Результат поиска

1 - 10 (33)
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Последнее изменение: 12.11.2020
2 user(s) found this FAQ helpful

Question:

Allplan does not react promptly or seems to hang after I have selected the "Open on a Project-Specific Basis" or "New Project, Open Project" tool.

One of the following virus scanners is running: Trendmicro, McAfee, Kaspersky, Avira, F-Prot and others.
What can I do to solve this problem?



Answer:

Check whether updating the software of the virus scanner solves the problem.

If it doesn't, configure the real time scanner of the virus scanner so that it no longer scans the program folder and data folder of Allplan.

Start the Services application. Make a note of the following paths displayed in the Services application window:

Program folder
General program data
Central file storage folder

Define these folders as exemptions in your virus scanner.


Bear in mind that virus scanners may be installed on the server and the clients (provided you work with a server).
For more information on the virus scanner, contact the manufacturer.

Загрузка PDF  FAQ_EN_Real_time_scanner_blocks_Allplan_data.pdf ...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 03.11.2020
4 user(s) found this FAQ helpful

Question:

  • Why can't I create elements?
  • Why can't I move a drawing?
  • Why are elements not created correctly?
  • Why does the program crash when I import a DXF file from the land registry office?
  • Why is the outline of a circumscribed area not detected correctly?
  • Why can't I calculate shadows?
  • Why are elements not displayed correctly in animation?
  • Why are parts of dimension text missing?
  • Why do the contents of the screen suddenly rotate?
  • Why can't I get a preview when I move or copy elements?
  • Why are areas not calculated correctly?




Finding the reason for these problems:

Check whether an offset is set in the project settings (File -> New Project, Open Project-> select the project and open the shortcut menu -> Properties; Allplan 2009 and earlier: Tools -> Options ->Advanced Draft -> Settings). If there are offset coordinates, clear the check box.

Select Tools -> Measure(->)Coordinates.
Click in the middle of the drawing in plan view.
If there are very large values (for example, x/y/z greater than 5000 m), you have found the reason for these problems.

The system has problems calculating and displaying data with very large coordinates. The more data you have with very large coordinates, the greater this effect.



Solution:

  • Click Tools -> Options... -> Desktop environment -> Generaland select Optimize working with large coordinates(Allplan 2009 and earlier: Tools -> Options -> Global Options -> Miscellaneous tab -> Optimize working with large coordinates). After this you must restart Allplan. Otherwise, this setting has no effect.

This is a user setting you must define separately for each user.

  • Usually, the best solution is to move the data towards the Allplan origin. Use the "Move" tool. When Allplan prompts you to specify the target point ("To point"), select Global point in the dialog line. You can find detailed information in the help for Allplan. Look for the Global pointtopic.



Note:

If the data are still not displayed correctly, do the following:
Exit Allplan -> Services application-> Service -> Hotline Tools-> cleanup -> start Allplan.

Загрузка PDF  FAQ_EN_Large_coordinates.pdf
Версия:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Последнее изменение: 07.08.2019
10 user(s) found this FAQ helpful

Question:

After I updated Windows (8 to 8.1; 8.1 to 10), Allplan only starts as a viewer. What can I do?


Answer:

Windows update corrupts Nemetschek Softlock License Manager.
To fix Allplan, do the following:

You need the latest installation package for your version.
You can download this package from our webdrive

https://webdrive.allplan.com/s/4LrjrymoxESzC6p

You can find the installation packages in the following path:
Allplan/"Version"/Installationspaket/

Copy the zip file to the local computer and unzip the file.
Start the installation and run an update use our temporary license file.

You can download the temporary license from Allplan Connect:
https://connect.allplan.com


After the installation, you can open License Manager again (Services application -> Utilities -> License -> License Manager). Next, install the temporary license (*_psd.nslock): "Install - Install license"
Note: the status of the temporary license is set to "Expired".

