Результат поиска

1 - 10 (16)
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 30.09.2020
4 user(s) found this FAQ helpful

Question:

How can I transfer the license permanently to a new computer?
How can I temporarily transfer the license of a registered computer to a different computer?
How can I interchange the licenses of two registered computers?



Answer:

If you activated the license online by entering a Product Key, you can return the Product Key and then use it for a different computer. You can return and activate the license only if the computers have Internet access. The computer where you want to return or activate the license does not have to be online all the time. It is enough if it is online while you are returning or activating the license.


Returning a license
To return a license in online mode

  • Open the 'License settings' dialog box: Services application -> Utilities -> License settings
  • Write down the Product Key for the license you are returning.
  • Click License activationon the left. Then click the license you want to return.
  • Click Return license.


You can now activate the license on a different computer.


Activating a license
If you want to transfer the license permanently, you can activate a license while you are installing Allplan or after you have installed Allplan. By activating a license, you connect the license with the new or other computer. As a result, you can start Allplan on this computer.
If you want to transfer the license only temporarily, install Allplan as a viewer on the second computer and
activate the license later.

To activate the license during installation:
Start Setup and follow the instructions displayed.

  • In the 'Installation Option' dialog box, select the 'Enter Product Key' option and click 'Next'.
  • Enter your Product Key.
  • Click 'Activate license'.


To activate the license after installation:

  • Open the 'License settings' dialog box: Services application -> Utilities -> License settings
  • Click License activationon the left.
  • Enter your Product Key.
  • Click Activate license.



Here comes a practical example:
If you want to use a Product Key for running Allplan on two or more computers, you must use computer A to return the license before you can use this license with computer B. To return the license, open the Services application -> Utilities -> License settings -> Return license. If this computer always uses the same Product Key, you can find this Product Key in the box below License activation. This box always displays the last Product Key entered.

If you switch between several licenses, it is a good idea to save the Product Keys used in a text file on the desktop. This way, you can copy the Product Keys quickly and easily to the license settings.


Note: When license cannot be returned due to defect
If your computer has a defect and does not start anymore, or your hard disk has crashed and you had to install a new one, we need a statutory declaration from you. You will receive this declaration after your situation has been checked by the technical support team. Please contact your local Allplan Support with a brief description of what happened.


Further Notes:
You can also find your Product Key in Allplan Connect. Go to http://connect.allplan.com/license
Click Profile -> License administration.
Only administrators can use this function.

Загрузка PDF  FAQ_EN_Transferring_license_to_a_new_or_another_comp...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 09.10.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

After crashing, Allplan does not start anymore. When you open license selection in the license settings, you can see the following message: "Cannot find a license for running Allplan." How to solve this problem?



Answer:

Restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



The crash causes this problem. The fact that the license is not available is a consequential error.

Note:

If Allplan crashes often,
send the following information by email to your Allplan Support:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a log file, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
Загрузка PDF  FAQ_EN_Allplan_does_not_start_after_crashing_-_canno...
Версия:  Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Последнее изменение: 15.11.2017
1 user(s) found this FAQ helpful

Question:

How can I update cross-section catalogs or install country-specific cross-section catalogs in Allplan 2011 and later?



Answer:

To install and save cross-section catalogs in Allplan 2011 and later, select Tools -> Defaults -> Cross-Section Catalogs. A dialog box opens. You can find a folder symbol and a disk symbol at bottom left.

To install cross-section catalogs, use the folder symbol. Another dialog opens, where you can select the cross-section catalog file you want to install. Select the file to be installed and click "Open" to confirm. This installs the corresponding cross-section catalog, which you can now use in Allplan.
To install country-specific cross-section catalogs, select the "Ing" folder, which was created when you installed Allplan. You can find it in the Allplan installation path (e.g., c:\Nemetschek\Allplan 201x\New\Ing - more information on the Allplan installation path is provided below in the "Notes" section).
This folder includes the country-specify cross-section catalog files.

To save a custom cross-section catalog, use the disk symbol. Another dialog opens, where you can select any folder to save the cross-section catalogs currently used in Allplan.



