Версия:  Allplan 2021  | Последнее изменение: 06.10.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Information:

This document provides additional information on installing Allplan 2021.

Data backup/archiving:

We strongly recommend that you perform a complete data backup and archive this data before you upgrade to Allplan 2021!


Installation Instructions:


Detailed installation instructions can be found in the following places:

- If you have downloaded and unpacked Allplan 2021, you will find the file install.chm in the folder C:\Users\Public\Documents\Allplan 2021\HelpFiles\English


Please read these before installing Allplan 2021.

System requirements Allplan 2021

https://connect.allplan.com/de/faqid/20200930085615.html

Licenses when upgrading to Allplan 2021

https://connect.allplan.com/en/faqid/20200821110044.html


Extract from the installation instructions (see above)

If you want to switch from Allplan 2018/2019/2020 to Allplan 2021, you have three basic installation options.

1. New installation

Allplan 2021 is installed in a new folder. Any existing installations of Allplan (2020 or older) are not affected. No data and settings are transferred to the new installation.

The following options are available for transferring data later:

Uninstall Allplan 2021 and then upgrade Allplan 2018/2019/2020.
Integrating the data by hand (administrator knowledge required).

2. New installation with data copy from version

Allplan 2021 is installed in a new folder. Any existing installations of Allplan (2020 or older) are not affected. The office standard (\std), projects (\prj) and user data (\usr) can be automatically copied from an existing version 2018/2019/2020 to the new installation folder.
In this way, you can create a duplicate dataset if necessary: all projects, standards and resources can be used in both Allplan 2021 and 2018/2019/2020. This allows you to test the transition to the new version in real life, while the existing Allplan installation remains fully functional.
Note, however, that this method of working should avoid parallel processing of data in both installations, as the subsequent merging is time-consuming.

2a. Continuation of new installation with data copy from version

This option is available if a new installation with data copy has already been performed on another computer accessing the same data server and therefore the data has already been transferred.

3. Upgrade with data transfer from version 2018/2019/2020

Allplan 2021 is installed in an existing folder. The existing installation of Allplan 2018/2019/2020 is converted to Allplan 2021 and all important settings are transferred (see also Limitations for Data Transfer). Allplan 2018/2019/2020 is then no longer available.
Any existing installations older than Allplan 2018 are not affected.


Network Installations:

For network installations (shared 'central file storage folder'), only one main release version can be used - all workstations must be brought to Allplan 2021. Before starting the installation, make sure that all workstations have upgrade authorization. A mixed installation of different main versions is not technically approved. Complications that may arise are not covered by the maintenance contracts.

During the upgrade, no workstation may be running any version 2020, 2019 or 2018.

In case of an installation with Workgroupmanager all workstations must be checked in during the upgrade.




Data Conversion:

Data from older Allplan versions must be converted to version 2021. This happens automatically for projects opened in Allplan 2021. For instructions on how to convert all projects at once, click here:

https://connect.allplan.com/de/faqid/20090408124904.html

Загрузка PDF  FAQ_EN_Hotletter_2021.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 30.09.2020
7 user(s) found this FAQ helpful

Question:

I have renewed my license or purchased an additional option or additional licenses for a license server license. How can I update the license?


Answer:

If you have purchased an additional option, such as terrain, or additional licenses for a license server license, you have to update your license to include this new option.

To update a license

License for a stand-alone workstation:

  • Open the 'License settings' dialog box: Services application -> Utilities -> License settings
  • Click License activationon the left. Then click the license you want to update.
  • The 'Update license' button is no longer grayed out.
  • Click Update license.


On the license server:

  • Start the License Settingsprogram on the server.
  • Click License activationon the left. Then click the license you want to update.
  • The 'Update license' button is no longer grayed out.
  • Click Update license.


Note:
Check the version of the license server. You can find detailed information on the version (Build-ID) at bottom left in the License Settings program.
Make sure the version of the license server you use is at least 1.614.x.x. If you cannot see the Build-ID, you work with an older license server.
If this is so, update the license server. Download the software for the license server from Allplan Connect or from our FTP server:

ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de/download/Allplan/Lizenzserver/2017/DoWn-License_Server_Setup.zip

Загрузка PDF  FAQ_EN_Updating_license.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 30.09.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I make several projects available to users when Workgroup Manager is installed?



Answer:

You can make several projects available to a user or define a user as the project owner of several projects.