Next, create a new registration request.
To generate a registration request, do the following:

Open License Manager (Services application -> Utilities -> License -> License Manager). Select the license entry for your seat and click "Request license".
Follow the instructions displayed on screen. Complete the form. Do not forget to enter your email address.

Check that the Client ID and CD Key are correct.

Send the registration request to: register@nemetschek.de.

Загрузка PDF  FAQ_EN_Fixing_NemSLock_after_Windows_update.pdf ...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 30.09.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Suddenly, one of the following error messages pops up: "This license is no longer available", "CmActLicense runtime system is not installed!" or "NemAll_DataResource20.dll: Start Error 102". After this, Allplan does not start anymore. How can I solve this problem?


Answer:

The local Windows service, which is used by licensing, is not running correctly.

If communication with the local Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So you need to exclude the "Codemeter" folder from virus scans.
You can find this folders in the following path:
C:\Program files (X86)\Codemeter
C:\Program files\Codemeter
C:\ProgramData\CodeMeter

Then restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



Important note:

Follow this link to find out how to configure the virus scanner in conjunction with real-time scanning. Exclude all Allplan folders with their subfolders from virus scans. You can display the paths to the Allplan folders in the Services application window.

https://connect.allplan.com/en/faqid/20091126145752.html


Загрузка PDF  FAQ_EN_Windows_service_for_licensing_is_blocked_by_v...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 24.10.2019
3 user(s) found this FAQ helpful

Question:

Allplan does not start. When you open license selection in the license settings, you can see the following message: "Cannot find a license for running Allplan." Sometimes you might also see one of the following error messages: "This license is no longer available", "CmActLicense runtime system is not installed!" or "NemAll_DataResource20.dll: Start Error 102". Allplan no longer starts after these messages. How to solve this problem?

Answer:

Check the following points:

On the client:

Open the license settings: Services application -> Utilities -> License settings

1. Has the license been blocked on the client?
Check the 'License selection' area to find out whether your license has been blocked. This is indicated by the symbol. If the license is blocked, Allplan cannot use it.
Click this symbol to unblock the license again. If you want, you can select the check box in front of the license to select it as a favorite. Allplan will then prefer this license.
If you do not select any license or if you have selected several favorites, Allplan will automatically use the first free license it finds.


2. Has the server been found?

Select the 'Find license server automatically' option. You should now see the license provided by the server.

Note: In some cases, such as VPN connections, Allplan may not be able to detect a server automatically. In this case, you can enter the server manually.


3. Is the local Windows service, which is used by licensing, running correctly?

If communication with the local Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So you need to exclude the "Codemeter" folder from virus scans. You can find this folder in the following path: C:\Program files (X86)\Codemeter or C:\Programme (x86)\Codemeter

Then restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.


On the license server:

4. Is the 'Start network server' option active?

Start CodeMeter Control Center on the server.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen, enter Codemeter and press ENTER. A dialog box opens. Click WebAdmin at bottom right.

Or
Enter Localhost:22350in the address bar of your browser.

  • Select Settings -> Server -> Access serverin the Network serverarea and click Activate.


Update the license settings on the client. To do this, click Updateor open the dialog box with the license settings again. You should now see the license on the client.


5. Restart the license server service on the server

To start and stop the license server service, you can use CodeMeter Control Center.

  • CodeMeter Control Center -> Action -> Stop CodeMeter Service
  • CodeMeter Control Center -> Action -> Start CodeMeter Service


Update the license settings on the client. To do this, open the dialog box with the license settings again. You should now see the license on the client.


6. Is the virus scanner blocking the Windows service, which is used by licensing, at the server?

If communication with the Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So you need to exclude the "Codemeter" folder from virus scans.
You can find this folder in the following path: C:\Program files (X86)\Codemeter or C:\Programme (x86)\Codemeter
In addition, exclude the C:\Program Files\Allplan GmbHfolder.

Then restart the license server service:
If the service is running, stop it and restart it.


