Question:

How can I output a test plot with different data types used in Allplan?



Solution:

Allplan comes with drawing files containing test data that can be used for this purpose.

If necessary, create a new project and copy the drawing files with the test data to this new project.

Open ProjectPilot: Allplan -> File -> ProjectPilot - Admin.

Set the external path to the '..\New\Testplot' folder, which is a subfolder of the local Allplan program folder.
Click 'External path' with the right mouse button and, on the shortcut menu, choose 'Select external path'.
Select the '..\New\Testplot' folder, which is a subfolder of the local Allplan program folder: c:\Programs\Nemetschek\Allplan\New\Testplot, for example.

The following layouts and drawing files are available:

  • Layout 1 - Test Plot Allplan Testbild / Allplan Test Layout
  • Layout 2 - Test Plot Muster & Schaffur / Patterns & Hatching
  • Layout 3 - Test Plot Allplan Testbild / Allplan Test Layout
  • Drawing file 25 - Füllflächen + Stifte / Fills + Pens
  • Drawing file 26 - Muster / Patterns (Version 2006 and later)
  • Drawing file 27 - Schraffuren / Hatching (Version 2006 and later)
  • Drawing file 100 - Allplan Test Drawing File (Version 2008 and later)


Copy these layouts and drawing files to the new project.
Select the relevant drawing files with the right mouse button and choose 'Copy to ...' on the shortcut menu.
Select the new project.

If necessary, create a layout, place the drawing files in this layout, specify an output device and and print the layout.

Note:

Make the following settings to ensure that the data is output correctly:

  • Select "white" for the background color.
  • Turn off "Color stands for pen" in "Show/Hide".
  • Turn off "Surface elements in background of each document" on the "Selection" tab of "Plot Layouts".
  • Use Windows drivers for printing.
  • For HP plotters, select the "Avoid out of memory condition" or "Output as a bitmap" option in the plotter properties.
  • For optimum color output with sRGB values, apply the settings described in the FAQ entitled Color adjustment - Windows drivers and Nemetschek vector drivers.
    https://connect.allplan.com/en/faqid/0001a106.html



Notes:

Colors in printouts can vary depending on several factors such as

  • Output device used
  • Paper used
  • Ink used
  • Driver type used (Windows or Nemetschek drivers)

In particular, colors can differ regarding

  • Color display
  • Brightness


Colors in printouts can even vary if you use the same output device but different Windows drivers.
On-screen display can be influenced by various factors such as different settings for contrast and color temperature.

As the possible settings are so widespread, you can see that it is essential to print out test data in advance.

Загрузка PDF  FAQ_EN_Printing_test_plots.pdf
Версия:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Последнее изменение: 17.12.2015
 

Question:

After I have installed Allplan, the program no longer accepts the parallel dongle connected to the computer. Allplan starts as a viewer.
What can I do?



Answer:

The dongle query changed with Allplan 2013. The dongles causing these problems are usually parallel dongles that are connected to a port (LPT3) that was added later.

Determine the I/O range of the LPT port:

Open the Control Panel and then the Device Manager.

  • Select "Ports -> ECP Printer Port" for a direct parallel port.
  • Select "Multifunction adapter" and the corresponding port for a parallel adapter (e.g., SUNIX).


Properties -> Resources

Note down the first value in the first line below resource settings.

For example:

Resource typeSetting
I/O range0378 – 037F
I/O range0778 – 077F



In this example, the value is 0378.

Open Allplan's license settings:
Services application -> Utilities -> License -> License Settings

Switch to:
License check tab -> Specify searching order ... (or environment variable...)

Enter theI/O value followed by a "p"in the "HL_SEARCH=..." box. For example,
0378p

Click "OK" and then "Apply".


Загрузка PDF  FAQ_EN_Parallel_dongle_is_no_longer_accepted_after_i...
Версия:  Allplan 2016  | Последнее изменение: 30.11.2017
 

Question:

Can I "automate" the installation of Allplan?


Answer:

You can install Allplan 2016 in silent mode. This installation mode is fully automatic; you do not need to enter anything. Silent installation is particularly useful if you want to install Allplan 2016 with the same settings on a large number of workstations on a network.

You can only install in silent mode if ...

  • You take the licenses for the clients from a license server.
  • You have installed the license server.
  • You have activated the license of the license server.

For more information on the license server, go to https://connect.allplan.com/en/faqid/20150618084450.html

Some more tips:

  • Before you start installing, unzip the Allplan installation package (for example, using the 7_Zip program) and make sure this package is in a folder that can be accessed by all the clients you want to install.
  • Start the command prompt for running the setup program always as a local administrator. To do this, open the shortcut menu and select "Run as administrator".
  • Setup will automatically install any Microsoft components required by Allplan such as Microsoft .NET-Framework or Microsoft Report Viewer without prompting you to confirm.




Installing in silent mode involves three steps:

Creating the log file for installing in silent mode

Start by installing Allplan 2016 with the /r option on a typical workstation. During installation, Setup automatically writes all entries to a log file named setup.iss. You can then use this file to install the program on the other workstations.

Installing in silent mode

Next, install Allplan with the /s option on all other workstations. Installation is based on the setup.iss log file you created in the first step.

Checking the installation

Finally, you should check the setup.log file, which was created automatically during setup, to see whether everything was installed correctly.

Note: When installing in silent mode, Setup usually uses the same setup.iss file to install the program on all workstations. However, you can edit some settings of the setup.iss file if you want to adjust paths. For more information, see Adjusting the setup.iss file.