Do the following:

First, log in as the Allplan administrator.
If necessary, set up an Allplan user for the new Windows user: Services application -> Workgroup Manager -> Configuration -> Add a user
(Allplan 2014 and later:Services application -> Workgroup Manager ->Administer users)

Start Allplan and then ProjectPilot by clicking
File -> ProjectPilot

Open the Projects folder in the area on the left.
You can see all the projects in the Contents of "Projects" area on the right.

a. Making several projects available to users:
In the area on the right, select the projects to which you want to add users or from which you want to remove users (CTRL or SHIFT key or use a selection rectangle).

Click one of the selected projects with the mouse button. On the shortcut menu, click
Add / remove authorized users...
The Add / Remove Authorized Usersdialog box opens.

Select the users you want to add to or remove from the selected projects.
Note:
The user list displayed only helps you select users. It does not list all the authorized users currently assigned to projects.

Click Addor Remove.
This adds or removes the selected users to or from the selected projects. Whether users you have already added to a project are added again is irrelevant. The same applies if you remove users you have never added to a project.

b. Defining a project owner for several projects
In the area on the right, select the projects for which you want to define the owner (CTRL or SHIFT key).

Click one of the selected projects with the mouse button. On the shortcut menu, click
Change project owner...
The Define Owner dialog box opens.

Select the user you want to define as the owner of the selected projects.
Note: The user list displayed helps you select users. You can define only one user as the owner.

Click OK.

c. Defining a project owner for a project or making a project available to several users(also applies to earlier versions):
In ProjectPilot in the area on the right, click the relevant project with the right mouse button. On the shortcut menu, click Properties.
The Properties for <project name>dialog box opens. Switch to the Security tab and define the owner and the authorized users.



Note:

You can add or remove project users or define the project owner only if the projects in question are in the current Allplan format.

Загрузка PDF  FAQ_EN_Making_several_projects_available_to_users.pd...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012  | Последнее изменение: 30.01.2020
1 user(s) found this FAQ helpful

Task:

You have installed Allplan on several local workstations. Now you want to change the installation so that you can access a common network drive.



Note:

Before you switch to a network installation, it is essential that you back up all the data of all the workstations.
We strongly recommend that you take advantage of the expertise of Nemetschek’s technical support staff. We are happy to help you!



Solution:

The following description shows how to change several workstations where Allplan is installed locally and the project data is also stored locally on each computer to workstations with a common network drive without Workgroup Manager.

1st - getting ready
Choose one of the workstations where you will install all the projects and the office standard (hereinafter referred to as the main workstation).
First, move all the projects to the main workstation.

1.a: copying resources into projects
To make sure that the projects in your office have a uniform appearance, change the path settings for the projects&apos; resources to &apos;Project&apos;.
Make the following setting for each project:
Allplan -> File menu -> ProjectPilot - Admin -> select the individual projects one after the other -> right mouse button -> Properties -> Settings tab
Set the path settings for &apos;Pen and line definitions&apos;, &apos;Fonts&apos;, &apos;Patterns, hatching styles, area styles&apos;, &apos;Bar and mesh cross-section catalogs&apos;, &apos;Layer structures, line styles, drawing types&apos; and &apos;Attributes proposed&apos; from &apos;Office&apos; to &apos;Project&apos;, if necessary.
The corresponding elements are copied from the office standard directly to the project. This ensures that the project settings stay the same even when you copy the project to the new server with the new office standard.

1.b: same folder name as project name
Open the &apos;General&apos; tab and select the &apos;Same folder name as project name&apos; setting if you want to proceed as described in 2b.

1.c: pen color ("Color stands for pen")
The pen color for the "Color stands for pen" setting is a user-specific setting that is not saved in the project but in the user folder (...\Usr).

2.a: backing up projects of the individual workstations and importing them to the main workstation (recommended method):
Back up the individual projects. To do this, open the Services application and select Data Backup -> Create -> Entire folders -> Projects.
You can back up several projects in a single operation.
Before you start, specify the backup folder on the network or on the local hard disk: Services application -> Configuration -> Backup path ->Browse for Folder.

The next step is to import the saved projects to the main workstation.To do this, open theServices application -> Data Backup -> Import -> Projects Before you import the individual projects, you can create new Allplan projects at the main computer. As an alternative, you can also create a new project during the import.

2.b: backing up projects of the individual workstations and importing them to the main workstation (special approach):
This approach should only be used with good reason for exceptional cases as it requires in-depth knowledge of Windows.
With this method, Windows Explorer is used to import the projects to the main workstation.
If some project names exist twice, you need to rename these projects before you back them up.