7. Check the firewall

Allplan communicates with the license server via TCP/IP. By default, communication is via port 22350 unless you change the port in CodeMeter WebAdmin. So you need to configure the firewall accordingly.

If a firewall is active on your computer, you must enable port 22350 for TCP and UDP. If the firewall filters in an application-specific manner, you have to enable the CodeMeter.exe license server service. You can find this service in the %Program Files (x86)%\CodeMeter\Runtime\bin Windows folder. Define the CodeMeter.exe service as an exception in the firewall. Some anti-virus programs also include firewall functions. If you are not sure, contact the manufacturer of the anti-virus program.

Загрузка PDF  FAQ_EN_License_server_-_cannot_find_a_license_.pdf ...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 01.10.2020
3 user(s) found this FAQ helpful

Question:

What are the differences between a major release, a service release and a hotfix?



Answer:

Major release

The major release is the first release of a new version.
You can download it from the homepage.

Download:
www.connect.allplan.com -> Download -> Software packages
(requires login details for Allplan Connect)

Name (example):
Allplan 2015


Service release

A service release is a collection of improvements to the program, including all the service releases and hotfixes that have been released until now. In addition to improvements, it may also include new features.
You can also use a service release for a new installation or an upgrade (from a previous version).
You can download it from the homepage.
New customers get it as a DVD. Serviceplus customers get it on request.
In addition, they automatically get information about service releases.

Download:
www.connect.allplan.com -> Download -> Software packages
(requires login details for Allplan Connect)

Name (example):
Allplan 2015-1


Hotfix

A hotfix is an improvement to the program that will automatically be installed by Allplan Update.
The basis for the installation is a specific major release or service release.
Hotfixes are installed one after the other in the correct order, that is to say, first Hotfix 2015-1-1 and then Hotfix 2015-1-2.

Allplan automatically installs available hotfixes when it starts.

You can find more information on hotfixes in the following FAQ:
https://connect.allplan.com/en/faqid/20101203111503.html




Tip:

Install program updates as soon as they are available.

Загрузка PDF  FAQ_EN_Program_updates.pdf
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Последнее изменение: 17.10.2019
5 user(s) found this FAQ helpful

Allplan from version 2011

Parts of Allplan 2011 have been reprogrammed and are completely new. Allplan uses a graphics library, which has been developed especially for CAD programs and visualization tasks. Depending on the data type and application, the display speed of Allplan is much higher than that of earlier versions, and refresh operations are considerably shorter. What's more, you can create hidden line images in real time.
This new technology is not a one-to-one implementation of the software-based solution in the previous version. Instead, a hardware-based approach is used. When it comes to data processing, the graphics card takes on much of the work. The different behavior of these two technologies that may occur in some parts is inherent. Therefore, the resulting display and refresh operations may differ slightly from what you are used to.



General graphics card requirements for Allplan

To fully exploit hardware acceleration capabilities, you require an Open GL 2.0 and DirectX10 (chip-based) compatible graphics card with 512 MB or more memory. Although Windows XP does not support DirectX10, Allplan only requires the chip-based support of the graphics card to manage the graphics library. OpenGL 2.0 is used in 2D and in visualization windows. These changes employ the latest technology in graphic display, so selecting a capable graphics card, and using the proper drivers is essential.

For more information on graphics card specifications, go to:

http://en.wikipedia.org/wiki/Comparison_of_AMD_graphics_processing_units
http://en.wikipedia.org/wiki/Comparison_of_NVIDIA_graphics_processing_units#Quadro)