To install Allplan in silent mode, do the following:


1. First installation:
Start by creating a record file. To do this, run setup with the settings you need. You only need to do this once.
Setup writes the license settings to the %AppData%\Nemetschek\Lic3.ini file.
Use the command prompt to start this installation with the "/r" option (for record):

To run the setup program, open the command prompt as a local administrator and type the following:
setup.exe /r

Setup starts and runs as usual.

When you are prompted to choose the license configuration, select the Use active licenseoption.

Setup logs the entire installation process, writing everything to the setup.iss file.

If you want, you can change the name and folder of this file:

setup.exe /r /f1<folder>:\Setup.iss
For example:
setup.exe /r /f1c:\Setup.iss
In this case, the file is saved directly to C:\.

Be careful:
enter "f1" and the folder without any blanks!

Copy the %AppData%\Nemetschek\Lic3.inifile to the %AppData%\Nemetschek folder of every client.
If you install Allplan on a client for the first time, you need to create the Nemetschek folder in %AppData% first (for example, C:\Users\Username\Appdata\Roaming\Nemetschek).

2. Silent installation:

Check that the Lic3.ini file is in the %AppData%\Nemetschek\ folder and that setup can access the setup.iss file.

Setup logs the entire installation process again, writing everything to the setup.log file. You can find this file in the same folder as the setup.iss file. With the /f2 option, you can specify a different folder and file name for the setup.log file.

To start installing Allplan in silent mode on a client, open command prompt as a local administrator and type the following:

setup.exe /s /f1<folder>:\Setup.iss/f2<folder>:\Setup.log

For example:
setup.exe /s /f1c:\Setup.iss/f2c:\Setup.log
In this case, the file is saved directly to C:\.

Check the setup.log file to see whether everything has been installed correctly. The [ResponseResult] section should return the &apos;ResultCode=0&apos; value.


Note:

If you have several licenses or license servers, select the required license for each client using the Services application - Utilities - License settings.

Refer to the online help for detailed information on installing in silent mode.
To open the help system, press the F1 key during setup. Go to the "Contents" tab, select "Installing" and then "Installing in silent mode".

You can also find information in the help for the license settings:
Services application -> Utilities -> License settings
To open the help system, press the F1 key. Go to the "Contents" tab, select "Licensing Allplan using a license server" and then "Installing in silent mode".


Please note that we cannot provide support for this installation method.

Загрузка PDF  FAQ_EN_Allplan_silent_installation_(Allplan_2016_and...
Версия:  Allplan 2017  | Последнее изменение: 08.05.2019
 

Question:

What license issues do I need to consider when upgrading from Allplan 2014/2015/2016 to Allplan 2017?



Answer:

Allplan 2016 introduced a new protection system. Since then licensing has been based on CodeMeter by Wibu Systems AG. Allplan 2017 uses this protection system, too.




1. Upgrading stand-alone workstations

1a. Stand-alone workstation - upgrading from Allplan 2016
The license for Allplan 2017 updates automatically. Start Setup and follow the instructions displayed. When you are prompted to select the license file, click 'Use active license'.
Follow the installation instructions.

Note: The licenses only update automatically when you upgrade. To install Allplan 2017 on a new computer, please read the following instructions: https://connect.allplan.com/en/faqid/20150618131629.html

You can find your Product Key in Allplan Connect as usual. Go to http://connect.allplan.com/license

1b. Stand-alone workstation - upgrading from Allplan 2014 or 2015
Start Setup and follow the instructions displayed. When you are prompted to select the license file, click 'License activation'. Enter your Product Key (26-digit code) and click 'Activate license'. By activating your license, you connect it with your computer. Follow the installation instructions.
You can find detailed information at
https://connect.allplan.com/en/faqid/20150618130717.html





2. Upgrading license server workstations

2a. License server workstations - upgrading from Allplan 2016
Start by updating your license(s) at the license server. After this, upgrade the clients.

Check the version of the license server. If you use the license server 2016-1-4 or later, you can find the version number (Build-ID) at bottom left in the License Settingsprogram. The version number should be at least 1.614.x.x. If you cannot see the Build-ID, you work with an older license server. In this case, update the license server first. Download the software for the license server from Allplan Connect.

You can find detailed information at
https://connect.allplan.com/en/faqid/20160527114300.html

After having updated the licenses, you can upgrade Allplan at the clients. Start Setup and follow the instructions displayed. The license server license will be detected automatically on the network. When you are prompted to select the license file, click 'Use active license'. Follow the installation instructions.

Note: You can update the licenses only at a license server you have already installed. If you want to switch to Allplan 2017 and move the license server to a new server, please read the following instructions:
https://connect.allplan.com/en/faqid/20150618134224.html
You can find your Product Key for Allplan 2016 in Allplan Connect as usual. Go to http://connect.allplan.com/license

2b. License server workstations - upgrading from Allplan 2014 or 2015

Start by installing the license server. After this, upgrade the clients.
You can find detailed information at
https://connect.allplan.com/en/faqid/20150618084450.html


Downloading licenses from Allplan Connect

You can find your license for Allplan 2014 BCM and the activation code for Allplan 2017 IBDin Allplan Connect. As an extra servicewe provide the old licenses for hardlock stand-alone workstations, the temporary licenses for NemSLock and the Product Keys for the new software protection system. Click
Profile > License administration.
Only administrators can use this function.