this, right-click the Allplan icon and click ‘Run as administrator’.
If Allplan does not start, go to step 2.

Step 2 - cleanup
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanup -> OK
If Allplan does not start, go to step 3.

Step 3 - cleanstd
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanstd: reset CAD defaults -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the settings:
Services application -> Service -> Hotline Tools -> laststd: restore the last settings -> OK -> OK -> Yes -> OK
Go to step 4.

Step 4 - cleanreg
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanreg: reset CAD registry settings -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the registry settings:
Services application -> Service -> Hotline Tools -> lastreg:restore most recent CAD registry settings -> OK -> OK -> Yes -> OK
Go to step 5.

Step 5 (Allplan 2016 and later)
Restart the Wibu service:
Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.

If Allplan does not start, go to step 6.

Step 6 (Allplan 2016 and later)
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.htmlor on the Nemetschek FTP server ftp://nemhotline:ha37jvg8f@ftp.nemetschek.deat download/General/Wibu/CodemeterRuntime.exe

Start the ‘CodeMeterRuntime.exe’ file.
To do this, right-click this file and select
‘Run as administrator’.
Confirm all messages displayed and the defaults by clicking ‘Next’.
CodeMeter Control Center will be installed afterwards.
If Allplan does not start, go to step 7.

Step 7 - contact Technical Support
Send the following information by email to support.de@allplan.com:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
  5. Allplan 2016 and later -> a screenshot of the Wibu Control Center. To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.


We will contact you.

Загрузка PDF  FAQ_EN_Allplan_does_not_start.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Последнее изменение: 30.12.2020

Question:

What can I do if Allplan no longer starts after I have upgraded and the following messages appear?
Allplan
Stop

...

After this, Quality Reporter displays an error report.



Answer:

Exit Allplan on all workstations and do the following:
Open the Services application and make a note of the path to the 'central file storage folder', which is displayed in the Services application window.
In addition, check whether the workgroup manager line is followed by 'Yes' or 'No'.

Open the central file storage folder in Windows Explorer.

If the workgroup manager line is followed by
'Yes', open the NET subfolder.
'No', open the PRJ subfolder.

Find the 'project.dat' or 'project.Dat.xm' file in the NET or PRJ folder and rename it 'project-old.dat'.

After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> OK -> Restore project management file -> OK
The program creates a new, correct project management file and you can start Allplan again.



Note:

If you come across error messages while doing this, please email the following information to support@allplan.com:

  1. Describe exactly what you did before the error or crash occurred.
  2. The error message itself (as a screenshot).
  3. The log file (trace).
    https://connect.allplan.com/en/faqid/0001a27a.html
  4. A Hotinfo support request with question 01.
    https://connect.allplan.com/en/faqid/20130823123806.html
Загрузка PDF  FAQ_EN_Allplan_does_not_start_after_upgrade_Stop_mes...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Последнее изменение: 01.10.2020

Question:

How can I temporarily borrow a license for a client from the license server?



Answer:

To borrow a license, do the following:

Notes:
You cannot borrow licenses on the license server. You can do this only at the clients.
You can only borrow and return a license if the client is connected with the license server.
Computers that are not on the company network must use a VPN connection to access the server.

At the client:

  • Open the 'License settings' dialog box: Services application -> Utilities -> License settings.
  • Click License selectionon the left. Then click the license you want to borrow so that this license is highlighted in blue.
  • If this license is a license server license, the Todayand Borrowbuttons in the 'Borrow license for:' area are no longer grayed out.
  • The Todaybutton always shows the preset period of time. The default setting is Today. If you want to change the period of time, click the Todaybutton. You can then choose from various options.
    Note: When you select 'Today', the license will be available again for all Allplan users on the server tomorrow.
    When you select a number of days, borrowing will always be valid for 24 hours. For example, you borrow a license for 1 day and borrowing starts at 3 o'clock in the afternoon, the license will not be available on the server until 3 o'clock in the afternoon. The same applies to selecting days on the calendar.
  • After having specified the correct period, click Borrowto borrow the license at once.


You can immediately see the borrowed license in the license selection below your computer name. Click the green information button to get details about this license. For example, you can see when the borrowed license will automatically be returned to the server.

  • If you want to return the license to the server before the time period expires, click the license again so that it is highlighted in blue. The Return licensebutton is now available. Click Return licenseto immediately return the selected license to the server.


Загрузка PDF  FAQ_EN_License_server_-_borrowing_licenses_temporari...
Версия:  Allplan 2021  | Последнее изменение: 14.12.2020 14:33

The original FAQ contains pictures. Use the PDF link to get the complete presentation.

Question:

What does this error message mean and how can I fix it? How can I change the
path and switch from server to local?

Response:

For the use of Allplan Share, a defined path for the "LocaldataPath" is used
for the temporary storage of the project data to be edited. In Allplan 2021, a
default setting was made so that the LocaldataPath should always be in the
Windows user folder. However, for customers who place their users on the
server, this causes the problem that 80 characters are exceeded.
Since hotfix 2021-0-3 there is a possibility to change this path to local by
creating a registry entry.


Note:

The procedure described below is done at your own risk.
Questions about this should be clarified before the practical implementation.
Always make a copy of a file before making any changes to it.
Before changing registry entries, create a backup of the registry key to be
modified by exporting the key in the registry editor under File->export.
We recommend that you have this work done by an experienced technician.


After you have installed at least version 2021-0-3 of Allplan, proceed as
follows:

Be sure to exit Allplan before making the change to prevent data loss and
errors.

On a local C: or D: drive of the computer used for Allplan, create a new folder
with the name "Local data" and the subfolder "Allplan" (e.g. C:\Local
data\Allplan) .
In Windows, as an administrator, start the Windows Registry Editor (Start->
Run-> Regedit) .
In the registry, in the left column, open the key:
HKEY_LOCAL_MACHINE\SOFTWARE\Nemetschek\Allplan\2021.0\InstallRoot.
In the right window, right-click and select New -> String Value. Create a
string value with the names LocalDataDrive and a string value with the name
LocalDataPath.
Now activate the edit mode for the "LocalDataDrive" key in the right column of
the registry editor by double-clicking the left mouse button and enter here
only the drive you have chosen for the local file storage (e.g. C: ) and
confirm the change with "OK". Thus the change is taken over in the registration
editor.
Then activate the edit mode for the "LocalDataPath" key in the right column of
the registry editor by double-clicking the left mouse button and enter the
additional path defined for the local file storage (e.g. \LocalDataPath ) and
confirm the change with "OK". The change will be applied to the registry
editor. The result should look as follows:



Close the registration editor. Allplan now uses the newly defined path for the
Allplan Share cache.
Restart the Allmenu and you will see the local path displayed there.

Загрузка PDF  FAQ_EN_Error_message_LocalDataPath_exceeds_maximum_l...