You can then rename the existing &apos;project.dat&apos; file in the Prj folder of the main workstation.
Next, select the Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.
The system creates a new project administration file (project.dat), which should list all projects with names.

Now the main workstation contains the latest version of all the projects of the office.

3rd - merging project defaults
Open ProjectPilot at the individual workstations and copy the elements you want to transfer (symbols, smart symbols, lists, schedules, and so on) to the external path. Of course, you can set the external path to a common network folder that can be accessed by all workstations.
Next, open ProjectPilot at the main workstation and copy the contents of the external path to the office standard.

4th - data backup

  • Back up the projects, office standard and user settings at the main workstation:
    You can also copy the ..\prj (projects), ..\std (office standard) and ..\usr (user folder) paths to a backup folder (Nemsic, for example) on the hard disk.
  • In addition, you need to back up the ..\usr\local folder at every stand-alone computer.
  • Export the user interface setting of each user to a file: Allplan -> Tools - > Customize .... -> Export...


5th - uninstalling
Remove Allplan from all workstations.

6th - reinstalling
Before you install the same version again, create and share a folder (Nemdata, for example) on the future data server. Create a subfolder - Allplan - in this folder.

The next step is to reinstall the same version on all the workstations.

Specify the following installation paths:
Program folder:
local (C:\Programs\Nemetschek\Allplan, for example)
Central file storage folder:
Browse -> Network...
Find the sharedNemdata folder and select the Allplan folder.

After this, start installing.

7th - testing the start and restoring the backup
After the installation (check whether Allplan starts), copy the ..\prj and ..\std folders you backed up from the main workstation to the new ...\Nemdata\Allplan server folder.

Next, use Windows Explorer to copy the contents of the former user folder (…\usr\local) of the stand-alone workstation to the new user folder of the computer you just installed.

8th - updating the project administration file
Go to the project.datfile in the ...\Nemdata\Allplan\Prjfolder and rename itproject.alt.After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.

9th - summary
Now all the workstations access a common network drive with the same project pool and office standard.
With this type of installation, only one user can access a project at any one time. If several users are to work on a project at the same time, you need to install Workgroup Manager.

Загрузка PDF  FAQ_EN_Switching_from_single_installation_to_network...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 30.09.2020
1 user(s) found this FAQ helpful

What are the advantages of the new licensing method?

  • Better protection; easier to use (for example, when you want to transfer the license to a different computer).


What is the Product Key?

  • The Product Key is a unique, 26-digit character string. You can use it to activate a license for Allplan.


How do I get my Product Key(s)?


How do I transfer my activated license to a different computer or to a new computer?

  • Before you can transfer the license to a different computer, you first have to return the license on the computer where you originally activated it. Then you can enter the Product Key on a different computer, activating the license there. For more information, go to https://connect.allplan.com/en/faqid/20150618131629.html


How do install Allplan or activate my license on a computer without Internet access?

  • The easiest way to activate and return Allplan licenses is to do this online. In other words, the computer has Internet access. However, you can also activate Allplan on a computer without Internet access. For more information, go to https://connect.allplan.com/en/faqid/20150618131413.html


How can I update a license (for example, after I have purchased an additional option)?


Can I still use hardlocks?

  • No, you can&apos;t. Allplan 2016 no longer supports hardlocks.


How do I install Allplan as a trial version?

  • Download Allplan 2016 from Allplan Connect. You will receive the Product Key for the trial version by email.



Загрузка PDF  FAQ_EN_General_information_on_the_new_licensing_meth...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 24.10.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

The licensing service crashes regularly or does not start at all. Afterwards, no license is available. How can I solve this problem?



Answer:

Problems with the licensing service may have various causes.

If this problem occurs with specific clients only, you can find the cause on these clients. If this problem occurs with all clients, you can find the cause on the server.
Check the following points:


1. Virus scanner
The Codemeter Runtime Server service is running both on the client and on the server.

If the service is blocked on the client, this is often caused by the virus scanner.
However, this may also happen on the server.

If communication with the Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So, you need to exclude the "Codemeter" folder from virus scans. You can find this folder in the virus scanner in the following path: C:\Program files (X86)\Codemeteror C:\Programs (x86)\Codemeter. You can find the “Codemeter” folder in the following path:C:\Program files\Codemeteror C:\Programs\Codemeter.

Restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



2. Update the CodeMeter program
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.html

Start the "CodeMeterRuntime.exe" file.
To do this, right-click this file and select
"Run as administrator".
Confirm all messages displayed and the defaults by clicking “Next”.
CodeMeter Control Center will be installed afterwards.