Professional graphics cards versus Consumer-Level cards

Graphic card manufacturers typically have different product lines targeted for "gamers" and "professional users". While the hardware setup is very similar in case of both cards, there are key differences in their firmware and driver. "Consumer-Level cards" (such as Nvidia GeForce and AMD/ATI Radeon) are optimized for 3D games and technologically designed for DirectX10, as speed is more important than image quality.
Typically a 3D model in a game contains a low number of polygons with textures applied to them, while in CAD applications polygon count is high, and the image quality of wireframe models or shaded models is more important than navigation speed. Also, professional cards' memory usage is optimized for using multiple application windows, while in gaming this is not relevant.
Another key difference between the two product lines is the way they are delivered and supported. Professional cards (such as Nvidia Quadro and AMD/ATI FireGL/PRO) are built according to the video chip manufacturer's references, so you can always be sure that the driver delivered by the video chip manufacturer (such as Nvidia or AMD/ATI) fits your card.
The manufacturers of Consumer-Level cards (such as ASUS, Sapphire, Gigabyte, PNY and so on) may diverge from the chip manufacturer's references, so their drivers may not be compatible with the chip manufacturer's reference driver. Also, the product life cycle and driver release cycles are much shorter in case of gaming cards, usually 6 months up to 1 year at most and a 1-year warranty period maximum.

Example: comparison of graphics cards

Consumer-Level cards
Professional graphics cards / workstation
Products
Radeon
FireMV
FireGL/Pro
Mobility FireGL/Pro
Markets
  • Private customers: desktop systems and notebook systems
  • Corporate desktop systems
  • Corporate CAD and DCC desktop systems and notebook systems
Applications
  • Home/office publishing, productivity, multimedia, games, Internet
  • Finance, clearance, logistics, airport information displays
  • CAD/CAM/CAE, AEC, DCC, GIS, MI, visual simulation, scientific research/imaging
Certification
  • WHQL certification
  • Industrial applications
  • WHQL certification
  • Professional 3D applications
  • WHQL certification
Operating
systems
  • Windows 98SE / Me / XP
  • Windows Vista,
    Windows 7
  • Windows XP, XP64,Vista, Vista 64, Windows 7, Windows 7 64
  • Linux
Drivers
  • Optimized for DirectX
  • Basic Open GL
  • Optimized and designed for DirectX
  • Optimized and advanced Open GL
Life cycle
  • Available for 1 year on average
  • Available for 2-3 years on average
Support
  • Basic, private customers
  • Direct access to dedicated support by trained technicians
Warranty
  • 1 year
  • 3 years with replacementof components




Professional graphics cards versus Consumer-Level cards

Professional graphics cards differ considerably from "Consumer-Level cards" for private users with regard to specific market segments with special requirements:

  • Extensive application tests and certifications with CAD providers
  • Optimized and advanced support for API as well as further developments
  • Longer product life cycles and availability
  • Direct product support
  • Longer warranty period


Nemetschek Allplan GmbH cooperates with Nvidia und AMD to test graphics card drivers for the Nvidia FX Quadro/ Quadro and AMD/ATI FireGL/ Fire Pro series. These product lines are tested, certified and recommended for Allplan by Nemetschek Allplan Systems GmbH.

For more information on certified graphics cards, go to:

www.nemetschek.eu/info/grafikkarten
www.nemetschek.eu/info/graphiccards

There are four different categories and areas:

Graphics cardApplicationQuality testsStatus
Gaming graphics cards3D GamesTested / not testedNot recommended
    
Professional graphics cards3D basisCertified and recommendedEnd of life
    
Professional graphics cards3D performanceCertified and recommendedEnd of life
    
Professional graphics cards3D high performanceCertified and recommendedEnd of life




Recommended graphics cards for laptops (Windows)

For reasons detailed above, we cannot recommend any specific card and driver combination for laptops. However, there are professional graphics cards available for high-end laptops such as NVidia FX Quadro & Quadro NVidia "M" or AMD/ATI FireGL & FirePro "Mobility".
These graphics cards are just as good as their desktop counterparts.
Laptops with Consumer-Level cards have been tested only briefly and cannot be recommended. We have had bad experience with on-board Intel graphics cards.



