Результат поиска

1 - 10 (12)
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Последнее изменение: 30.09.2020
3 user(s) found this FAQ helpful

Question:

How can I check out a computer and continue to work as a normal CAD user with my usual settings and permissions?



Answer:

Install the "Microsoft Loopback Adapter" driver.
This driver is necessary so that network services are running on the computer all the time.
Go to Allplan Connect for a detailed description: https://connect.allplan.com/en/faqid/000162ae.html


Sign in as the Allplan administrator to the computer.


Step 1: add the computer to workgroup manager
You must add the computer to the workgroup so that you can store data (data server) on this computer. Do the following:

Create data folders:
Create a folder - for example, “Nemdata” - on the computer and share it (full control).
Create the “Allplan” subfolder in this folder. Create two subfolders - “usr” and “prj” - in the Allplan folder.
In this example: “...\Nemdata\Allplan\prj” and “...\Nemdata\Allplan\usr”

To share a folder for the Allplan file storage

  1. Start File Explorer on the computer that you want to use for file storage and switch to the folder that you want to share (in this example, the “Nemdata” folder).
  2. Right-click the folder that you want to share and select Give access to -> Specific peopleon the shortcut menu.
  3. Select Everyoneand click Share.


Add computer:

  1. Start the Services application as the workgroup administrator.
  2. Click and select Manage computers and projects.
  3. Click the Add any computer to Allplan workgroupicon and select the computer that you want to add.
  4. Select the “Allplan” subfolder under the share and click “OK” to confirm. This computer is now listed under workgroup server.


Note:If you have problems adding the computer to workgroup manager, read the following instructions:
https://connect.allplan.com/en/faqid/20200317162849.html



Step 2: define project owner
A user can only move a project if the user is the owner of this project.
The ownership of a project can only be changed by an Allplan administrator (or the owner of the project).
Allplan -> File -> ProjectPilot ->
Go to the “Projects” node, right-click the required project and click Propertieson the shortcut menu.
Define the owner.


Step 3: move projects
Sign in as the user who wants to check out the computer.
Select the Services application -> Workgroup Manager -> Manage computers and projects.
Click the main server and select the project that you want to move.
Drag the projects one after the other to the computer to be checked out.

Important note: You can take projects with you in several ways.

1. You move the project to the computer.
Move project: Drag the project to the destination computer, or open the shortcut menu of the project and click “Cut”. After this, open the shortcut menu of the destination computer and click “Paste”.
After you have checked in the computer, move the project back to the server so that it is available to all and included in backups again.

2. You copy projects. Click a project, select and hold the Ctrl key and drag the project to the destination computer. Or: Open the shortcut menu of the project and click “Copy”. After this, open the shortcut menu of the destination computer and click “Paste”.

You can continue in two ways: Lock the original project on the server to protect it from changes. Consequently, nobody in the office can work on this project, but it is still on the server. When you check in the computer again, you unlock the project on the server, delete the project and copy your copy back to the server if you have changed the project.
Alternatively, both projects remain active. Consequently, both the project copied and the original on the server can be worked on. In this case, however, you must adjust the data manually when you are back in the office by copying the changed drawing files of the projects by using ProjectPilot.




Step 4: check out the computer
Select the Services application -> Workgroup Manager -> Manage computers and projects.
Click your computer and then click Check outin the lower-right area.
Confirm the message that tells you that there are still user folders on the computer to be checked out.
Enter a comment and click OK. Users in the office see this comment when they try to access a project that is on the computer that is checked out.
Specify the parts of the office standard you want to copy to the computer and click OK to confirm.
The first time you check out the computer, you must copy the office standard once so that the entire STD folder is on this computer. This is no longer necessary when you check out the computer afterward because the contents of the STD folder do not change very often.


Conclusion:

You can now remove the computer from the network and work on your projects when you are out of the office. To make sure that the projects are not changed in the office in the meantime, the projects that are on the computer checked out are locked for the CAD users on the network. These users see the comment you entered when you checked out the computer.