3. Other causes
Open the “C:\Windows\System32\drivers\” or “C:\Windows\SysNative\drivers\” folder and check whether this folder includes a file called "Multikey.sys". You must delete this file.
Before you delete this file, open Windows Device Manager (Control Panel) and check whether a driver called "Virtual USB Multikey X64" is installed.
If this driver is installed, uninstall it
before you delete the "Multikey.sys” file.
If this driver is not installed, delete the "Multikey.sys” file straightaway.

Note:
Sometimes, the system uses the "Multikey.sys” file in the c:\windows\system32\drivers\ folder to emulate a dongle.
This file is blacklisted by Wibu, as it interferes with the Wibu license system.

Sometimes, you can even find the "Virtual USB Multikey x64" device driver when you open Windows Device Manager.
If this driver exists, the "Multikey.sys” file will also exist.



4. Windows
The license server is based on .Net Framework. Allplan uses .NET 4.6. (Allplan 2019 and later will use .NET 4.7). Like any other Windows service, the Codemeter Windows service running on the license server depends on Windows components such as WMI. WMI depends on RPC, and RPC depends on COM distribution.

There may be a bug in Net. Framework of the operating system.
Fixing Net. Framework may solve the problem.

Check Windows Event Viewer and system information for .Net or WMI errors.
.Net may not be installed correctly,
Control Panel -> Administrative Tools -> Event Viewer -> Windows Logs
Check the application, installation and system.
Windows Event Viewer -> Windows Logs -> Application may include an application error in Allplan licensing. This error may be connected with .Net Framework.
Event ID = 1026 This ID indicates an error which you may fix by repairing the installation of .Net Framework.

Fixing Net. Framework may solve the problem.
Go to the Microsoft Support website at https://support.microsoft.com/de-de/help/2698555/microsoft-.net-framework-repair-tool-is-available.
There you can find a repair tool for fixing errors in .Net Framework.


Check Windows Event Viewer and system information for .Net or WMI errors.
.Net may not be installed correctly,
Control Panel -> Administrative Tools -> Event Viewer -> Windows Logs
Check the application, installation and system.




Note:
Do you have a second server? Test the license server on this sever. Install the license server on this server and activate the license there. Use the description at
https://connect.allplan.com/en/faqid/20150618134224.html
Has this solved the problems?

Загрузка PDF  FAQ_EN_Licensing_service_is_not_running.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 30.09.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

You want to include a computer in the Allmenu via Workgroupmanager, but no network environment is displayed and no result appears when you enter the computer name in Search. How can the computer still be included?



Answer:

All computers included in the Workgroupmanager are stored in the data.cfg on the server in the central file storage request.
The Allmenu window shows the exact path of the "central file storage folder".

e.g. \\SERVER\data\Allplan
Go via Windows Explorer to the central file storage folder in the NET folder and open the file data.cfg (e.g. with the editor)

The content of the file looks like this
SERVER \data\Allplan

(So far no computer has been included and therefore there are no further entries in this example)

Here you can enter the new path of the computer to be recorded
Simply enter the computer name, spacebar, shared folder, subfolder as a new line.
Enter only your simple host name here, not the FQDN name (first name only, without periods and other additions)

Please make sure that all entries are flush with each other. Please do not remove the space bars in existing entries and also insert a space bar after the host name when entering, these are important.

So it looks like this

SERVER \data\Allplan
COMPUTERNAME \Nemdata\Allplan

Save the file.

As a result, the computers in the workgroup are displayed in the Allmenu/Services application under Workgroupmanager - > Administer projects and computers and can now be checked out.

Загрузка PDF  FAQ_EN_Workgroupmanager_Adding_the_computer_is_not_p...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Последнее изменение: 16.10.2020
1 user(s) found this FAQ helpful

Question:

How can I install additional Allplan workstations on an existing network (with or without Workgroup Manager)?



Answer:

Before you install the additional workstations, find out the path to the central file storage folder on a computer where Allplan has already been installed. Open the Services application on this computer. The Services application window shows the path to the central file storage folder.

Enter this path when Setup prompts you to specify the central file storage folder.
Select "Minimum" for the Setup type.



