My computer does not have Internet access, but I would like to activate the license with the Product Key. What can I do?


Information:

The easiest way to activate and return Allplan licenses is to do this online. In other words, the computer has Internet access. However, you can also activate Allplan on a computer without Internet access (offline licensing). Offline licensing is particularly useful if some Allplan computers in your office do not have Internet access and do not use a license server either.

If the computer without Internet access and the computer with Internet access are neither close to each other (for example, the computer in the office hasInternet access, but the computer at home does not haveInternet access) nor connected with each other (for example, using LAN), offline activation is not very suitable, as you have to access both the computer with Internet access and the computer without Internet access.

Requirements for activating a license offline:

  • You have a valid Product Key.
  • You have installed Allplan on the computer without Internet access (for example, as a viewer).
  • You have another computer with Internet access.


Important: Activating a license offline involves two steps. In addition, you need to upload a receipt file so that you can return the license offline later.

There are the following basic steps:

  • Creating and uploading the license request file
  • Downloading and importing the license update file
  • Creating and uploading the receipt file


The online computer uses the following web page:
http://lc.codemeter.com/59885/depot/index.php


Note:

As both the license file and the receipt file are saved with the name of the container number by default, it may happen that you mix up these two files. Therefore we strongly recommend that you use meaningful names for the files. For example, the name could include the name of the computer and the Product Key or the words “license” and “receipt”.
This is particularly important if you want to activate several computers offline.


Answer:

A: Activating licenses offline

To activate licenses, use CodeMeter Control Center.

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. An an alternative, go to the Windows search box and type Codemeter.

You can find the container numbers in the ‘License’ area.
If you have a stand-alone license, the name of this container is Allplan GmbH and its number is 327XXXXXXX.

Select this container and click Activatelicense on the right. Select
Create license request. Create a *.WibuCmRaC file for your container.

Take this file to a computer that is online.
Go to the following web page:
http://lc.codemeter.com/59885/depot/index.php

Enter your Product Keyin the “Ticket” line and click Next. You can now see your license.
Click Activate license.

You can see your license and all available updates, which should be selected. Click Offline License Transferat the bottom on the right.

You can now upload the *.WibuCmRaC file (Browse....) by clicking Upload license request now. This creates your license, which you can download by clicking Download license update file now. Install this license on your computer.

To do this, go to CodeMeter Control Center and click File-> Importlicense.


You can see the activated license in the Services application -> Utilities -> License settingsand you can now use this license for Allplan.


Finally, upload the receipt file.
To do this, open CodeMeter Control Centeragain and select the new Allplan GmbH license with the number 128-XXXXXXX.

Then click License update -> Next -> Create receipt.
Create the receipt file for this container.
Upload this receipt file using the web page.

Take this file to the computer that is online. Click Nexton the web page.
If you have already closed the web page, use the link given above and enter your Product Key once again. Then select Continue with license transfer.
Select the receipt file and click Upload receipt now.
Click OKto confirm. This completes license activation.




B: Returning licenses offline

You can return licenses in the same way:
Start CodeMeter Control Center and select the container with the license (Allplan GmbH with the number 128-XXXXXXX). Then click License update -> Next -> Create license request.
Here, too, create a *.WibuCmRaC file for your container.

Take this file to a computer that is online.
Here, too, go to the following web page:
http://lc.codemeter.com/59885/depot/index.php

Enter your Product Keyin the “Ticket” line and click Next. You can now see your license.
Click Move license.
Click Offline License Transferat the bottom on the right.
You can now upload the *.WibuCmRaC file (Browse....) by clicking Upload request now.
Then click Download license update file now. Download the file and import it. To do this, go to CodeMeter Control Centerand click File -> Importlicense.

Then create a receipt by clicking License update -> Next -> Create receipt.
Upload this receipt file using the web page.
To do this, click Nexton the web page.
If you have already closed the web page, use the link given above and enter your Product Key once again. Then select Continue with license transfer.
Select the receipt file and click Upload receipt now.
Click OKto confirm. This completes license activation.