Notes:


Загрузка PDF  FAQ_EN_Workgroup_Manager_checking_out_computer_and_w...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Последнее изменение: 27.10.2020
1 user(s) found this FAQ helpful

Question:

I can neither check in nor check out the computer.
When I try to check in the computer, the following error message appears: “The registry entries are not correct!” How can I correct this error?


Answer:

There is a hidden file on the server. This file causes the problem, which is probably related to user rights or user account control.

You have to change the settings directly on the server, that is so say, you have to use the folder options to show all hidden folders and files.

1. Open the central file storage folder on the server. There is a subordinate folder called
NET. This folder contains the computer_name.out file. Here, computer_name is the name of the computer that is checked out.
Delete this file.

2. Open the shared folder (for example, C:\Nemdata\Allplan) on the computer that is checked out.
Allplan 2015 and earlier: Delete the Net.ChkOutfolder.
Allplan 2016 and later: Delete the NETfolder.

Now the computer is checked in again. Consequently, you can move projects to this computer
or check it out once more.


Note:

If the computer or the projects are still red, you have to fix the projects.

To fix the projects:
Services application -> Workgroup Manager -> Administer projects and computers

Do the following:

Ctrl + right-click computer
-> can be checked in
Ctrl + right-click project-> can be unlocked

Repeat this step to unlock every project on the computer.
When you have finished, close the dialog box and open it again to update it.
Now everything should be correct.

Загрузка PDF  FAQ_EN_Workgroup_Manager_Problems_when_checking_in_o...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Последнее изменение: 25.11.2019
3 user(s) found this FAQ helpful

Question:

How can I restore a lost building structure or layout structure?



Answer:

To restore a lost or corrupt building structure or layout structure, you can do the following:

  • Close Allplan.
  • Open Windows Explorer, go to the central file storage folder of Allplan and open the "Prj"folder. Open the corresponding project folder and the "BIM" subfolder.

    Note:
    If the "Same folder name as project name" option is not selected for the project, a number is used for the folder name in the "Prj"folder. In this case, open the Services applicationand select the woprohotline tool (Services application -> Service -> Hotline Tools -> wopro). Select the corresponding project by double-clicking its name. An information dialog box shows the folder and file name of the project.
  • You can find an XML file for each structure in the BIM subfolder.


Building structure:
Allplan_BIM_BuildingStructure.xml

Objects derived from building structure:
Allplan_BIM_Views.xml

Plane model:
Allplan_BIM_LevMo_"name of model".xml

Layout structure:
Allplan_BIM_LayoutStructure.xml

  • To restore the building structure from a backup, rename the existing file "Allplan_BIM_BuildingStructure.xml" "Allplan_BIM_BuildingStructure.xml.old", for example.
  • Switch to the "Backup"folder, which you can also find in the"BIM"folder.
  • Select the most recent file that had been created beforethe building structure was deleted, for example, "Allplan_BIM_BuildingStructure.xml.27.5.2008--10-32-21.bak". The characters in bold indicate the date and time of the backup. Copy this file to the "BIM"folder.
  • Rename this file by deleting the characters after ".xml". Now the file name is "Allplan_BIM_BuildingStructure.xml".
  • Restart Allplan. The last version of the building structure is displayed in the "Open on a project-specific basis"dialog box again.




Note:

Using Allplan 2009-2 and later, you can restore the layout structure from a *.bak file straight from the "Open on a project-specific basis: layouts"dialog box.

  • Right-click the topmost structural level in the layout structure (project name) and select Load layout structure favoriteon the shortcut menu.
  • Open the last version of the Allplan_BIM_LayoutStructure.xml file in the backup folder mentioned above.


If the *.bak files are not displayed, please follow the steps described above.

Загрузка PDF  FAQ_EN_Restoring_building_structure_layout_structure...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 01.10.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Does Allplan create backup files (*.bak)?
How can I use these files?



Answer:

Allplan creates backup files when you do the following:

  1. Copy, Move Elements between Documents …
    Allplan creates a backup file of the destination drawing file or layout.
  2. Deleting drawing files and layoutsin the "Open on a project-specific basis" dialog box
    If you have selected "Create backup copies of drawing files", Allplan creates a backup file of the drawing file or layout.
  3. Importing data to drawing files
    If you have selected "Create backup copies of drawing files", Allplan creates a backup file of the drawing file.