Notes:

  • Make sure the version you are installing is the same as the one installed on the other workstations.
  • In addition, make sure all workstations are running either with Workgroup Manager or without Workgroup Manager. To find out whether Workgroup Manager is installed or not, open the Services application and check the menus: if you can see the Workgroup Manager menu, Workgroup Manager is installed.
  • Installing additional workstations does not affect the data (projects, ...) in the central file storage folder.
  • If you add new users to a new Allplan workstation, do not forget to add them to the Workgroup Manager, too.
  • Version 2014 and earlier: if one of the computers also serves as the Allplan server, you cannot use the approach described above to find out the path to the central file storage folder.
    In this case, you will see the path to a local folder instead of the central file storage folder.
    Use a different computer to find out the path to the central file storage folder.
Загрузка PDF  FAQ_EN_Installing_Allplan_on_a_network_later.pdf ...
Версия:  Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 13.05.2020
1 user(s) found this FAQ helpful

Question:

The windows for options and the window for IFC import and export are closed immediately when opened. How can this issue be solved?



Answer:


1. HP computer

If you are using an HP (Hewlett-Packard) computer, please take these steps. Otherwise proceed to number 2.

Check whether the security software "HP ProtectTools" is installed on this computer. If yes, then uninstall "HP ProtectTools". This software suite consists of several progams. In most cases, these programs are:

  • HP ProtectTools Device Access Manager
  • Embedded Security for HP
  • Face Recognition for HP ProtectTools
  • File Sanitizer For HP ProtectTools
  • Privacy Manager for HP ProtectTools
  • Theft Recovery
  • Drive Encryption for HP ProtectTools
  • HP ProtectTools Security Manager



It is possible that more or less HP software than the listed is installed. When you uninstall the "HP ProtectTools Security Manager", no other dependent software should be listed during uninstallation.

If there is dependent software listed during uninstallation, please uninstall these programs first. As the last step, "HP ProtectTools Security Manager" should be uninstalled.

An example message, listing dependent software which is still installed:




Important notice: Please restart the computer to complete uninstalling the software.




2. Dell computer

If you are using a Dell computer, please take these steps. Otherwise contact the Allplan support.

Check whether the security software "Dell Data Protection" is installed on this computer. If yes, then uninstall "Dell Data Protection". This software suite consists of several progams. In most cases, these programs are:

  • Dell Data Protection | Security Tools Authentication
  • Dell Data Protection | Security Tools


It is possible that more or less Dell software than the listed is installed. When you uninstall the "Dell Data Protection", no other dependent software should be listed during uninstallation.

If there is dependent software listed during uninstallation, please uninstall these programs first. As the last step, "Dell Data Protection" should be uninstalled.

An example message, listing dependent software which is still installed:




Important notice: Please restart the computer to complete uninstalling the software.




Notes:

HP ProtectTools Security Suite was developed by McAfee in cooperation with HP. It is pre-installed on most HP business notebooks and on some HP desktop computers.

HP ProtectTools are using Full Volume Encryption (FVE) by McAfee Safeboot, which changes the Win32 API behaviour. This causes problems in Allplan.

Also Dell is using similar mechanisms for the Dell Data Protection Suite. They have the same influence on Allplan.

Please note that these programs in either case have negative effects on stability and functionality of Allplan, even if you might not notice it (example: working options and IFC windows in different Allplan version).


Загрузка PDF  FAQ_EN_Options_window_IFC_window_closed_immediately_...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Последнее изменение: 15.04.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Can I "automate" the installation of Allplan?


Answer:

You can install Allplan 2017 in silent mode. This installation mode is fully automatic; you do not need to enter anything. Silent installation is particularly useful if you want to install Allplan 2017 with the same settings on a large number of workstations on a network.

Requirements for installing in silent mode:

Pay attention to the different licensing types!

Licensing for stand-alone workstations:
Make sure you have not yet activated a license on the computer where you want to record silent installation. Use the Viewer option for recording.

After having installed all computers in silent mode, you must use the Product Key to activate the license locally on each computer.
To activate the license after installation:

  • Open the &apos;License settings&apos; dialog box: Services application -> Utilities -> License settings
  • Click License activationon the left.
  • Enter your Product Key.
  • Click Activate license.


Using a license server:

  • The clients take the licenses from a license server.
  • The license server is installed.
  • The license of the license server is activated.

For more information on the license server, go to https://connect.allplan.com/en/faqid/20150618084450.html
Use the Use active licenseoption for recording.

Setup writes the license settings to the %AppData%\Nemetschek\Lic3.ini file.You must distribute this file to all computers.