Note:

To update cross-section catalogs, you may need administrator privileges. If necessary, log on as an administrator before you start the update.

To use the cross-section catalogs for a specific project only, set the path settings for the cross-section catalogs of this project to project before you install the cross-section catalogs. In Allplan, open the "File" menu and select "Open Project..." Click the corresponding project with the right mouse button. Select "Properties". A dialog box opens. In the "Path settings" area, set the "Bar and mesh cross-section catalogs" to "Project".

To determine the path where Allplan is installed, use the Services application and select Service -> Hotline Tools-> showcfg. The Services application window shows the path of the Allplan installation folder.

The following abbreviations are used for the country-specific cross-section catalogs in the file names (axyzqusr.txt):
aut Austria
bel Belgium
bra Brazil
bul Bulgaria
deu Germany
eng England
fra France
hol Holland
hrv Croatia
ita Italy
kor Korea
pol Poland
rum Romania
rus Russia
slk Slovakia
svn Slovenia
swi Switzerland
tch Czech Republic
ung Hungary
usa USA

Загрузка PDF  FAQ_EN_Updating_cross-section_catalogs_(Allplan_2011...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 01.10.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Internet connection exists on your computer and the settings used for the proxy for the URLs you have set also. You try to activate your license with your product key, but the activation could not be performed. You get the message ' server not found error'. How can the license be activated yet?

Reply:

License activation:

The following description is valid for single user license as also license server licenses.

Try to activate the licenses on the computer/server via the following website online.
This Web site must be launched directly on the computer on which the license should be enabled.


http://lc.codemeter.com/59885/depot/index.php

In the row "Ticket", enter your Product Key and click continue your license will be displayed, click on activate license now.

Note: (only for license server license)
A selection appears asking for the binding of licenses.
Select firm code 6000100 on the right hand side.
'I want my licenses on one computer (CmActLicense). Firm code: 6000100 CmContainer ALLPLAN CM6 (2000)'

Sometimes multiple rows for the same license will be displayed (E.g. license number and a -u behind it) please leave all licenses checked and click on Activate selected licenses now.

The transfer of the license starts now. When activation is finished your license on this page should now appear with status activated.

If the problems with license activation occurred during the installation of ALLPLAN, cancel to exit Setup and restart the installation of ALLPLAN again. Then select in the Setup license configuration use active license now and the installation can continue.

Then open the license setting over services -> utilities-> license settings.
Or license server via License Settings.

Click on the left side on license selection. Now the license is displayed under the computer name.

License return:

This Web site must be launched directly on the computer on which the license should be enabled.


http://lc.codemeter.com/59885/depot/index.php

In the row "Ticket", enter your Product Key and click continue your license will be displayed, click on re-host license now.

Sometimes multiple rows for the same license will be displayed (E.g. license number and a -u behind it) please leave all licenses checked and click on Re-host selected licenses now.

The transfer of the license starts now.

Notes:

  • Sometimes the license is not displayed under license activation, because it has been enabled via the website.
  • If you want to remove the licenses, you must do so via the website again.
Загрузка PDF  FAQ_EN_License_activation_returning_is_still_not_pos...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Последнее изменение: 30.09.2020
3 user(s) found this FAQ helpful

Question:

How can I check out a computer and continue to work as a normal CAD user with my usual settings and permissions?



Answer:

Install the "Microsoft Loopback Adapter" driver.
This driver is necessary so that network services are running on the computer all the time.
Go to Allplan Connect for a detailed description: https://connect.allplan.com/en/faqid/000162ae.html


Sign in as the Allplan administrator to the computer.


Step 1: add the computer to workgroup manager
You must add the computer to the workgroup so that you can store data (data server) on this computer. Do the following:

Create data folders:
Create a folder - for example, “Nemdata” - on the computer and share it (full control).
Create the “Allplan” subfolder in this folder. Create two subfolders - “usr” and “prj” - in the Allplan folder.
In this example: “...\Nemdata\Allplan\prj” and “...\Nemdata\Allplan\usr”

To share a folder for the Allplan file storage

  1. Start File Explorer on the computer that you want to use for file storage and switch to the folder that you want to share (in this example, the “Nemdata” folder).
  2. Right-click the folder that you want to share and select Give access to -> Specific peopleon the shortcut menu.
  3. Select Everyoneand click Share.