Graphics cards drivers for Apple Macintosh

Since Macs come with a default graphics card (on-board or gaming), and the drivers are bundled with system updates, we cannot recommend a specific card.
Graphics cards for MacOsX 10.6 (Leopard) or later and Boot Camp support Open GL 2.0 and DirectX10. Currently, there is only one series that is equipped with a professional graphics card: Mac Pro with NVidia FX4800 for Mac.


Notes for Allplan and Macintosh:

  • There is no provision for a direct installation under Macintosh.
  • Access to Windows must be straight from the Boot Camp installation.
  • For performance reasons, Parallels Desktop cannot be used in conjunction with Nemetschek Allplan.


We kindly ask you to understand that Nemetschek Allplan cannot provide support for Boot Camp installations.



Installing graphics cards drivers (Windows)

Graphics cards only work properly if they have a hardware provider supplied driver (not system built-in driver) installed correctly. It may happen that remnants of a previous installation interfere with the current driver installation. If you experience display issues with the drivers listed below, please "clean-install" the driver again. "Clean-install" means removing all previous driver files before installing a new driver. Unfortunately, a simple uninstall may not efficiently remove all components of a driver. There are tools that can do it, like ATI's cat uninstaller or third-party tools like driver cleaner or driver cleaner pro 1.5.



Graphics card drivers for laptops (Windows)

In most cases, graphic card drivers for laptops are supplied by the laptop manufacturer, and graphic card provider supplied drivers will not install on laptops. This makes it practically impossible for us to test laptop graphics cards. If you are experiencing display issues with your laptop, and your supplier does not offer you a driver update, you might try - at your own risk - to tweak a desktop driver to work on your laptop. Note that this is obviously not encouraged by your laptop supplier.

Загрузка PDF  FAQ_EN_Graphics_cards_for_Allplan.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 12.11.2020
1 user(s) found this FAQ helpful

Question:

Why is Allplan running so slow?


Answer:

Check the following points:

1. Current version
Make sure you work with the current Allplan version.

  • Do the following or ask your system administrator to do this:
    Open Allplan and click the ‘?’ icon in the upper right-hand corner. Click ‘Update Allplan’.
    Select 'Find now'. If Allplan finds updates or hotfixes, download the installation packages.
  • Deactivate the virus scanner while your are installing updates or hotfixes. This might require administrator privileges. Contact your system administrator if you have problems.
  • Right-click the Allplan icon on the desktop. A shortcut menu opens.
    Select ‘Run as administrator’ and click ‘Yes’ to confirm the following message.
    As a result, Windows security settings do not block the installation.



2. System requirements:
Check the hardware and software required for your Allplan computer.

2.a)Download and run the system test.
Check the notes.
https://www.allplan.com/de/system/systemvoraussetzungen/

2.b)Check the Allplan system requirements:
https://www.allplan.com/de/system/systemvoraussetzungen/

2.c)You can find information about graphics cards at
https://connect.allplan.com/de/support/grafikkarten.html

2.d)You can find server operating systems you can use for the central file storage of Allplan at
https://connect.allplan.com/en/faqid/20140924094923.html


3. Hotline tools:
Start the Services application, open the ‘Service’ menu and select ‘Hotline Tools’. To save your settings, select the following tools.

- savestd: Saves user defaults.
- savereg: Saves CAD registry settings.

Start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:

- cleanup: Initializes the display.
- cleanstd: Resets CAD defaults.
- cleanreg: Resets CAD registry settings.

Check whether this has solved the problems.
If this is not so, restore the settings you just saved. To do this, start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:
- reststd: Restores saved user defaults.
- restreg: Restores CAD registry settings.


4. Color scheme selected in Allplan:
Start Allplan, open the ‘View’ menu, point to ‘Toolbars’ and select ‘Customize User Interface’. Open the ‘Customize’ tab and set ‘Color scheme and icon design’ to ‘Windows’.


5. Check the availability of all projects that are not online (if you use Workgroup Manager):
Start Allplan, open the ‘File’ menu and select ‘New Project, Open Project’. Deactivate ‘Check availability of all offline projects’.