Note on points 2 and 3:

To select the "Create backup copies of drawing files" option, click
Tools -> Options -> Desktop environment -> Save/load area (until V2009 Global Options -> Miscellaneous -> Autosave, Backup)->Create backup copies of drawing files.


Restoring:

If need be, you can restore the original drawing file or layout.
Make a note of the drawing file number or layout number and determine the corresponding project folder as follows:
Services application -> Service -> Hotline Tools -> wopro

Open this folder in Windows Explorer.

Rename the corresponding drawing file "tb000001.ndw" "tb000001.ndw.old" or the corresponding layout "pb000001.000" "pb000001.000.old.", for example.
Delete the bak extension from the corresponding bak file.

Example 1:

You have inadvertently copied the wrong elements to drawing file 4711.
1st step: exit the project in Allplan.
2nd step: delete file tb004711.ndw or rename it tb004711.ndw.old.
3rd step: find file tb004711.ndw.bak and rename it tb004711.ndw.

Example 2:

You have inadvertently copied the wrong elements to layout 815.
1st step: exit the project in Allplan.
2nd step: delete file pb000815.000 or rename it pb000815.000.old.
3rd step: find file pb000815.000.bak and rename it pb000815.000.



Note:

These backup files can considerably increase the volume of data to be backed up. So it is a good idea to delete the .bak files you no longer require before you start backing up data. To delete the .bak files, you can select the Services application and click Utilities -> Delete temporary files.

You can also find this information in the help for Allplan. Please refer to the topic "Using bak files".

Загрузка PDF  FAQ_EN_Using_bak_files.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Последнее изменение: 12.11.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Why does ProjectPilot open with the following error message:
"Unable to create ProjectPilot control. Is the registry correct?"



Answer:

The reason for this is usually an "external path" that no longer exists. When you start ProjectPilot,
the program tries to access the "external path", which is stored in the Windows Registry.
If this path no longer exists, you will see the above error message.

To correct this error, please do the following:

  • Services application
  • Service menu
  • Windows Explorer - CAD program folder
  • The path to the "User folder" is displayed in the window of the Services application. Open it in Windows Explorer.
  • Find the "extern.cfg"file in this user folder and delete this file.


Now try to start ProjectPilotagain. If the problem still occurs, please do the following:

Start the services application -> Service -> Windows Explorer -> CAD program folder.
Open the "PRG" folder.
Find the following file: "NemProjectPilot10.exe"
Right-click this file -> select "Run as administrator" on the shortcut menu.
ProjectPilot should now start.

Try to start ProjectPilotstraight from Allplan. If the problem is still not solved, please do the following:

  • Services application
  • Service menu
  • Windows Explorer - CAD program folder
  • The Allplan program folder opens.
  • Rename the "PRG" subfolder "PRG_OLD".
  • Start installing the program from the current Allplan DVD.
  • Select "Update installation".
  • Select "Current license file".
  • Set the setup type to "Minimum".


After installation try to start ProjectPilotagain.

Загрузка PDF  FAQ_EN_Error_message_when_ProjectPilot_starts_Unable...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 24.10.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

The licensing service crashes regularly or does not start at all. Afterwards, no license is available. How can I solve this problem?



Answer:

Problems with the licensing service may have various causes.

If this problem occurs with specific clients only, you can find the cause on these clients. If this problem occurs with all clients, you can find the cause on the server.
Check the following points:


1. Virus scanner
The Codemeter Runtime Server service is running both on the client and on the server.

If the service is blocked on the client, this is often caused by the virus scanner.
However, this may also happen on the server.

If communication with the Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So, you need to exclude the "Codemeter" folder from virus scans. You can find this folder in the virus scanner in the following path: C:\Program files (X86)\Codemeteror C:\Programs (x86)\Codemeter. You can find the “Codemeter” folder in the following path:C:\Program files\Codemeteror C:\Programs\Codemeter.

Restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



2. Update the CodeMeter program
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.html

Start the "CodeMeterRuntime.exe" file.
To do this, right-click this file and select
"Run as administrator".
Confirm all messages displayed and the defaults by clicking “Next”.
CodeMeter Control Center will be installed afterwards.



3. Other causes
Open the “C:\Windows\System32\drivers\” or “C:\Windows\SysNative\drivers\” folder and check whether this folder includes a file called "Multikey.sys". You must delete this file.
Before you delete this file, open Windows Device Manager (Control Panel) and check whether a driver called "Virtual USB Multikey X64" is installed.
If this driver is installed, uninstall it
before you delete the "Multikey.sys” file.
If this driver is not installed, delete the "Multikey.sys” file straightaway.

Note:
Sometimes, the system uses the "Multikey.sys” file in the c:\windows\system32\drivers\ folder to emulate a dongle.
This file is blacklisted by Wibu, as it interferes with the Wibu license system.

Sometimes, you can even find the "Virtual USB Multikey x64" device driver when you open Windows Device Manager.
If this driver exists, the "Multikey.sys” file will also exist.



4. Windows
The license server is based on .Net Framework. Allplan uses .NET 4.6. (Allplan 2019 and later will use .NET 4.7). Like any other Windows service, the Codemeter Windows service running on the license server depends on Windows components such as WMI. WMI depends on RPC, and RPC depends on COM distribution.

There may be a bug in Net. Framework of the operating system.
Fixing Net. Framework may solve the problem.

Check Windows Event Viewer and system information for .Net or WMI errors.
.Net may not be installed correctly,
Control Panel -> Administrative Tools -> Event Viewer -> Windows Logs
Check the application, installation and system.
Windows Event Viewer -> Windows Logs -> Application may include an application error in Allplan licensing. This error may be connected with .Net Framework.
Event ID = 1026 This ID indicates an error which you may fix by repairing the installation of .Net Framework.

Fixing Net. Framework may solve the problem.
Go to the Microsoft Support website at https://support.microsoft.com/de-de/help/2698555/microsoft-.net-framework-repair-tool-is-available.
There you can find a repair tool for fixing errors in .Net Framework.


Check Windows Event Viewer and system information for .Net or WMI errors.
.Net may not be installed correctly,
Control Panel -> Administrative Tools -> Event Viewer -> Windows Logs
Check the application, installation and system.




Note:
Do you have a second server? Test the license server on this sever. Install the license server on this server and activate the license there. Use the description at
https://connect.allplan.com/en/faqid/20150618134224.html
Has this solved the problems?

Загрузка PDF  FAQ_EN_Licensing_service_is_not_running.pdf
Версия:  Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Последнее изменение: 22.02.2018
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I copy bar reinforcement including views and sections created with the tools in the "Associative Views" module if, for example, I want to use slab reinforcement for another floor?
I want to place the copied reinforcement and the views in new, separate drawing files and then adjust the reinforcement, keeping the layout of the copied sections. Only the changes in the copied reinforcement should automatically be added to the sections.


Answer:

First, open ProjectPilot (File -> ProjectPilot) and copy the drawing files with the reinforcement and the drawing file with the associative views and sections to new drawing files. ProjectPilot asks you whether you want to copy the linked drawing files as well. Click No.

If there are views or sections containing only data you do not want to move (for example, only model data), select Create -> Engineering Views, Details -> Associative Views -> Add to Viewand add the data you want to move (for example, reinforcement) to these views or sections. You can remove the data later.


The copied drawing files still reference the original drawing files. The next step is to delete those references.

To do this, open the drawing files you just copied. Select Change -> Engineering Views, Details -> Associative Views -> Manage Reference Drawing Filesand remove the references to the source drawing files.



When you have removed all links to drawing files you do not want to move, select the new drawing files with the views and the reinforcement.


Select all data by pressing <CTRL>+A and move the data as you need.
You can move the data in the X, Y and Z directions in plan or define any spatial displacement in isometric view.

You can then add the associated model data to the views and adjust the reinforcement.

Note:

Once deleted, you cannot restore any references to drawing files. Therefore, make sure you delete the right references. Allplan deletes empty views or sections automatically.