The license is now available again and can be used on another computer.

Загрузка PDF  FAQ_EN_Activating_license_offline_(without_Internet_...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 12.11.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I change the cache path for Allplan Share?

Note:

You do this at your own risk.
We strongly recommend that you clarify all issues in advance.
Always copy a file before you change it.
Before you change registry entries, back up the registry key that you want to modify. To do this, export the key by selecting File - Export in the Registry Editor.

Answer:

Allplan Share temporarily saves the project data in the path of the local file storage, which you defined when you installed Allplan.
You can see the path of the local file storage folder in the Services application.
If this folder is centrally on a server for all Allplan workstations:
To avoid replication conflicts that might occur when several users work on the same project data, you must change the path settings for each user so that this folder is locally on the user’s computer running Allplan.

Before you start, close Allplan, making sure that you do not lose any data.

  1. Go to a local drive (C or D) of the computer running Allplan and create the new "Local data” folder with the "Allplan” subfolder (for example, C:\Local data\Allplan).
  2. Start the Windows Registry Editor as the administrator (start - run - regedit).
  3. Go to the left column of Registry Editor and open the following key: HKEY_LOCAL_MACHINE\SOFTWARE\Nemetschek\Allplan\2018.0\InstallRoot. If Allplan 2019 or a newer Allplan version is installed, “2019.0“ or the newer version replaces “2018.0” in the path.
  4. Go to the right column of Registry Editor and double-click theLocalDataDrivekey. Specify the drive that you selected for local file storage (for example, C:). Then click OK to confirm the change. This applies the change.
  5. Then, go to the right column of Registry Editor again and double-click theLocalDataPathkey. Specify the path that you defined for local file storage (for example,\Local Data\Allplan). Then click OK to confirm the change. This applies the change. The result should look like this:
  6. Close the Registry Editor. Allplan now uses the new path for the cache of Allplan Share.
  7. Start Allplan and select the Allplan Share project to load the necessary project data into the new cache.



Загрузка PDF  FAQ_EN_Adjusting_the_local_file_storage_folder_for_A...
Версия:  Allplan BCM 2014 / Allplan BCM 2013 / Allplan BCM 2012 / Allplan BCM 2011 / Allplan BCM 2009  | Последнее изменение: 23.10.2020
1 user(s) found this FAQ helpful

Question:

How can I install a license for the following programs?

  • Allplan BCM Building Costs (formerly Allright)
  • Allplan BCM Construction Cost
  • Allplan BCM Quantities
  • BOS (BuildingOfficeSystem)




Answer:

1) You want to install the program for the first time or upgrade it. -> Option 1)
2) You have already installed or upgraded the program; now all that remains is to install a current license. --> Option 2)

License files
If we sent you a ZIP file or you downloaded one from the Serviceplus portal, save this file to your computer.
Extract the data in a folder of your choice.

The license contains the following files:

  • Allright.lzd
  • Setup.exe
  • Npsrequ.dat (optional)
  • 111111.knr


Option 1)

  • Install the program.
  • Setup prompts you to specify the license. Specify the folder where you saved the license data mentioned above.
  • Continue to install the program. After the installation, you can start the program without having to install another license.


Option 2)
To install the latest license, you do not need to install the program from scratch. Just install the license data.

Do the following:

  • CloseallAllplan BCM applications that are running on your computer and on any other computer on the network.
  • Start Windows Explorer.
  • Open the folder with the data in Windows Explorer.
  • Double-click the Setup.exefile.
  • The license will be installed automatically.
  • If you purchased the Tenderer module, you must install the license on each computer. Otherwise, it is enough if you install the license on any computer just once.



Note:

If you have problems, send us the exact wording of the error message and the license data (all the files of the ZIP file).
You can send the data by email to support.de@allplan.com.