Add computer:

  1. Start the Services application as the workgroup administrator.
  2. Click and select Manage computers and projects.
  3. Click the Add any computer to Allplan workgroupicon and select the computer that you want to add.
  4. Select the “Allplan” subfolder under the share and click “OK” to confirm. This computer is now listed under workgroup server.


Note:If you have problems adding the computer to workgroup manager, read the following instructions:
https://connect.allplan.com/en/faqid/20200317162849.html



Step 2: define project owner
A user can only move a project if the user is the owner of this project.
The ownership of a project can only be changed by an Allplan administrator (or the owner of the project).
Allplan -> File -> ProjectPilot ->
Go to the “Projects” node, right-click the required project and click Propertieson the shortcut menu.
Define the owner.


Step 3: move projects
Sign in as the user who wants to check out the computer.
Select the Services application -> Workgroup Manager -> Manage computers and projects.
Click the main server and select the project that you want to move.
Drag the projects one after the other to the computer to be checked out.

Important note: You can take projects with you in several ways.

1. You move the project to the computer.
Move project: Drag the project to the destination computer, or open the shortcut menu of the project and click “Cut”. After this, open the shortcut menu of the destination computer and click “Paste”.
After you have checked in the computer, move the project back to the server so that it is available to all and included in backups again.

2. You copy projects. Click a project, select and hold the Ctrl key and drag the project to the destination computer. Or: Open the shortcut menu of the project and click “Copy”. After this, open the shortcut menu of the destination computer and click “Paste”.

You can continue in two ways: Lock the original project on the server to protect it from changes. Consequently, nobody in the office can work on this project, but it is still on the server. When you check in the computer again, you unlock the project on the server, delete the project and copy your copy back to the server if you have changed the project.
Alternatively, both projects remain active. Consequently, both the project copied and the original on the server can be worked on. In this case, however, you must adjust the data manually when you are back in the office by copying the changed drawing files of the projects by using ProjectPilot.




Step 4: check out the computer
Select the Services application -> Workgroup Manager -> Manage computers and projects.
Click your computer and then click Check outin the lower-right area.
Confirm the message that tells you that there are still user folders on the computer to be checked out.
Enter a comment and click OK. Users in the office see this comment when they try to access a project that is on the computer that is checked out.
Specify the parts of the office standard you want to copy to the computer and click OK to confirm.
The first time you check out the computer, you must copy the office standard once so that the entire STD folder is on this computer. This is no longer necessary when you check out the computer afterward because the contents of the STD folder do not change very often.


Conclusion:

You can now remove the computer from the network and work on your projects when you are out of the office. To make sure that the projects are not changed in the office in the meantime, the projects that are on the computer checked out are locked for the CAD users on the network. These users see the comment you entered when you checked out the computer.



Notes:


Загрузка PDF  FAQ_EN_Workgroup_Manager_checking_out_computer_and_w...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 25.11.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

What can I do if Allplan does not start?


Answer:


Work through the following steps:

Step 1 - run as administrator
Start Allplan with the ‘Run as administrator’ option.
To do this, right-click the Allplan icon and click ‘Run as administrator’.
If Allplan does not start, go to step 2.

Step 2 - cleanup
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanup -> OK
If Allplan does not start, go to step 3.

Step 3 - cleanstd
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanstd: reset CAD defaults -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the settings:
Services application -> Service -> Hotline Tools -> laststd: restore the last settings -> OK -> OK -> Yes -> OK
Go to step 4.

Step 4 - cleanreg
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanreg: reset CAD registry settings -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the registry settings:
Services application -> Service -> Hotline Tools -> lastreg:restore most recent CAD registry settings -> OK -> OK -> Yes -> OK
Go to step 5.