Загрузка PDF  FAQ_EN_Copying_reinforcement_with_associative_views_...
Версия:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Последнее изменение: 14.02.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Allplan starts as a viewer. What can I do?



Answer:

Do the following:

1. The Allplan license folder contains the servcfg.nse file.

Open this folder:
Services application -> Service -> Windows Explorer -> General program data (ETC, LIC) -> License.

Delete the servcfg.nse file from this folder.

2. Install the new, appropriate license, which you can find in the attached file. Save the license to a folder on your computer and install it as follows:
Services application -> Utilities -> License -> Install HARDLOCK License

3. Check that the light indicator of the connected USB dongle (blue or white stick) is on all the time. To test it, you can connect the dongle to a different port.

4. Install the current hardlock driver if the light indicator is off.
You can find detailed instructions here:

https://connect.allplan.com/en/faqid/20131028125253.html

5. Select the Services application -> Utilities -> License -> License settings -> Licenses.
Check if "Allplan FT" is displayed in the white window on the left. If this is so, Allplan has accepted the dongle.

If this is not so, send the logmes.nse file, info.001 file and the new servcfg.nse file (license folder) to support.de@allplan.com


Загрузка PDF  FAQ_EN_First_steps_to_solving_hardlock_license_probl...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Последнее изменение: 25.11.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Whenever I try to create a project, the New Project, Open Projectdialog box does not open.
If I try to open ProjectPilot, the following message appears:Unable to create ProjectPilot control.What can I do?



Answer:

Some important entries are not defined in the Windows Registry.

Close Allplan and do the following:

Services application -> Service -> Windows Explorer -> CAD program folder -> PRG

Find the NemProjectPilot10.exefile and start it as the administrator. To do this, right-click this file -> Run as administrator.
Start Allplan and open ProjectPilot by clicking File -> ProjectPilot. Then create a new project.
After this, open New Project, Open Project. This should work without problems.



Note:

You require administrator privileges to write to the registry.

Загрузка PDF  FAQ_EN_Projects_cannot_be_created_and_ProjectPilot_d...
Версия:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Последнее изменение: 30.11.2017 17:22
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How to install and run NemSLock Server?



Answer:

Before installing, check whether the package you received includes the following items:

  • Temporary licenses for NemSLock Server, e.g. 1234567a_001_psd.nslsrv
  • Temporary licenses for clients, e.g. 1234567a_001_psd_client.nslock



How to install NemSLock Server

  • Start the Setup program for NemSLock Server. You can find the latest Setup program on our FTP server:

ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de/download/Allplan/Lizenzserver/2014/allplan2014-nemslock-lizenz.zip

  • Select one of the temporary license files for NemSLock Server. These licenses are valid for 30 days. However, each license includes only one seat of each configuration purchased. The full number of seats purchased will be available to you as soon as you have installed the registered licenses (see below). If you purchased a configuration for one seat only, you will, of course, receive only one temporary license.
  • When you opt for the “Custom” setup type, you can choose between the following program features:
    Console
    You can use this program to administer NemSLock Server. You can also install the console on more workstations so that you can administer the server from a number of different locations. However, you can only connect one console to the server at any one time.
    Server
    The actual license server.
    Logviewer
    This tool analyzes the log files of NemSLock Server.

By default, Setup installs all these features.
If you have several temporary licenses for NemSLock Server, use the server console to install the remaining licenses after the installation. The procedure is described in the section "How to install licenses".


How to register licenses

  • Open NemSLock 2006 Server Console by clicking the corresponding icon on the desktop or by selecting Start -> All Programs -> NemSLock 2006 Server -> NemSLock 2006 Server Console.
  • Click "Modules" on the left.
  • Select the seat you want to register. If your license includes configurations for several seats, you must send a separate registration request for each seat. You will then receive a registered license file for each seat. You must install each file.
  • Click the "Registration request (register.txt)" button.
  • Click "Edit".
  • You must fill out all fields marked with an asterisk (*). Make sure you enter your email address correctly, because the registered license file will be sent to this address (and not to the address of the person who sent the registration request!). Click OK to confirm.
  • Click "Create registration request". Windows Explorer opens and shows the register.txt file. If this window is closed, you can find this file in the program folder of NemSLock Server. If you installed the program to the path proposed, the path is:
    C:\Program Files (x86)\Nemetschek\NemSLock Server 2006\Programs\License
  • Now you can use all the options provided by Windows Explorer to copy the registration file to a computer with Internet access on the network. Alternatively, you can also use an USB stick. You can then email this file to us.
  • Send the email with the registration request to register@nemetschek.de