Загрузка PDF  FAQ_EN_License_installing_license.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Последнее изменение: 30.09.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

I installed Allplan with Workgroup Manager on a new computer for the first time. When I start Allplan, I get the following message: The user profile "DOMAIN\user name" was not found. Temporarily, the profile of local will be used.
Therefore, I cannot access any project. What can I do?



Answer:

You have logged in to the computer with a new Windows user who does not yet exist in Workgroup Manager administration of Allplan.
You need to add this new user to Workgroup Manager. To do this, log in as the administrator to the computer or use a different computer where a user has administrator privileges for Workgroup Manager.

Services application -> Workgroup Manager -> Administrate users -> right-click -> Create user

For the "user name", you can enter any Allplan user name, which can be up to 8 characters long.
For the "Windows user name", you must enter the name the user uses for login.
Important: If the user uses a domain for login, you must add it to the "Windows user name", for example, DOMAIN\user.


There is one Allplan administrator and any number of normal Allplan users.
A Windows user with any login name becomes an Allplan administrator if you go to "User group" and
select "Administrator"on the dropdown menu. Using this approach, you can also assign administration privileges to existing users.


You must enter the email address and the password only if the user is notpart of the workgroup but needs access to online projects (Workgroup Online).


Important: Click "Apply" and then "OK" to close the dialog box and the user overview respectively.



Note:

After you have created the user as an Allplan user, do not forget to assign the relevant projects to this user. Otherwise, this user is not allowed to edit the projects.
To find out how to
make several projects available to users: https://connect.allplan.com/en/faqid/0001cbd2.html

Загрузка PDF  FAQ_EN_The_user_profile_was_not_found_Temporarily_th...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Последнее изменение: 27.10.2020
1 user(s) found this FAQ helpful

Question:

I can neither check in nor check out the computer.
When I try to check in the computer, the following error message appears: “The registry entries are not correct!” How can I correct this error?


Answer:

There is a hidden file on the server. This file causes the problem, which is probably related to user rights or user account control.

You have to change the settings directly on the server, that is so say, you have to use the folder options to show all hidden folders and files.

1. Open the central file storage folder on the server. There is a subordinate folder called
NET. This folder contains the computer_name.out file. Here, computer_name is the name of the computer that is checked out.
Delete this file.

2. Open the shared folder (for example, C:\Nemdata\Allplan) on the computer that is checked out.
Allplan 2015 and earlier: Delete the Net.ChkOutfolder.
Allplan 2016 and later: Delete the NETfolder.

Now the computer is checked in again. Consequently, you can move projects to this computer
or check it out once more.


Note:

If the computer or the projects are still red, you have to fix the projects.

To fix the projects:
Services application -> Workgroup Manager -> Administer projects and computers

Do the following:

Ctrl + right-click computer
-> can be checked in
Ctrl + right-click project-> can be unlocked

Repeat this step to unlock every project on the computer.
When you have finished, close the dialog box and open it again to update it.
Now everything should be correct.

Загрузка PDF  FAQ_EN_Workgroup_Manager_Problems_when_checking_in_o...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Последнее изменение: 25.11.2019
3 user(s) found this FAQ helpful

Question:

How can I restore a lost building structure or layout structure?



Answer:

To restore a lost or corrupt building structure or layout structure, you can do the following:

  • Close Allplan.
  • Open Windows Explorer, go to the central file storage folder of Allplan and open the "Prj"folder. Open the corresponding project folder and the "BIM" subfolder.

    Note:
    If the "Same folder name as project name" option is not selected for the project, a number is used for the folder name in the "Prj"folder. In this case, open the Services applicationand select the woprohotline tool (Services application -> Service -> Hotline Tools -> wopro). Select the corresponding project by double-clicking its name. An information dialog box shows the folder and file name of the project.
  • You can find an XML file for each structure in the BIM subfolder.