6. Virus scanner
Check whether an anti-virus program is running in the background of the computer or server.
If so, reduce protection to "programs only".

Scanning "all files" can take a long time, considerably slowing down your computer when you switch between projects or exit the program.
You can exclude the Allplan installation folders from real-time scanning.When you start the Services application, you can see a list of the folders to be excluded.
You can find more information at
https://connect.allplan.com/en/faqid/20091126145752.html
Changes in the settings of the virus scanner only come into effect when you re-start the computer.


7. Aero desktop effects
Deactivate the Aero desktop effects of Windows.
To do this, open the Control Panel, select ‘Ease of Access’ and go to the ‘Make things on the screen easier to see’ area.
Select the ‘Turn off all unnecessary animations (when possible)’ option.


8. Name resolution on the network
If Allplan takes several minutes to start, name resolution on the network may not work.
To check this, do the following:
Right-click the Windows Start Button, select ‘Run’, type in ‘cmd’, click OK, type in ‘Nslookup’ and press ENTER.
Go to the line following the > character, type in the name of the Allplan data server and press ENTER.
The reply starts with the name and address of the server providing name resolution.
You can find the name and address of the Allplan data server in the second group.
If problems occur, contact your network administrator and ask him or her to configure name resolution correctly.


9. Speed of Allplan projects
Check whether some Allplan projects are slower than other Allplan projects.
Start with the empty project and check whether it is slow too.
After this, select any other Allplan project.

If it is only the current project that is slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


10. Network: checking out Allplan using Workgroup Manager
If you use Allplan with Workgroup Manager, you can check whether the problems are caused by the network. To do this, check out the workstation with the project in question and use the project on the local Allplan workstation.
You can find detailed information on checking out an Allplan workstation using Workgroup Manager in the
Services application. Open the ‘Help’ and select ‘Workgroup Manager’.

After you have checked out the workstation, Allplan no longer accesses the central file storage of the server.
If this has solved the problems, they are caused by the network. In this case, the network must be checked in detail.
Contact your network administrator and ask him or her to do this.

If the project is still slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


11. Log files and system information files
If all the points above do not solve the problems, technical support requires more system information about the computer running Allplan.

  • So, we would be grateful if you could send us a support request (Allplan Hotinfo with Allplan logging).
    To create a support request, start the Services application, open the ‘Service’ menu and select ‘Create support request (Hotinfo)’.
    Several dialog boxes open. Select ‘Technical Support Allplan’ and ‘Enquiry with Allplan logging’. Enter all the data required. Finally, click ‘Finish’.
    Another dialog box opens, prompting you to start Allplan. Click the ‘Start Allplan’ button.
    Allplan starts, logging all processes.
    Try to reproduce the problem as exactly as possible.
    Exit Allplan as soon as possible, reducing the data in the log file to a minimum.
    Then click ‘Next’ to generate the support request with the log file.
    You can find more information about Hotinfo at
    https://connect.allplan.com/en/faqid/20140528094911.html
  • To analyze the Windows system environment, we would ask you to send us the logs created by Windows Event Viewer of your computer.
    To start Windows Event Viewer, right-click the Windows Start Button, select ‘Run’ and type in ‘eventvwr.msc’.
    You can also type in ‘Event Viewer’ in the search box of Windows. This displays the link file to the Windows event logs.
    Using Event Viewer, create *.evtx files for the application log and the system log in the ‘Windows Logs’ area and for the ‘Administrative Events’ log in the ‘Custom Views’ area.


Please send us the files.

Загрузка PDF  FAQ_EN_Allplan_is_running_slow.pdf
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Последнее изменение: 25.11.2019
4 user(s) found this FAQ helpful

Note:

You can help the technical support team to process your request by generating a support request with the Hotinfo program and sending it to us.

The generated support request will help to avoid unnecessary questions and delays, as it automatically contains all necessary information pertinent to the problem in question.