How to install licenses

  • Open NemSLock 2006 Server Console.
  • Click "Stop server" on the left.
  • Click "Modules" on the left.
  • Click "Browse" to navigate to the registered license file.
  • Click "Install license file".
  • After this, you can start the server again by clicking "Start server".



How to set up users (optional)

  • predefined user ALLis created automatically. If there is no other user, each user is given the privileges of the user ALL. By default, this user can use all licenses but cannot check out any licenses. By double-clicking the user, you can change the user&apos;s privileges.
  • predefined user ALLallows all users to use licenses. In order to do this, the users must be able to access the server. You do not need to create individual user profiles until you want to assign specific rights to individual users or limit access to selected users. predefined user ALL. If you want to work only with individual users, you should deactivate the predefined user ALL by revoking the user&apos;s right to use licenses.
  • predefined user ALL has administrator privileges unless another user is created and appointed as the administrator. As soon as you have appointed an administrator, ALL no longer has administrator privileges.
  • You can enter users in the “Users.mcf” file. predefined user ALL has administrator privileges again. In addition, each user can once again administer the license server using the console.
  • The administrator user is not a special user. If there are several administrator users, only one administrator user can start the console for this license server at any one time.
  • If you are setting up users without giving administrator privileges to anyone, the program will ask you whether you want to appoint yourself as the administrator.


You can also specify a domain (user authentication for Windows server). However, this is not mandatory. If you do not specify a domain, the program uses the Windows user name for each user.

The program writes the user accounts and the associated access rights as ASCII text to the users.mcf file.

You can find this file in the \Programs folder of the NemSLock Server installation. You cannot rename, delete or move this file. If the program can no longer connect to this file, you must exit NemSLock Server, restart it and enter all users again from scratch. predefined user ALLis retained.

Note:
Experienced administrators can use the PowerShell script NemGenUsers.ps1. This file is in the \Programs folder of the NemSLock Server installation or you can find it as an FAQ in Allplan Connect:

connect.allplan.com/en/faqid/20120907161911.html



How to install and configure clients

  • Use one of the nslock license files you received to install the clients. Do not use the trial license or the license server license. It is irrelevant which of the client licenses you use, as the actual license will come from the license server later.
  • You do not need to register the clients.
  • When switching from Hardlock to NemSLock (server), you need to update the client using a nslock license file.


After having installed the client, you need to switch to the license server:

  • Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager
  • If the license server window is not visible, select "Configure NemSLock Server" at the bottom. Lock this window. All you need to do is click the drawing pin icon.
  • Enter the computer name or IP address of the license server in the empty box. Then click the "Update” icon to the right.
  • Now the user can select one of the seats provided.
  • After having successfully connected to the license server, clear the check boxes for the trial licenses in the area at the top.
  • Click "Close" to complete the configuration. Now you can start Allplan.



Notes:

  • If a user selects several configurations for a seat and starts Allplan, the license server will provide the required licenses; in other words, starting Allplan once might require two licenses. Consequently, fewer licenses are available to other users.
  • 2014-1 and later: If the latest version of License Manager is installed (file version 1. 0. 26. 153 or later, see License Manager- Options- System), you can also select several licenses. If one of the selected licenses is currently being used by someone else, the program will automatically select the next available license.
  • Clients communicate with the server by TCP/IP via port 10977. So you need to configure the firewall accordingly.
  • The license server and the licenses are downward compatible; they can be used in conjunction with older Allplan versions.
Загрузка PDF  FAQ_EN_Installing_and_configuring_NemSLock_Server.pd...