Building structure:
Allplan_BIM_BuildingStructure.xml

Objects derived from building structure:
Allplan_BIM_Views.xml

Plane model:
Allplan_BIM_LevMo_"name of model".xml

Layout structure:
Allplan_BIM_LayoutStructure.xml

  • To restore the building structure from a backup, rename the existing file "Allplan_BIM_BuildingStructure.xml" "Allplan_BIM_BuildingStructure.xml.old", for example.
  • Switch to the "Backup"folder, which you can also find in the"BIM"folder.
  • Select the most recent file that had been created beforethe building structure was deleted, for example, "Allplan_BIM_BuildingStructure.xml.27.5.2008--10-32-21.bak". The characters in bold indicate the date and time of the backup. Copy this file to the "BIM"folder.
  • Rename this file by deleting the characters after ".xml". Now the file name is "Allplan_BIM_BuildingStructure.xml".
  • Restart Allplan. The last version of the building structure is displayed in the "Open on a project-specific basis"dialog box again.




Note:

Using Allplan 2009-2 and later, you can restore the layout structure from a *.bak file straight from the "Open on a project-specific basis: layouts"dialog box.

  • Right-click the topmost structural level in the layout structure (project name) and select Load layout structure favoriteon the shortcut menu.
  • Open the last version of the Allplan_BIM_LayoutStructure.xml file in the backup folder mentioned above.


If the *.bak files are not displayed, please follow the steps described above.

Загрузка PDF  FAQ_EN_Restoring_building_structure_layout_structure...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Последнее изменение: 01.10.2020
4 user(s) found this FAQ helpful

Question:

How can I install a hotfix?


Answer:

Allplan automatically downloads hotfixes and installs them the next time you start Allplan.
To define settings in Allplan, open the ? menu and select Update Allplan.

Click the Find now button to find updates and install them the next time you start Allplan.


Notes:

1. Downloading hotfixes manually

You can also download hotfixes manually.
Open our homepage
(http://www.connect.allplan.com) and select
Downloads.

The current hotfix and previous hotfixes are available for download.
Before you can download data, you must log in to Allplan Connect


2. Installing hotfixes downloaded manually

You can install the hotfixes downloaded by double-clicking the file. Make sure both Allplan and the Services application are closed.
Hotfixes are installed one after the other in the correct order. In other words, you must download and install Hotfix 2014-1-1 before you can install Hotfix 2014-1-2.


3. Working with Workgroup Manager

If you work with Workgroup Manager and another user has already downloaded the hotfix, you can see the following message:

There are currently no updates available.

In tis case, the hotfix is in the Downloadfolder on the server. In Allplan select ?-> Update Allplan. Choose one of the following options to install the hotfix the next time you start Allplan:

  • Install updates automatically-> the next time you start Allplan, the program will install the hotfix without asking you again.
  • Download updates, install manually (recommended)-> the next time you start Allplan, a dialog box opens and you can decide whether you want to install the hotfix.


The default setting is
'Download updates, install manually (recommended)'.

Загрузка PDF  FAQ_EN_Installing_hotfixes.pdf
Версия:  Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 13.05.2020
1 user(s) found this FAQ helpful

Question:

The windows for options and the window for IFC import and export are closed immediately when opened. How can this issue be solved?



Answer:


1. HP computer

If you are using an HP (Hewlett-Packard) computer, please take these steps. Otherwise proceed to number 2.

Check whether the security software "HP ProtectTools" is installed on this computer. If yes, then uninstall "HP ProtectTools". This software suite consists of several progams. In most cases, these programs are:

  • HP ProtectTools Device Access Manager
  • Embedded Security for HP
  • Face Recognition for HP ProtectTools
  • File Sanitizer For HP ProtectTools
  • Privacy Manager for HP ProtectTools
  • Theft Recovery
  • Drive Encryption for HP ProtectTools
  • HP ProtectTools Security Manager



It is possible that more or less HP software than the listed is installed. When you uninstall the "HP ProtectTools Security Manager", no other dependent software should be listed during uninstallation.