Procedure:

The Hotinfo program is installed along with Allplan; you can start it over the following ways:
1. Start -> All Programs -> Nemetschek -> Allplan [version number] -> Hotinfo [version number].
2. Allplan -> ? -> Generate support request (Hotinfo)
3. Allmenu/Services -> Service -> Create Support request (Hotinfo)


Select the team with whom you wish to communicate:
Choose the relevant entry, for example, Technical Support Allplan. The email address of the selected team is entered automatically.

Select the areas on which you have questions:
Please select the question that is pertinent to your support request.
You only need to select question 2 when Allplan support is requesting it from you.

01. General inquiry
02. Inquiry with Allplan logging

Note on question 02:
If you have selected question "02. Inquiry with Allplan logging", you can start Allplan straight form the Hotinfo after the questions.
This will generate and attach a log (trace).
Start Allplan by clicking on the button “Start Allplan”
Carefully reproduce the problem – for example, perform the steps that lead to the failure.
Then click "Next" to generate the support request with the trace.
You can click the "Take screenshot" button at any time while Allplan is running in logging mode. This way, you can quickly and easily save any error messages that may be displayed.

Enter your contact address:
Please enter your name, telephone number and email address
so that the technical support team can contact you.

Please describe the problem:
Describe the problem in detail (for example, include the exact wording of error messages).

Select the files you want to attach to the email:
You can include additional files with important information such as damaged drawing files, NID files or other files.

Note:
These files are only attached to the email when you send the Hotinfo by clicking “Finish” -> Option “Start email program…" or send it to us over File -> Send Message...".
See note further down.

Create the screenshots you want to attach to the email:
You can use the "New screenshot" button to take screenshots of the entire screen and send them as a file attachment to the Hotinfo.

Note:
These files are only attached to the email when you send the Hotinfo by clicking “Finish” -> Option “Start email program…" or send it to us over File -> Send Message...".
See note further down

Finish
Here you have the possibility over the pre-selected option "Start Email program..." to start your email program with the created Hotinfo, the generated files as a file attachment and the correct destination address. You only need to press 'Send'.

Over option "Open Hotinfo file to save it..."you can open the support request, save, and send as an email attachment to support.de (please no spam) @ (please no spam) allplan.com, if no e-mail program is installed locally.
In this case, make sure to attach in addition to the support request all additional files also. Attach the "attached files" and "generated screenshots" independently as attachment to your email.

Загрузка PDF  FAQ_EN_Generating_a_support_request_using_Hotinfo.pd...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Последнее изменение: 31.08.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I fix Allplan program data?


Answer:

You can fix Allplan program data by renaming the program folders and installing an update.
Due to the new names, Allplan cannot find the resources during the update. Consequently, it creates new resources.

To fix Allplan program data, do the following:

You need the latest installation package for your version.
You can download this package from Allplan Connect (www.connect.allplan.com) or from our FTP server.

Accessing the FTP server:
Enter the following address in Windows Explorer (do not use Internet Explorer!):
ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de

You can find the installation packages in the following path:
/download/Allplan/"version"/CD/
Copy the zip file to the local computer and unzip the file.

  • Open the Services application of the Allplan version you want to fix.
  • Select Service -> Windows Explorer -> CAD program folder.
  • Rename the "PRG" folder "PRG_OLD". If Windows Explorer tells you that a file is still in use, restart the computer and try again.
  • Start the *.exe file of the installation package you just unzipped.
  • Select "Update installation".
  • When Setup prompts you for the license, select "Current license file" or "Use active license".
  • Select "Minimum" for the Setup type.



Allplan gets new program resources during installation.
As soon as the installation is complete, you can test how Allplan behaves.


Note:

If you are not sure, give these instructions to your system administrator.
Keep in mind that you install the version of the installation package you downloaded. This means that you may have to reinstall any subsequent hotfixes.

Загрузка PDF  FAQ_EN_Fixing_Allplan.pdf