Some more tips:

  • Before you start installing, unzip the Allplan installation package (for example, using the 7_Zip program). Make sure this package is in a folder that can be accessed by all clients you want to install.
  • Start the command prompt for running the setup program always as a local administrator. To do this, open the shortcut menu and select "Run as administrator". Make sure you always start the command prompt from the correct folder.
  • Setup will automatically install any Microsoft components required by Allplan such as Microsoft .NET-Framework or Microsoft Report Viewer without prompting you to confirm.




Preparing to install in silent mode

To record and run silent installation, you need the installation files of Allplan 2017.
Installing in silent mode involves three steps:

Creating the log file for installing in silent mode

Start by installing Allplan 2017 with the /r option on a typical workstation. During installation, Setup automatically writes all entries to a log file named setup.iss. You can then use this file to install the program on the other workstations.

Installing in silent mode

Next, install Allplan 2017 with the /s option on all other workstations. Installation is based on the setup.iss log file you created in the first step.

Checking the installation

Finally, you should check the setup.log file, which was created automatically during setup, to see whether everything was installed correctly.

Note: When installing in silent mode, Setup usually uses the same setup.iss file to install the program on all workstations. However, you can edit some settings of the setup.iss file if you want to adjust paths. You can find more information in the help; see Adjusting the setup.iss filehttp://help.allplan.com/Allplan/2017-0/1031/Allplan/index.htm#331.htm


To install Allplan in silent mode, do the following:

Install .NET 4.6
Silent setup requires you to install .NET 4.6 in advance. The reason for this is that you have to reboot the computer after installation of .NET 4.6. This reboot would interrupt silent installation.


After you have downloaded the installation files, you must unzip these files before you can use them to install in silent mode.

  • Unzip the zip file downloaded. This results in an .exe file (for example, Allplan 2017-0-5-cad.exe).
  • Then unzip this .exe file using an appropriate program (for example, 7_Zip) and save the resulting file to any folder. You can now use the command prompt to start Setup.exe for recording.



1. Sample installation:
Start by creating a record file. To do this, run setup with the settings you need. You only need to do this once.

Use the command prompt to start this installation with the "/r" option (for record):

To run the setup program, open the command prompt as a local administrator and type the following:
setup.exe /r

Setup starts and runs as usual.

Stand-alone license:
When you are prompted to choose the license configuration, select the Use vieweroption.
License server:
When you are prompted to choose the license configuration, select the Use active licenseoption.


Setup logs the entire installation process, writing everything to the setup.iss file.

If you want, you can change the name and folder of this file:

setup.exe /r /f1<folder>:\Setup.iss
For example,
setup.exe /r /f1c:\Setup.iss
This saves the file directly to C:\.

Be careful:
There must not be any blanks between "f1" and the folder!

Copy the setup.iss file to a folder that can be accessed by all clients you want to install. It is a good idea to copy this file to the folder with the Allplan installation files.

License server:
Copy the %AppData%\Nemetschek\Lic3.inifile to the %AppData%\Nemetschek folder of every client.
If you install Allplan on a client for the first time, you must create the Nemetschek folder in %AppData% first (for example, C:\Users\Username\Appdata\Roaming\Nemetschek).


2. Silent installation:
Make sure you can access the setup.iss file.

License server:
Make sure the Lic3.ini file is in the %AppData%\Nemetschek\ folder.


Setup logs the entire installation process again, writing everything to the setup.log file. You can find this file in the same folder as the setup.iss file. With the /f2 option, you can specify a different folder and file name for the setup.log file.

To start installing Allplan in silent mode on a client, open command prompt as a local administrator and type the following:

setup.exe /s /f1<folder>:\Setup.iss /f2<folder>:\Setup.log

For example,
setup.exe /s /f1c:\Setup.iss /f2c:\Setup.log
This saves the file directly to C:\.

Check the setup.log file to see whether everything has been installed correctly. The [ResponseResult] section should return the &apos;ResultCode=0&apos; value.



Note:

If you have several licenses or license servers, select the required license for each client using the Services application - Utilities - License settings.

Refer to the online help for detailed information on installing in silent mode.
http://help.allplan.com/Allplan/2017-0/1031/Allplan/index.htm#321.htm
To open the help system, press the F1 key during setup. Go to the "Contents" tab, select "Installing" and then "Installing in silent mode".

You can also find information in the help for the license settings:
Services application -> Utilities -> License settings
To open the help system, press the F1 key. Go to the "Contents" tab, select "Licensing Allplan using a license server" and then "Installing in silent mode".


Please note that we cannot provide support for this installation method.

Загрузка PDF  FAQ_EN_Allplan_silent_installation_(Allplan_2017_and...