If there is dependent software listed during uninstallation, please uninstall these programs first. As the last step, "HP ProtectTools Security Manager" should be uninstalled.

An example message, listing dependent software which is still installed:




Important notice: Please restart the computer to complete uninstalling the software.




2. Dell computer

If you are using a Dell computer, please take these steps. Otherwise contact the Allplan support.

Check whether the security software "Dell Data Protection" is installed on this computer. If yes, then uninstall "Dell Data Protection". This software suite consists of several progams. In most cases, these programs are:

  • Dell Data Protection | Security Tools Authentication
  • Dell Data Protection | Security Tools


It is possible that more or less Dell software than the listed is installed. When you uninstall the "Dell Data Protection", no other dependent software should be listed during uninstallation.

If there is dependent software listed during uninstallation, please uninstall these programs first. As the last step, "Dell Data Protection" should be uninstalled.

An example message, listing dependent software which is still installed:




Important notice: Please restart the computer to complete uninstalling the software.




Notes:

HP ProtectTools Security Suite was developed by McAfee in cooperation with HP. It is pre-installed on most HP business notebooks and on some HP desktop computers.

HP ProtectTools are using Full Volume Encryption (FVE) by McAfee Safeboot, which changes the Win32 API behaviour. This causes problems in Allplan.

Also Dell is using similar mechanisms for the Dell Data Protection Suite. They have the same influence on Allplan.

Please note that these programs in either case have negative effects on stability and functionality of Allplan, even if you might not notice it (example: working options and IFC windows in different Allplan version).


Загрузка PDF  FAQ_EN_Options_window_IFC_window_closed_immediately_...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Последнее изменение: 30.09.2020
1 user(s) found this FAQ helpful

Task:

Several users require Allplan administrator privileges in an installation with Workgroup Manager.



Note:

There are normal users and Allplan administrators in Allplan installations with Workgroup Manager.
Allplan administrators are:

  • Windows users with any login name who are granted administrative rights in the Workgroup Manager administration.

In other words, a Windows user with Windows administrator privileges does not necessarily have to be an Allplan administrator at the same time.

We do not recommend that several users work with Allplan administrator privileges at the same time, making it difficult to manage and protect the office standard, that is, the global settings. See solution 1.

However, if it is essential that several users are Allplan administrators, see solution 2.


Solution 1:

There is one Allplan administrator and normal Allplan users.

As the owner of a project has advanced rights in this project, you can define a user as the owner in a project and set the required resources to 'project'.
File -> New Project, Open Project... -> right-click the project you need -> Properties ... -> Path settings
Set the required resources to project.
You can also make these settings when you create a project or in ProjectPilot.

In addition to the Allplan administrator, another user (the owner of the project) can now define settings in the project.

Notes:

  • There are two standards for the definitions set to project: office and project.
  • It is only the Allplan administrator who can make changes in the office standard.



Solution 2:

Windows users with any login name are set up as Allplan administrators.


First, set up the Windows user as an Allplan user.
Services application -> Workgroup Manager -> Administrate users -> right-click->Create user

For the "user name", you can enter any Allplan user name, which can be up to 8 characters long.
For the "Windows user name", you must enter the name the user uses for login.
Important: If the user uses a domain for login, you must add it to the "Windows user name", for example, DOMAIN\user.

Grant the administration privilege to the "user group":
select "Administrator"on the dropdown menu. Using this approach, you can also assign the administration privilege to existing users.

Important: Click "Apply" and then "OK" to close the dialog box and the user overview, respectively.

Загрузка PDF  FAQ_EN_Several_users_with_Allplan_administrator_priv...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Последнее изменение: 24.10.2019
1 user(s) found this FAQ helpful

Question:

How can I give individual users the right to see and select specific seats on the license server? And how can I deny users this right?
Sometimes, it may be necessary that a specific user does not see the seat with, for example, the terrain option so that this user cannot use this seat inadvertently.