Step 5 (Allplan 2016 and later)
Restart the Wibu service:
Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.

If Allplan does not start, go to step 6.

Step 6 (Allplan 2016 and later)
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.htmlor on the Nemetschek FTP server ftp://nemhotline:ha37jvg8f@ftp.nemetschek.deat download/General/Wibu/CodemeterRuntime.exe

Start the ‘CodeMeterRuntime.exe’ file.
To do this, right-click this file and select
‘Run as administrator’.
Confirm all messages displayed and the defaults by clicking ‘Next’.
CodeMeter Control Center will be installed afterwards.
If Allplan does not start, go to step 7.

Step 7 - contact Technical Support
Send the following information by email to support.de@allplan.com:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
  5. Allplan 2016 and later -> a screenshot of the Wibu Control Center. To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.


We will contact you.

Загрузка PDF  FAQ_EN_Allplan_does_not_start.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 01.10.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Task:

You want to transfer a project with all its settings to a partner office for further editing.

Note:

The following description works only if both partners use the same version of Allplan (Allplan 2018-1 or later).

1. Backing up the project:

Before you back up the project, make sure that “office” or “project” is selected for the path settings of the project.
To do this, open ProjectPilot and select the project: right mouse button -> Properties-> Settings. Here, you can select the path settings.
For exchanging projects with partner offices, we recommend that you switch all project settings to “project”.
This ensures that all pen definitions and line definitions, user-defined fonts, patterns and hatching styles, bar and mesh cross-section catalogs, and layer definitions will be copied to the project and backed up together with the project.

Note:
After the backup, switch the path settings back to “office”. But do not change the paths that already had the “project” setting.

Start Allplan and select the “File” menu -> “New Project, Open Project...”.
Right-click the project that you want to back up and select "Create project backup".
(Allplan 2018: Select “Compress and export project”: )
Select the folder where you want to save the project.

2. Importing the project:

To add a compressed project to the "New Project, Open Project" dialog box

Start Allplan and select the “File” menu -> “New Project, Open Project...”.

  • Drag a compressed project (*.zip) from the desktop or from File Explorer into the "New Project, Open Project" dialog box.
  • Specify the folder and enter a name for the project; then, click OK.
  • Allplan unzips the project, adding it to the project list.


Загрузка PDF  FAQ_EN_Transferring_projects_with_all_settings_to_pa...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Последнее изменение: 12.06.2020
1 user(s) found this FAQ helpful

Question:

What can I do if Allplan no longer starts after I have upgraded and the following messages appear?
Allplan
Stop

...

After this, Quality Reporter displays an error report.



Answer:

Exit Allplan on all workstations and do the following:
Open the Services application and make a note of the path to the 'central file storage folder', which is displayed in the Services application window.
In addition, check whether the workgroup manager line is followed by 'Yes' or 'No'.

Open the central file storage folder in Windows Explorer.

If the workgroup manager line is followed by
'Yes', open the NET subfolder.
'No', open the PRJ subfolder.

Find the 'project.dat' or 'project.Dat.xm' file in the NET or PRJ folder and rename it 'project-old.dat'.

After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> OK -> Restore project management file -> OK
The program creates a new, correct project management file and you can start Allplan again.



Note:

If you come across error messages while doing this, please email the following information to support@allplan.com:

  1. Describe exactly what you did before the error or crash occurred.
  2. The error message itself (as a screenshot).
  3. The log file (trace).
    https://connect.allplan.com/en/faqid/0001a27a.html
  4. A Hotinfo support request with question 01.
    https://connect.allplan.com/en/faqid/20130823123806.html
Загрузка PDF  FAQ_EN_Allplan_does_not_start_after_upgrade_Stop_mes...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012  | Последнее изменение: 30.01.2020
1 user(s) found this FAQ helpful

Task:

You have installed Allplan on several local workstations. Now you want to change the installation so that you can access a common network drive.



Note:

Before you switch to a network installation, it is essential that you back up all the data of all the workstations.
We strongly recommend that you take advantage of the expertise of Nemetschek’s technical support staff. We are happy to help you!



Solution:

The following description shows how to change several workstations where Allplan is installed locally and the project data is also stored locally on each computer to workstations with a common network drive without Workgroup Manager.

1st - getting ready
Choose one of the workstations where you will install all the projects and the office standard (hereinafter referred to as the main workstation).
First, move all the projects to the main workstation.

1.a: copying resources into projects
To make sure that the projects in your office have a uniform appearance, change the path settings for the projects' resources to 'Project'.
Make the following setting for each project:
Allplan -> File menu -> ProjectPilot - Admin -> select the individual projects one after the other -> right mouse button -> Properties -> Settings tab
Set the path settings for 'Pen and line definitions', 'Fonts', 'Patterns, hatching styles, area styles', 'Bar and mesh cross-section catalogs', 'Layer structures, line styles, drawing types' and 'Attributes proposed' from 'Office' to 'Project', if necessary.
The corresponding elements are copied from the office standard directly to the project. This ensures that the project settings stay the same even when you copy the project to the new server with the new office standard.

1.b: same folder name as project name
Open the 'General' tab and select the 'Same folder name as project name' setting if you want to proceed as described in 2b.

1.c: pen color ("Color stands for pen")
The pen color for the "Color stands for pen" setting is a user-specific setting that is not saved in the project but in the user folder (...\Usr).

2.a: backing up projects of the individual workstations and importing them to the main workstation (recommended method):
Back up the individual projects. To do this, open the Services application and select Data Backup -> Create -> Entire folders -> Projects.
You can back up several projects in a single operation.
Before you start, specify the backup folder on the network or on the local hard disk: Services application -> Configuration -> Backup path ->Browse for Folder.

The next step is to import the saved projects to the main workstation.To do this, open theServices application -> Data Backup -> Import -> Projects Before you import the individual projects, you can create new Allplan projects at the main computer. As an alternative, you can also create a new project during the import.

2.b: backing up projects of the individual workstations and importing them to the main workstation (special approach):
This approach should only be used with good reason for exceptional cases as it requires in-depth knowledge of Windows.
With this method, Windows Explorer is used to import the projects to the main workstation.
If some project names exist twice, you need to rename these projects before you back them up.

You can then rename the existing 'project.dat' file in the Prj folder of the main workstation.
Next, select the Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.
The system creates a new project administration file (project.dat), which should list all projects with names.

Now the main workstation contains the latest version of all the projects of the office.

3rd - merging project defaults
Open ProjectPilot at the individual workstations and copy the elements you want to transfer (symbols, smart symbols, lists, schedules, and so on) to the external path. Of course, you can set the external path to a common network folder that can be accessed by all workstations.
Next, open ProjectPilot at the main workstation and copy the contents of the external path to the office standard.

4th - data backup

  • Back up the projects, office standard and user settings at the main workstation:
    You can also copy the ..\prj (projects), ..\std (office standard) and ..\usr (user folder) paths to a backup folder (Nemsic, for example) on the hard disk.
  • In addition, you need to back up the ..\usr\local folder at every stand-alone computer.
  • Export the user interface setting of each user to a file: Allplan -> Tools - > Customize .... -> Export...


5th - uninstalling
Remove Allplan from all workstations.

6th - reinstalling
Before you install the same version again, create and share a folder (Nemdata, for example) on the future data server. Create a subfolder - Allplan - in this folder.

The next step is to reinstall the same version on all the workstations.

Specify the following installation paths:
Program folder:
local (C:\Programs\Nemetschek\Allplan, for example)
Central file storage folder:
Browse -> Network...
Find the sharedNemdata folder and select the Allplan folder.

After this, start installing.

7th - testing the start and restoring the backup
After the installation (check whether Allplan starts), copy the ..\prj and ..\std folders you backed up from the main workstation to the new ...\Nemdata\Allplan server folder.

Next, use Windows Explorer to copy the contents of the former user folder (…\usr\local) of the stand-alone workstation to the new user folder of the computer you just installed.