Answer:

Using WebAdmin, you can give users rights for specific seats on the license server.
Please note the following points:

1. Before you start, check that at least CodeMeter Version 6.50 is installed on the license server.
Start CodeMeter Control Centeron the server.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen. Enter Codemeter and press ENTER. Select Help -> About to see which version of CodeMeter is installed. If the version displayed is older than version 6.50, you must install the latest version of CodeMeter Control Center. Go to the following website
and download the CodeMeter User Runtime for Windowsprogram.

https://www.wibu.com/de/anwendersoftware.html

2. Open WebAdmin. Start CodeMeter Control Centeron the server again.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen, enter Codemeter and press ENTER. A dialog box opens. Click WebAdminat bottom right.

Or
Enter Localhost:22350in the address bar of your browser.

3. Go to "Configuration -> Server -> License Access Permissions".
Select Mode: Advanced.

4. Go to "Advanced Mode Configuration -> Specific access rules -> Add Firm Code"and select "6000100 - Allplan GmbH". Click Add. "Specific access rules"now inlcude "6000100 - Allplan GmbH".





5. Click "Add Product Code"to select the seat for which you want to define access rights. However, this is only possible if the "Distinction based on Product Item Text" check box is selected.
The "Note" section below in this FAQ lists the abbreviations given at the end of each seat. These abbreviations represent the license contents.
Select the required seat and click "Add" again. Repeat these steps to assign more seats.





6. After having defined the product code, you can now assign an access rule.
By default, all users are allowedto access this seat.
Select the product code you just defined and click "Add new access rule".
Click "User" and enter the required user.
When you click in the field next to "User", you can see all available users with their domain names.
Select the user or enter the user manually. For example, enter DOMAINNAME\SSample and select the right you want to assign to this user by clicking "Allow" or "Deny".

If the default setting is "Allow", you can thus deny users access to the license. If the default setting is "Deny", you can thus allow users to access the license again.
You can add more rules. When you have configured all rules, click "Apply" to apply the changes.

7. You need to restart CodeMeter Service so that the changes take effect.
To do this, select CodeMeter Control Center -> Process -> Stop CodeMeterServiceand then click Restart CodeMeter Service.Before you restart the service, make sure all users have closed Allplan.


Information:

Client access can be defined by one of the following parameters: computer name, IPv4 subnet, user name or group name.
Enter the required parameter in the corresponding field. If you use an active directory, the program auto-completes entries in the "User" and "Group" fields.


Here comes a practical example:

Think about which setting is most useful to you. For example, you have two seats: seat 01 with 7 architecture licenses and seat 02 with 1 architecture license and 1 terrain license. Only two specific users should be able to use seat 02. If you want to deny all other users access to seat 02, you need to add seat 02 to specific access rules and define a rule for this seat 02. First, set the default setting to "Deny". Then, add these two users and select or "Allow" for these users. As a result, all other users can only see seat 01 and these two users can see seats 01 and 02.

However, if you want that these two users can only see seat 02, you need to add both seats to specific access rules and define a second rule for seat 01. Add these two users to this second role and select Deny for these two users. The default setting, which applies to all the other users, is still Allow. As a result, all other users can see seat 01 and these two users can only see seat 02.


Note:

The following abbreviations are used:

T Terrain
B Bamtec
W Workgroup
K Key Plan
M Bridge Modeler
L Cadastral plans for conduits
S Language option
V Visualization
A Architecture option
E Engineering option

Here are some examples:

Architecture:
"Allplan Architecture 2017”

Architecture + Terrain
"Allplan Architecture 2017 T"

Architecture + Bridge Modeler
"Allplan Architecture 2017 M"

Architecture + Terrain + Bridge Modeler
"Allplan Architecture 2017 TM"

Загрузка PDF  FAQ_EN_License_server_-_assigning_access_rights_for_...