8th - updating the project administration file
Go to the project.datfile in the ...\Nemdata\Allplan\Prjfolder and rename itproject.alt.After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.

9th - summary
Now all the workstations access a common network drive with the same project pool and office standard.
With this type of installation, only one user can access a project at any one time. If several users are to work on a project at the same time, you need to install Workgroup Manager.

Загрузка PDF  FAQ_EN_Switching_from_single_installation_to_network...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 24.10.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

The licensing service crashes regularly or does not start at all. Afterwards, no license is available. How can I solve this problem?



Answer:

Problems with the licensing service may have various causes.

If this problem occurs with specific clients only, you can find the cause on these clients. If this problem occurs with all clients, you can find the cause on the server.
Check the following points:


1. Virus scanner
The Codemeter Runtime Server service is running both on the client and on the server.

If the service is blocked on the client, this is often caused by the virus scanner.
However, this may also happen on the server.

If communication with the Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So, you need to exclude the "Codemeter" folder from virus scans. You can find this folder in the virus scanner in the following path: C:\Program files (X86)\Codemeteror C:\Programs (x86)\Codemeter. You can find the “Codemeter” folder in the following path:C:\Program files\Codemeteror C:\Programs\Codemeter.

Restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



2. Update the CodeMeter program
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.html

Start the "CodeMeterRuntime.exe" file.
To do this, right-click this file and select
"Run as administrator".
Confirm all messages displayed and the defaults by clicking “Next”.
CodeMeter Control Center will be installed afterwards.



3. Other causes
Open the “C:\Windows\System32\drivers\” or “C:\Windows\SysNative\drivers\” folder and check whether this folder includes a file called "Multikey.sys". You must delete this file.
Before you delete this file, open Windows Device Manager (Control Panel) and check whether a driver called "Virtual USB Multikey X64" is installed.
If this driver is installed, uninstall it
before you delete the "Multikey.sys” file.
If this driver is not installed, delete the "Multikey.sys” file straightaway.

Note:
Sometimes, the system uses the "Multikey.sys” file in the c:\windows\system32\drivers\ folder to emulate a dongle.
This file is blacklisted by Wibu, as it interferes with the Wibu license system.

Sometimes, you can even find the "Virtual USB Multikey x64" device driver when you open Windows Device Manager.
If this driver exists, the "Multikey.sys” file will also exist.



4. Windows
The license server is based on .Net Framework. Allplan uses .NET 4.6. (Allplan 2019 and later will use .NET 4.7). Like any other Windows service, the Codemeter Windows service running on the license server depends on Windows components such as WMI. WMI depends on RPC, and RPC depends on COM distribution.

There may be a bug in Net. Framework of the operating system.
Fixing Net. Framework may solve the problem.

Check Windows Event Viewer and system information for .Net or WMI errors.
.Net may not be installed correctly,
Control Panel -> Administrative Tools -> Event Viewer -> Windows Logs
Check the application, installation and system.
Windows Event Viewer -> Windows Logs -> Application may include an application error in Allplan licensing. This error may be connected with .Net Framework.
Event ID = 1026 This ID indicates an error which you may fix by repairing the installation of .Net Framework.

Fixing Net. Framework may solve the problem.
Go to the Microsoft Support website at https://support.microsoft.com/de-de/help/2698555/microsoft-.net-framework-repair-tool-is-available.
There you can find a repair tool for fixing errors in .Net Framework.


Check Windows Event Viewer and system information for .Net or WMI errors.
.Net may not be installed correctly,
Control Panel -> Administrative Tools -> Event Viewer -> Windows Logs
Check the application, installation and system.




Note:
Do you have a second server? Test the license server on this sever. Install the license server on this server and activate the license there. Use the description at
https://connect.allplan.com/en/faqid/20150618134224.html
Has this solved the problems?

Загрузка PDF  FAQ_EN_Licensing_service_is_not_running.pdf
1 - 10 (16)
https://connect.allplan.com/ uses cookies  -  More information

Accept